        • Mid-term effectiveness of arthrolysis and hinged external fixation for treatment of stiff elbow caused by heterotrophic ossification

          ObjectiveTo evaluate the mid-term effectiveness of arthrolysis and hinged external fixation for the treatment of stiff elbow caused by heterotrophic ossification.MethodsBetween January 2014 and December 2017, 11 patients with stiff elbow caused by heterotrophic ossification were admitted. There were 9 males and 2 females with an average age of 32 years (range, 14-48 years), and left side in 6 cases and right side in 5 cases. The cause of stiff elbow included humerus fracture in 5 cases, ulna fracture in 2 cases, fracture of capitulum radii in 1 case, dislocation of capitulum radii in 1 case, terrible triad of the elbow in 1 case, and soft tissue injury in 1 case. The disease duration ranged from 7 to 18 months (mean, 11 months). Preoperative active range of motion of elbow was (19.6±17.5)° and Mayo score was 34.1±9.7. All patients received the treatment of arthrolysis and debridement of heterotrophic ossification lesion combining hinged external fixator, and active and passive rehabilitation with the help of hinged external fixator. The hinged external fixators were removed after 2 months.ResultsAll patients were followed up 13-36 months (mean, 19.1 months). All incisions healed by first intention, and no complication of infection or nerve lesion occurred postoperatively. At last follow-up, the results of X-ray films showed that no heterotrophic ossification recurred. The active range of motion of elbow was (116.4±16.6)° and Mayo score was 93.2±7.8, showing significant differences when compared with preoperative ones (t=17.508, P=0.000; t=16.618, P=0.000).ConclusionThe application of arthrolysis and debridement of heterotrophic ossification lesion combining hinged external fixator can improve the elbow’s range of motion significantly and obtain a good mid-term effectiveness.

          Release date:2019-09-18 09:49 Export PDF Favorites Scan
        • Mid-term effectiveness of anterior cruciate ligament revision

          ObjectiveTo assess the mid-term effectiveness of anterior cruciate ligament (ACL) revision and to analyze the relevant factors that may affect the surgical outcomes.MethodsThe clinical data of 24 patients who underwent ACL revision surgery between April 2009 and July 2018 and were followed up for more than 2 years were retrospectively analyzed. There were 20 males and 4 females with a median age of 30 years [interquartile distance (IQR) was (25, 36) years]. The median body mass index was 24.45 kg/m2 and IQR was (22.93, 25.93) kg/m2. The median time between ACL revision and reconstruction was 41 months and IQR was (15, 85) months. The direct cause of the failure of reconstruction surgery included 14 cases of trauma, 8 cases of no obvious cause, and 2 cases of infection. During the revision operation, 14 patients had a poor bone tunnel position, all of which were drilled with new tunnels, the remaining 10 patients were freshly modified on the basis of the original bone tunnel. Seventeen patients used autogenous tendon revision, 7 patients used LARS ligament; 16 patients had cartilage injury. The Lysholm score, the International Knee Documentation Committee (IKDC) score, and the Tegner sports rating score were used for functional evaluation before operation, at 1 year after operation, and at last follow-up. The Likert satisfaction score was recorded at last follow-up.ResultsPatients were followed up with a median time of 47 months and IQR was (32, 61) months. The Lysholm score, IKDC score, and Tegner sports rating score were significantly improved at 1 year after operation and at last follow-up when compared with preoperative scores (P<0.05). There was no significant difference between at last follow-up and at 1 year after operation (P>0.05). At last follow-up, the median Likert satisfaction score was 4.0 and IQR was (3.0, 4.5). According to the presence or absence of cartilage damage and the type of graft, the above scores at last follow-up were compared between the groups, and the differences were not significant (P>0.05). At last follow-up, 2 patients had graft fractures due to trauma again, and autogenous iliac bones were taken to fill the bone tunnel, and the second stage was revised; the rest of the patients recovered satisfactorily.ConclusionWith preoperative identification of the cause of ACL reconstruction failure, the stability and function of knee joint can be significantly improved by selecting appropriate bone tunnels and grafts during the revision and by active rehabilitation exercises.

