Objective To investigate the effectiveness of tunnel osteogenesis technique combined with locking plate in the treatment of aseptic non-hypertrophic nonunion of femoral shaft. MethodsThe clinical data of 23 cases of aseptic non-hypertrophic nonunion of femoral shaft treated with tunnel osteogenesis technique combined with locking plate between January 2017 and December 2020 were retrospectively analysed. There were 17 males and 6 females with an average age of 41.4 years (range, 22-72 years). There were 22 cases of closed fracture and 1 case of open fracture. The types of internal fixation at admission included intramedullary nail in 14 cases and steel plate in 9 cases. The number of nonunion operations received in the past was 0 to 1; the duration of nonunion was 6-60 months, with an average of 20.1 months. Among them, there were 17 cases of aseptic atrophic nonunion of the femoral shaft and 6 cases of dystrophic nonunion. Twenty-two cases were fixed with 90° double plates and 1 case with lateral single plate. The operation time, theoretical blood loss, hospitalization stay, nonunion healing, and postoperative complications were recorded. Harris hip function score, Lysholm knee function score, lower extremity function scale (LEFS), and short-form 36 health survey scale (SF-36) were used at last follow-up to evaluate hip and knee functions. Visual analogue scale (VAS) score was used to evaluate the relief of pain at 1 day after operation and at last follow-up. ResultsThe average operation time was 190.4 minutes, the average theoretical blood loss was 1 458.4 mL, and the average hospitalization stay was 8.2 days. All the 23 patients were followed up 9-26 months, with an average of 18.2 months. The healing time of nonunion in 22 patients was 3-12 months, with an average of 5.6 months. There were 8 cases of limb pain, 8 cases of claudication, 6 cases of limitation of knee joint movement, and 2 cases of limitation of hip joint movement. At last follow-up, the imaging of 1 patient showed that the nonunion did not heal, accompanied by pain of the affected limb, lameness, and limitation of knee joint movement. At 1 day after operation, the VAS score of 23 patients was 6.5±1.8, the pain degree was good in 7 cases, moderate in 12 cases, and poor in 4 cases; at last follow-up, the VAS score was 0.9±1.3, the pain degree was excellent in 21 cases and good in 2 cases, which were significantly better than those at 1 day after operation (t=12.234, P<0.001; Z=–5.802, P<0.001). At last follow-up, the average Harris hip function score of 22 patients with nonunion healing was 94.8, and the good rate was 100%; Lysholm knee function score averaged 94.0, and the excellent and good rate was 90.9%; LEFS score averaged 74.6; SF-36 physical functioning score averaged 85.0 and the mental health score averaged 83.6. ConclusionTunnel osteogenesis technique combined with locking plate in the treatment of aseptic non-hypertrophic nonunion of femoral shaft has a high healing rate and fewer complications, which can effectively relieve pain and improve lower limb function and quality of patients’ life.
ObjectiveTo develop an instrument for sacroiliac joint fixation with less injury and less complications. MethodsFirstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups:group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. ResultsAccording to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P>0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than that in group C, but there was no significant difference between group B and group C (P>0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. ConclusionThe polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw direction. The simulated application test shows satisfactory fixing effect.
ObjectiveTo investigate the effectiveness of anatomical locking plate internal fixation combined with coracoclavicular ligament reconstruction in treatment of the Neer type Ⅱb distal clavicle fractures by comparing with the simple anatomical locking plate internal fixation.MethodsThe clinical data of 40 patients with Neer type Ⅱb distal clavicle fractures who met the criteria between February 2013 and January 2017 were analyzed. Eighteen cases were treated with anatomical locking plate internal fixation and coracoclavicular ligament reconstruction by using a suture anchor (reconstruction group), and 22 cases were treated only with anatomical locking plate internal fixation (non-reconstruction group). There was no significant difference in gender, age, injured side, causes of injury, associated injuries, time from injury to operation between 2 groups (P>0.05). The operation time, medical expense, postoperative coracoclavicular distance, Constant-Murley scores of injured side, and complications were recorded and compared between 2 groups.ResultsAll patients were followed up 12-27 months (mean, 16.3 months). One patient in reconstruction group had superficial wound infection. One patient in non-reconstruction group had pullout of screws from the distal fragment and reduction loss at 1 month postoperatively. The operation time and medical expense in reconstruction group significantly increased when compared with those in non-reconstruction group (P<0.05). All fractures in 2 groups achieved bony union at last follow-up. The rate of coracoclavicular distance increase of injured side in non-reconstruction group was significantly higher than that in reconstruction group (t=2.371, P=0.023). The Constant-Murley scores at 1 month, 3 months after operation, and last follow-up were significantly improved when compared with preoperative values in 2 groups (P<0.05), but no significant difference was observed between 2 groups (P>0.05).ConclusionBoth anatomical locking plate internal fixation with and without coracoclavicular ligament reconstruction can achieve good effectiveness for the Neer type Ⅱb distal clavicle fractures. Therefore, the coracoclavicular ligament reconstruction is not necessary, except for comminuted fractures with the length of lateral fragment less than 1 cm or the patients with poor compliance.