          Release date:2021-01-29 03:56 Export PDF Favorites Scan
        • Mid-term effectiveness of arthroscopic Bankart repair in treatment of recurrent anterior shoulder dislocation

          Objective To investigate the mid-term effectiveness of arthroscopic Bankart repair for recurrent anterior shoulder dislocation. Methods The clinical data of 107 patients with recurrent anterior shoulder dislocation who met the inclusion criteria between January 2017 and June 2021 was retrospectively analyzed, and all patients underwent arthroscopic Bankart repair. There were 88 males and 19 females. The age of the primary dislocation ranged from 13 to 48 years (mean, 23.3 years). The number of preoperative dislocations was 2-160 times (median, 7 times). The duration of preoperative instability was 0.2-240.0 months (median, 36.0 months). The mean age at operation was 28.2 years (range, 16-61 years). There were 43 cases of left shoulder and 64 cases of right shoulder. The proportion of glenoid defects in 63 patients was 1.7%-16.1% (mean, 8.1%). MRI showed that none of the patients had rotator cuff tears or shoulder stiffness. The CT three-dimensional reconstruction was performed at 1 day after operation to evaluate the distribution of implanted anchors and the occurrence of glenoid split fracture and whether there were nails pullout at the implant site. The postoperative complications were observed, and the pain and function of the shoulder were evaluated by visual analogue scale (VAS) score, Rowe score, Constant-Murley score, and American Shoulder and Elbow Surgeons (ASES) score. The recurrence of instability, the results of apprehension test, the number of patients who returned to preoperative sports level, and the satisfaction rate of patients were recorded. Results All patients were successfully operated and were followed up 20-73 months (mean, 41.5 months). All incisions healed by first intention. The CT three-dimensional reconstruction at 1 day after operation showed that the anchors were located at the 2 : 00-5 : 30 positions of the glenoid, and there was no glenoid split fracture or nails pullout at the implant site. At last follow-up, VAS score was significantly lower than that before operation, and Rowe score, Constant-Murley score, and ASES score were significantly higher than those before operation (P<0.05). Seven patients (6.5%) had recurrence of anterior shoulder dislocation at 23-55 months (mean, 39.9 months) after operation, including 6 cases of dislocation and 1 case of subluxation. At last follow-up, 51 patients (47.7%) returned to preoperative sports level, and 11 patients (10.3%) had a positive apprehension test. The patients’ satisfaction rate was 90.7% (97/107). Among the 10 patients who were not satisfied with the surgical effectiveness, 7 patients had postoperative recurrence of instability, and 3 patients felt that they did not return to preoperative sports level. Conclusion Arthroscopic Bankart repair has good mid-term effectiveness in patients with recurrent anterior shoulder dislocations, minimal or no glenohumeral bone defects and low sports need.

          Release date:2023-05-11 04:44 Export PDF Favorites Scan
        • Mid-term effectiveness of manipulation under anesthesia combined with arthroscopic capsular release and subacromial debridement for primary frozen shoulder

          ObjectiveTo evaluate mid-term effectiveness of manipulation under anesthesia combined with arthroscopic capsular release and subacromial debridement for primary frozen shoulder.MethodsBetween January 2013 and December 2017, 33 patients of primary frozen shoulder were treated with manipulation under anesthesia combined with 360° arthroscopic capsular release and subacromial debridement. There were 10 males and 23 females, aged from 37 to 65 years, with a mean age of 50.9 years. The affected shoulder on left side in 17 cases and on right side in 16 cases. The disease duration was 6-13 months (mean, 8.4 months). Before and after operation, the visual analogue scale (VAS) score was used to evaluate the shoulder joint pain, Constant score was used to evaluate the shoulder joint function, and the flexion, abduction, and external rotation of shoulder joint were recorded. The internal rotation function was assessed based on the vertebral plane that the thumb could reach after internal rotation of the affected shoulder joint (the rank of internal rotation vertebra). X-ray film was taken to measure the distance of the subacromial space.ResultsThere was no fracture or labrum tear in all patients, and all the incisions healed by first intention. All the 33 patients were followed up 20-31 months, with an average of 24.1 months. During the follow-up, there was no complication such as wound infection and nerve injury. At last follow-up, the range of motion of shoulder flexion, abduction, and external rotation, the rank of internal rotation vertebra, the VAS score, Constant score, and subacromial space were significantly improved when compared with preoperative ones (P<0.05).ConclusionManipulation under anesthesia combined with arthroscopic capsular release and subacromial debridement can achieve a good mid-term effectiveness without complication for primary frozen shoulder.

          Release date:2020-07-07 07:58 Export PDF Favorites Scan
        • Mid-term effectiveness of modified arthroscopic suture button fixation Latarjet procedure for treatment of recurrent anterior shoulder dislocations

          Objective To summarize mid-term effectiveness of modified arthroscopic suture button fixation Latarjet procedure for treatment of recurrent anterior shoulder dislocations. Methods Between January 2018 and October 2020, 30 patients with recurrent anterior shoulder dislocations were treated with modified arthroscopic suture button fixation Latarjet procedure. There were 19 males and 11 females with an average age of 27.3 years (range, 18-41 years). The shoulder dislocation occurred 3-7 times, with an average of 4.9 times. The time from the last dislocation to operation was 3-10 days, with an average of 4.1 days. Glenoid defects exceeded 20% in all cases. There were 27 cases of Hill-Sachs lesions. The joint pain and function were estimated by visual analogue scale (VAS) score, University of California, Los Angeles (UCLA) score, Rowe score, American Association for Shoulder and Elbow Surgery (ASES) score, Walch-Duplay score, and the range of external rotation at 0° and external rotation at 90° abduction of shoulder before operation and at 1 month, 6 months, and last follow-up. The X-ray film, CT scan and three-dimensional reconstruction were reviewed to observe the position, healing, and absorption of the coracoid graft, correction of glenoid defect, and joint degeneration.Results The operation time ranged from 51 to 79 minutes, with an average of 68.4 minutes. All incisions healed without complications such as nerve or blood vessel injury. All patients were followed up 36-60 months with an average of 44.6 months. The VAS score, UCLA score, Rowe score, ASES score, Walch-Duplay score, and the range of external rotation at 0° and external rotation at 90° abduction after operation significantly improved when compared with preoperative values (P<0.05). All indicators further improved with time, and the differences between different time points after operation were significant (P<0.05). Imaging review showed that the coracoid graft was located in the anteroinferior glenoid at 1 day after operation, and no occurrence of shoulder osteoarthritis was found during follow-up. The anatomical structure of the glenoid was normal, and no delayed healing or non-union of the coracoid graft occurred. At 20 months after operation, arthroscopic re-exploration was performed in 1 case due to fracutre caused by falling injury revealed the good shaping of the coracoid graft, smooth glenoid, and no bone resorption or osteoarthritis. ConclusionFor recurrent anterior shoulder dislocations, the modified arthroscopic suture button fixation Latarjet procedure can obtain good recovery of shoulder function and low incidence of complications and has a good mid-term effectiveness.

          Release date:2024-06-14 09:52 Export PDF Favorites Scan
        • Mid-term effectiveness of LU-tarjet procedure for recurrent anterior shoulder dislocation

          Objective To evaluate the mid-term effectiveness of limited unique coracoid osteotomy suture button fixation Latarjet (LU-tarjet) procedure in treatment of recurrent anterior shoulder dislocation. Methods Between March 2017 and February 2019, 56 patients with recurrent shoulder dislocation were treated with arthroscopic LU-tarjet procedure. There were 44 males and 12 females with an average age of 26.3 years (range, 18-41 years). Shoulder joint dislocation occurred 2-16 times, with an average of 7.5 times. The time from the initial dislocation to operation ranged from 6 months to 13 years, with a median of 4.6 years. Preoperative shoulder joint fear test and re-reduction test were positive in all patients. The Beighton score of joint relaxation ranged from 1 to 7, with an average of 4.1. The shoulder Instability Severity Index Score (ISIS) ranged from 5 to 10, with an average of 7.8. The size of glenoid defects on the affected side ranged from 15% to 32% (mean, 22.4%). All patients had Hill-Sachs injuries of varying degrees. Six patients had re-dislocation after Bankart surgery. The operation time, incision healing, and postoperative complications were recorded. The range of motion (shoulder flexion, extension, abduction, external rotation, 90° external rotation, and internal rotation) and muscle strength in shoulder flexion, abduction, external rotation, and internal rotation) of shoulder joint were compared between pre- and post-operation. The improvement of shoulder function was evaluated using the American Association for Shoulder and Elbow Surgery (ASES) score, Walch-Duplay score, and Rowe score. X-ray films and three-dimensional CT were used to analyze the location, healing, and remolding of bone graft, the repair of glenoid defect, and degenerative changes of the shoulder joint. Results All operations were successfully completed. The operation time ranged from 42 to 98 minutes, with an average of 63 minutes. All incisions healed by first intention. All patients were followed up 5-7 years (mean, 6.3 years). During follow-up, 2 patients experienced shoulder subluxation within 1 year after operation and 1 patient experienced recurrent shoulder joint pain. The remaining patients had no related complications. At last follow-up, there was no significant difference between the two groups (P>0.05) in range of motion (shoulder flexion, extension, abduction, external rotation, 90° external rotation, and internal rotation) and muscle strength in shoulder flexion, abduction, external rotation, and internal rotation). The ASES score, Rowe score, and Walch-Duplay score of shoulder significantly improved when compared with those before operation (P<0.05). Postoperative CT showed that 53 cases (94.64%) of coracoid bone masses were centered placed vertically, 2 cases (3.57%) were superior, and 1 case (1.79%) was inferior; 49 cases (87.50%) of the coracoid bone grafts were flush with the glenoid, 2 cases (3.57%) and 5 cases (8.93%) were medially and laterally positioned. The volume of coracoid bone graft decreased first and then increased, and the shape of the bone graft was continuously remodeling and gradually matched with the track of the humerus head (the optimal circle of the glenoid), all coracoid bone grafts healed. At last follow-up, the coverage rate of optimal glenoid circle was 89.6%-100%, with an average of 97.4%. The area of glenoid defect was 2.6%±1.3%, which significantly decreased when compared with preoperative (22.4%±5.4%) (P<0.05). At last follow-up, no obvious degenerative changes of shoulder joint was observed. ConclusionLU-tarjet procedure for recurrent anterior shoulder dislocation has good mid-term effectiveness with short operation time and few complications.