Objective To investigate the tunnel-type open reduction and internal fixation of rib fractures (ORIF) with titanium locking plate in traumatic rib fractures. Methods Clinical data of 10 patients with multiple rib fractures from June 2016 to January 2017 in the Sixth People’s Hospital Affiliated to Shanghai Jiaotong University were analyzed. There were 6 males and 4 males with an average age of 38.5±9.0 years (range, 30–63 years). All patients underwent emergency treatment, chest CT and ultrasound examination before they admitted to the hospital. According to rib fractures and injuries, patients were given the tunnel-type ORIF of rib fractures with titanium locking plates, the chest tube and negative suction drainage. The patients were followed up over three months. Results All patients were cured. There was no complication during follow-up. No wound infection and death occurred. Postoperative three-month follow-up showed that chest pain was significantly relieved without pulmonary atelectasis and pleural effusion or other complications. Conclusion Tunnel-type internal fixation of rib fractures with titanium locking plates is effective, which can quickly restore the stability and integrity of the thorax. Surgical procedure is simple and can get fast postoperative recovery to improve the patient's quality of life.
Objective To evaluate the feasibility and short-term effectiveness of polyaxial locking plate for fixation of femoral neck fracture in the middle-aged and elderly patients. Methods A retrospective analysis was made on the clinical data of 13 patients with femoral neck fracture undergoing fixation with polyaxial locking plates between September 2013 and June 2015 (group A) and 13 patients with femoral neck fracture undergoing fixation with three cannulated screws in the same period (group B). There was no significant difference in gender, age, side, cause of injury, Garden type, type of fracture position, type of Pauwels angle, Singh index, time between injury and operation, and preoperative complications between 2 groups (P>0.05). The femoral neck shortening at 1 year postoperatively, and fracture nonunion, femoral head necrosis, and Harris hip score at last follow-up were compared between 2 groups. Results The follow-up time was (19.23±3.98) months in group A and (18.00±3.61) months in group B, showing no significant difference between 2 groups (t=2.063,P=0.417). No femoral head necrosis occurred in group A, but head necrosis occurred in 1 case of group B, and hemiarthroplasty was performed. There was no significant difference in the rate of femoral head necrosis between 2 groups (χ2=0.000,P=1.000). Bone union was obtained in the other patients of 2 groups. The Harris hip score of group A (85.23±2.95) was significantly higher than that of group B (81.92±3.64) at last follow-up (t=2.064,P=0.018). No infection or internal fixation failure occurred in 2 groups. One case had pain at the outer thigh at 1 month after operation in group A, but pain relief was achieved at 3 months after operation. At 1 year after operation, no femoral neck shortening occurred in group A, but degree I, II, and III femoral neck shortening was observed in 3, 2, and 8 cases of group B, respectively, showing significant difference between 2 groups (Z=–4.714,P=0.000). Conclusion Although fixation with polyaxial locking plate for femoral neck fracture in the middle-aged and elderly patients has similar femoral head necrosis rate to fixation with cannulated screws, it has advantages in preventing neck shortening and improving hip joint function after operation.