          Release date: Export PDF Favorites Scan
        • Mid-term effectiveness analysis of combined knee extensor mechanism realignment with bone anchor for recurrent patella dislocation

          Objective To explore the mid-term effectiveness of combined knee extensor mechanism realignment with bone anchor for recurrent patella dislocation. Methods Between August 2017 and May 2019, 21 patients with recurrent patella dislocation underwent combined knee extensor mechanism realigament with bone anchor and followed up more than 3 years. There were 8 males and 13 females with an average age of 19.4 years (range, 13-26 years). All 21 patients had a history of recurrent patellar dislocation for 2-5 times (median, 3 times), and the disease duration was 1-16 years (mean, 5 years). The preoperative Lysholm score was 67.5±6.3 and the Kujula score was 64.1±7.0. The defect of meniscus, anterior and posterior cruciate ligaments, and medial and lateral collateral ligaments were excluded by MRI examination; CT examination showed that the tibial tuberosity-trochlear groove distance was 2.05-2.56 cm, with an average of 2.16 cm; X-ray examination showed that lower limb force line was abnormal. The effectiveness were evaluated by Lysholm score and Kujula score before operation and at 3 years after operation, and Insall evaluation standard at 3 years after operation. Results All the incisions healed by first intention, and there was no surgical complication such as lower extremity deep vein thrombosis, incision infection, and nerve injury. All 21 patients were followed up 3.0-3.5 years, with an average of 3.2 years. Anteroposterior and lateral X-ray films of the knee joint at 3 years after operation showed that the position of the patella was normal, and the axial X-ray films of the patella (30°, 60°, 90°) showed that the patellofemoral joint had a good relationship. During the follow-up, there was no anchor drop or fracture, no obvious pseudarthrosis formation, and no epiphyseal injury in the minor patients. The Lysholm score was 91.5±7.1 and the Kujula score was 88.1±7.6 at 3 years after operation, which were significantly improved when compared with those before operation (t=11.57, P=0.00; t=12.78, P=0.00). According to the Insall evaluation criteria, 12 cases were excellent, 4 cases were good, 4 cases were fair, and 1 case was poor, with an excellent and good rate of 76.2%. ConclusionCombined knee extensor mechanism realignment with bone anchor is a simple and reliable way to treat the recurrent patella dislocation, with a satisfactory mid-term effectiveness and less complications; however, its long-term effectiveness needs further follow-up.

          Release date:2022-08-29 02:38 Export PDF Favorites Scan
        • Mid-term effectiveness of total hip arthroplasty with subtrochanteric shortening osteotomy in treatment of Crowe type Ⅳ developmental dysplasia of hip

          ObjectiveTo explore the mid-term effectiveness of total hip arthroplasty (THA) with subtrochanteric shortening osteotomy in treatment of Crowe type Ⅳ developmental dysplasia of the hip (DDH).MethodsBetween September 2009 and March 2014, a total of 49 patients (57 hips) who were diagnosed with Crowe type Ⅳ DDH were treated with THA and subtrochanteric shortening osteotomy. Of the 49 patients, 7 were male and 42 were female with an average age of 44.6 years (range, 20-73 years). The preoperative Harris score was 44.68±3.39 and the preoperative leg length discrepancy was (5.27±0.55) cm.ResultsAll incisions healed primarily. All patients were followed up 32-87 months (mean, 52.1 months). At last follow-up, the Harris score was 85.67±2.89 and the leg length discrepancy was (1.12±0.48) cm, showing significant differences when compared with the preoperative values (t=–69.53, P=0.00; t=42.94, P=0.00). X-ray films showed that bone union of the femoral osteotomy end at 6 months after operation. There was no loosening and subsidence of prosthesis at last follow-up.ConclusionThe subtrochanteric shortening osteotomy with THA in treatment of Crowe type Ⅳ DDH can obtain satisfactory mid-term effectiveness with low risk of peripheral vascular and nerve traction injuries.