ObjectiveTo investigate the effectiveness of limited open reduction via “door-shaft method” and internal fixation with locking plate for two- and three-part fractures of the proximal humerus.MethodsThe clinical data of 64 patients with proximal humeral fractures who were admitted between January 2013 and December 2016 and met the selection criteria were retrospectively analyzed. There were 23 males and 41 females, with an average age of 68.0 years (range, 50-89 years). The injuries were caused by falling in 57 cases, traffic accident in 5 cases, and falling from height in 2 cases. The interval between injury and operation was 1-7 days (mean, 2.1 days). According to Neer classification, there were 28 cases of two-part fractures and 36 cases of three-part fractures. According to the angulation direction of the proximal humeral neck shaft angle, there were 21 cases of adduction fractures and 43 cases of abduction fractures. The fractures were treated with limited open reduction via “door-shaft method” and proximal humerus internal locking systems for internal fixation. The operation time, intraoperative blood loss, number of fluoroscopy, hospital stay, and complications were recorded. The fracture healing was reviewed by X-ray film and the healing time was recorded. The shoulder joint function was evaluated by Neer score standard.ResultsThe operation time was 45-127 minutes, with an average of 82.3 minutes. The intraoperative blood loss was 30-125 mL, with an average of 62.7 mL. Intraoperative fluoroscopy was performed 30-69 times, with an average of 37.0 times. The hospital stay was 6-23 days, with an average of 10.3 days. All incisions healed by first intention. All patients were followed up 12-37 months, with an average of 18.3 months. X-ray film re-examination showed that all fractures healed, the healing time was 12-21 weeks, with an average of 14.3 weeks. After operation, 3 cases had shoulder stiffness and 1 case had fracture malunion. At last follow-up, the Neer score of shoulder joint function was 49-97, with an average of 83.1. Among them, 38 cases were excellent, 13 cases were good, 10 cases were fair, and 3 cases were poor. The excellent and good rate was 79.7%. The excellent and good rate of patients with two-part fractures was 82.1% (23/28), and the excellent and good rate of patients with three-part fractures was 77.8% (28/36).ConclusionThe “door-shaft method” not only reduces the difficulty of the Joystick technique in the reduction of proximal humerus fractures, but also provides auxiliary stability. It is used for limited open reduction and internal fixation with locking plate to treat the two- and three-part fractures of the proximal humerus, which can achieve good effectiveness.
Objective To investigate the effectiveness of a new hook-shaped anatomical locking plate in the treatment of Danis-Weber type A lateral malleolus fractures. Methods A retrospective analysis was performed on the clinical data of 45 patients with Danis-Weber type A lateral malleolus fractures who met the selection criteria between November 2020 and November 2022. According to the surgical methods, they were divided into the observation group (treated with the new hook-shaped anatomical locking plate, 23 cases) and the control group (treated with the conventional lateral malleolus anatomical locking plate, 22 cases). There was no significant difference in baseline data such as gender, age, cause of injury, Danis-Weber type of fracture, time from injury to operation, and combined ligament injury between the two groups (P>0.05). The operation time, partial weight-bearing time, return to work time, and postoperative complications were recorded and compared between the two groups. The function and pain of ankle joint were evaluated by the range of motion of ankle dorsiflexion, plantarflexion, varus, valgus, and visual analogue scale (VAS) score at 1 and 3 months after operation, and at last follow-up, and the American Orthopaedic Foot and Ankle Society (AOFAS) score at 3 months after operation and at last follow-up. Results All patients were followed up 10-18 months (mean, 15.1 months). There was no significant difference in operation time between the two groups (P>0.05); the postoperative partial weight-bearing time and return to work time of the observation group were significantly earlier than those of the control group (P<0.05). During the follow-up, there was 1 case of joint stiffness in the observation group, and 1 case of joint surface displacement, 1 case of joint stiffness, and 1 case of traumatic arthritis in the control group. There was no significant difference in the incidences of complications between the two groups (P>0.05). With the extension of time after operation, the range of motion of ankle dorsiflexion, plantarflexion, varus, valgus, and VAS score of the two groups gradually improved, and there were significant differences between different time points (P<0.05); At 1 and 3 months after operation, the above indexes in the observation group were significantly better than those in the control group (P<0.05), and there was no significant difference between the two groups at last follow-up (P>0.05). The difference of AOFAS score between the last follow-up and 3 months after operation in the observation group was significantly better than that in the control group (P<0.05). ConclusionCompared with the conventional lateral malleolus anatomical locking plate, the new hook-shaped anatomical locking plate has a more reliable fixation effect in the treatment of Danis-Weber type A lateral malleolus fracture, which is conducive to early functional exercise of the ankle joint, so that patients can bear weight earlier and return to work earlier, and the operation time is not significantly prolonged, and the effectiveness is satisfactory.