          Release date:2018-04-03 09:11 Export PDF Favorites Scan
        • Mid-term effectiveness of arthroscopic “mini incision” transtendon repair for partial articular-sided supraspinatus tendon avulsion lesion

          Objective To explore the mid-term effectiveness of arthroscopic “mini incision” transtendon repair for partial articular-sided supraspinatus tendon avulsion (PASTA) lesion. Methods A clinical data of 39 patients with PASTA lesions, who underwent the arthroscopic “mini incision” transtendon repair and met the selected criteria between May 2017 and April 2021, was retrospectively analyzed. There were 13 males and 26 females, with an average age of 63.7 years (range, 43-76 years). Nine patients underwent trauma history, and no obvious inducement was found in the other 30 patients. The main clinical symptom was shoulder pain with positive hug resistance test. The interval from symptom onset to operation was 3-21 months (mean, 8.3 months). The visual analogue scale (VAS) score, University of California Los Angeles (UCLA) shoulder score, American Association of Shoulder and Elbow Surgeons (ASES) score and shoulder range of motion (ROM) of forward flexion, abduction, and external rotation were used to evaluate shoulder function. MRI was performed to assess the structural integrity and tension of reattached tendon. Patient satisfactions were calculated at last follow-up. Results All incisions healed by first intention with no complications such as incision infection or nerve injury. All patients were followed up 24-71 months (mean, 46.9 months). The VAS, UCLA, and ASES scores significantly improved at 24 months after operation when compared with preoperative ones (P<0.05). The ROMs of forward flexion and external rotation of the shoulder joint significantly increased at 3 and 24 months, and further increased at 24 months compared to 3 months, with significant differences (P<0.05). However, the ROM of abduction of the shoulder joint at 3 months did not significantly improve compared with that before operation (P>0.05), and it was significantly greater at 24 months than before operation and at 3 months after operation (P<0.05). At last follow-up, the patients were very satisfied with the effectiveness in 30 cases (76.9%), satisfied in 5 cases (12.8%), and dissatisfied in 4 cases (10.3%). At 6 months after operation, 31 patients underwent reviews of MRI scans, of which 28 patients possessed intact structural integrity, good tendon tension and tendon healing, and 3 patients underwent tendon re-tear. ConclusionArthroscopic “mini incision” transtendon repair in treatment of PASTA lesion could obtain satisfying mid-term effectiveness with low risk of tendon re-tear.

          Release date:2023-06-07 11:13 Export PDF Favorites Scan
        • Mid-term effectiveness of large-head metal-on-metal total hip arthroplasty

          ObjectiveTo explore the mid-term effectiveness of large-head metal-on-metal total hip arthroplasty (THA).MethodsA retrospective analysis was made on the clinical date of 40 patients (43 hips) who were treated with the large-head metal-on-metal THA between April 2009 and June 2010. There were 18 males (20 hips) and 22 females (23 hips) with an average age of 55.1 years (range, 20-85 years). Unilateral hip was involved in 37 cases and bilateral hips in 3 cases. The disease causes included osteonecrosis of the femoral head in 14 cases (15 hips), osteoarthritis in 6 cases (7 hips), rheumatoid arthritis in 4 cases (4 hips), femoral neck fracture in 4 cases (4 hips), and developmental dysplasia of the hip in 12 cases (13 hips). Before operation, the Harris score and University of California Los Angeles (UCLA) score were 38.51±5.62 and 4.21±1.43, respectively. The visual analogue scale (VAS) score was 6.78±0.95.ResultsAll patients were followed up 6.7-8.3 years (mean 7.5 years). All incisions healed primarily and no neurovascular injury, infection, and hip dislocation occurred. At last follow-up, the Harris score and UCLA score were 93.33±3.21 and 7.32±1.45, respectively, showing significant differences when compared with preoperative scores (t=51.753, P=0.000; t=23.232, P=0.000). The thigh pain occurred in 3 cases (3 hips) in whom the inflammatory pseudotumor of soft tissues was found in 1 case (1 hip). Postoperative X-ray films showed that the acetabular abduction angle and anteversion angle were (46.5±3.2)° and (14.8±3.6) °, respectively. The initial stability of femoral stem prosthesis was excellent in 39 hips and good in 4 hips according to Mulliken standard. Osteolysis occurred in 2 hips and revision was performed in 1 hip of secondary loosening of prosthesis. The rest patients had no prosthesis loosening or sinking.ConclusionThe mid-term effectiveness of large-head mental-on-mental THA in treatment of the terminal diseases of hips are good.