Objective To establish the finite element model of Y-shaped patellar fracture fixed with titanium-alloy petal-shaped poly-axial locking plate and to implement the finite element mechanical analysis. Methods The three-dimensional model was created by software Mimics 19.0, Rhino 5.0, and 3-Matic 11.0. The finite element analysis was implemented by ANSYS Workbench 16.0 to calculate the Von-Mises stress and displacement. Before calculated, the upper and lower poles of the patella were constrained. The 2.0, 3.5, and 4.4 MPa compressive stresses were applied to the 1/3 patellofemoral joint surface of the lower, middle, and upper part of the patella respectively, and to simulated the force upon patella when knee flexion of 20, 45, and 90°. Results The number of nodes and elements of the finite element model obtained was 456 839 and 245 449, respectively. The max value of Von-Mises stress of all the three conditions simulated was 151.48 MPa under condition simulating the knee flexion of 90°, which was lower than the yield strength value of the titanium-alloy and patella. The max total displacement value was 0.092 8 mm under condition simulating knee flexion of 45°, which was acceptable according to clinical criterion. The stress concentrated around the non-vertical fracture line and near the area where the screws were sparse. Conclusion The titanium-alloy petal-shaped poly-axial locking plate have enough biomechanical stiffness to fix the Y-shaped patellar fracture, but the result need to be proved in future.
Objective To evaluate the effectiveness of bridging fixation with long locking plate for displaced midshaft clavicular fractures. Methods Between October 2010 and December 2011, 18 patients with displaced midshaft clavicular fracture were treated with reduction and bridging fixation with 9 or 10 holes locking plate. There were 17 males and 1 female with an average age of 47 years (range, 23-82 years). Fracture was caused by traffic accident in 6 cases, by falling in 10 cases, by crushing in 1 case, and by crashing object in 1 case. All fractures were closed and displaced or shortened (range, 2.1-3.4 cm; mean, 2.62 cm) with angulation deformity. According to Robinson classification criteria, 5 cases were rated as type 2B1 and 13 as type 2B2. The duration from injury to surgery was 5 hours to 19 days (mean, 5 days). The fracture healing time and complication were recorded; the effectiveness evaluation was performed with Constant-Murley score and satisfaction to appearance. Results No neurologic or vascular complication occurred with primary healing of incision. All patients were followed up 12-22 months (mean, 14.7 months). The fracture healing time was 9-14 weeks (mean, 11.4 weeks). During follow-up, no loosening or breakage of internal fixator was observed. The Constant-Murley score was 82-98 (mean, 92.4) at last follow-up; the satisfaction rate of appearance was 88.9% (16/18). Conclusion Bridging fixation with long locking plate is an effective method for treatment of displaced midshaft clavicular fractures. Preserved blood supply and stable angle are important to fracture healing.
ObjectiveTo review the research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate. MethodsThe domestic and foreign literature about the proximal humeral fracture treated with locking plate was extensively reviewed. The incidence of screw penetration and risk factors were summarized from both primary and secondary screw penetrations, and the reasons of the intra-articular screw penetration and the technical solutions to avoid the penetration were analyzed. ResultsThe incidence of intra-articular screw penetration is about 11%-30%, which includes primary and secondary screw penetrations. The primary screw penetration is related to improper operation, inaccurate measurement, and “Steinmetz solid” effect, which results in inadequate fluoroscopy and blind zone. The secondary screw penetration is related to the loss of reduction and varus, collapse, and necrosis of the humeral head. The risk factors for intra-articular screw penetration include the bone mass density, the fracture type, the quality of fracture reduction, the applied location, number, and length of the plate and screws, and whether medial column buttress is restored. Improved fracture reduction, understanding the geometric distribution of screws, good intraoperative fluoroscopy, and reconstruction of medial column buttress stability are the key points for success. ConclusionThe risk of the intra-articular screw penetration in the proximal humeral fractures treated with locking plates is still high. Follow-up studies need to further clarify the cause and mechanism of screw penetration, and the risk factors that lead to screw penetration, in order to effectively prevent the occurrence of this complication.