• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "locking plate" 30 results
        • A finite element analysis of petal-shaped poly-axial locking plate fixation in treatment of Y-shaped patellar fracture

          Objective To establish the finite element model of Y-shaped patellar fracture fixed with titanium-alloy petal-shaped poly-axial locking plate and to implement the finite element mechanical analysis. Methods The three-dimensional model was created by software Mimics 19.0, Rhino 5.0, and 3-Matic 11.0. The finite element analysis was implemented by ANSYS Workbench 16.0 to calculate the Von-Mises stress and displacement. Before calculated, the upper and lower poles of the patella were constrained. The 2.0, 3.5, and 4.4 MPa compressive stresses were applied to the 1/3 patellofemoral joint surface of the lower, middle, and upper part of the patella respectively, and to simulated the force upon patella when knee flexion of 20, 45, and 90°. Results The number of nodes and elements of the finite element model obtained was 456 839 and 245 449, respectively. The max value of Von-Mises stress of all the three conditions simulated was 151.48 MPa under condition simulating the knee flexion of 90°, which was lower than the yield strength value of the titanium-alloy and patella. The max total displacement value was 0.092 8 mm under condition simulating knee flexion of 45°, which was acceptable according to clinical criterion. The stress concentrated around the non-vertical fracture line and near the area where the screws were sparse. Conclusion The titanium-alloy petal-shaped poly-axial locking plate have enough biomechanical stiffness to fix the Y-shaped patellar fracture, but the result need to be proved in future.

          Release date:2017-12-11 12:15 Export PDF Favorites Scan
        • Effectiveness of bone transport with a locking plate versus conventional bone transport for tibial defects

          ObjectiveTo investigate the effectiveness difference between bone transport with a locking plate (BTLP) and conventional bone transport with Ilizarov/Orthofix fixators in treatment of tibial defect. MethodsThe clinical data of 60 patients with tibial fractures who met the selection criteria between January 2016 and September 2020 were retrospectively analyzed, and patients were treated with BTLP (BTLP group, n=20), Ilizarov fixator (Ilizarov group, n=23), or Orthofix fixator (Orthofix group, n=17) for bone transport. There was no significant difference in gender, age, cause of injury, time from injury to admission, length of bone defect, tibial fracture typing, and comorbidities between groups (P>0.05). The osteotomy time, the retention time of external fixator, the external fixation index, and the occurrence of postoperative complications were recorded and compared between groups. The bone healing and functional recovery were evaluated by the Association for the Study and Application of the Method of Ilizarov (ASAMI) criteria. Results All patients of 3 groups were followed up 13-45 months, with a mean of 20.4 months. The osteotomy time was significantly shorter in the BTLP group than in the Ilizarov group, and the retention time of external fixator and the external fixation index were significantly lower in the BTLP group than in the Ilizarov and Orthofix groups (P<0.05). Twenty-two fractures healed in the Ilizarov group and 1 case of delayed healing; 16 fractures healed in the Orthofix group and 1 case of delayed healing; 18 fractures healed in the BTLP group and 2 cases of delayed healing. There was no significant difference between groups in fracture healing distribution (P=0.824). After completing bone reconstruction treatment according to ASAMI criteria, the BTLP group had better bone healing than the Orthofix group and better function than the Ilizarov groups, showing significant differences (P<0.05). Postoperative complications occurred in 4 cases (20%) in the BLTP group, 18 cases (78%) in the Ilizarov group, and 12 cases (70%) in the Orthofix group. The incidence of complication in the BTLP group was significantly lower than that in other groups (P<0.05). Conclusion BTLP is safe and effective in the treatment of tibial defects. BTLP has apparent advantages over the conventional bone transport technique in osteotomy time, external fixation index, and lower limb functional recovery.

          Release date:2022-08-29 02:38 Export PDF Favorites Scan
        • EFFECTIVENESS OF T-LOCKING PLATE FOR INTERNAL FIXATION OF MEDIAL CLAVICLE FRACTURE

          To investigate the effectiveness of T-locking plate in treating medial clavicle fracture so as to find out a therapy with safety and stabil ity. Methods Between October 2006 and January 2009, 13 patients with medial clavicle fracture were treated with open reduction and T-locking plate fixation. There were 9 males and 4 females, aged 18-68 years (mean, 47 years), including 7 cases of traffic accident injury, 4 cases of fall ing injury from height, and 2 cases of heavy object hit injury. The locations were left side in 5 cases and right side in 8 cases. All cases were closed fracture. The disease duration was 1 hour to 14 days. Results All incisions healed by first intention after operation. The X-ray films showed good reduction of fracture and internal fixation. All the 13 patients were followed up 12-18 months (mean, 15 months). The average fracture heal ing duration was 8 weeks (range, 6-12 weeks). No compl ication of infection, nerve or blood vessel injury, hemopneumothorax, or internal fixation loosening or failure occurred. The anatomical medial clavicle structure as well asappearances and functions were restored. According to Rockwood’s score method, the results were excellent in 11 cases and good in 2 cases. Conclusion The internal fixation of T-locking plate in treating medial clavicle fracture has the advantages of good stabil ity and low risk. Besides, the patients can do functional exercises early and the shoulder joint function can be improved in great degree.

          Release date:2016-08-31 05:48 Export PDF Favorites Scan
        • Application of “door-shaft method” in limited open reduction and internal fixation with locking plate for two- and three-part fractures of the proximal humerus

          ObjectiveTo investigate the effectiveness of limited open reduction via “door-shaft method” and internal fixation with locking plate for two- and three-part fractures of the proximal humerus.MethodsThe clinical data of 64 patients with proximal humeral fractures who were admitted between January 2013 and December 2016 and met the selection criteria were retrospectively analyzed. There were 23 males and 41 females, with an average age of 68.0 years (range, 50-89 years). The injuries were caused by falling in 57 cases, traffic accident in 5 cases, and falling from height in 2 cases. The interval between injury and operation was 1-7 days (mean, 2.1 days). According to Neer classification, there were 28 cases of two-part fractures and 36 cases of three-part fractures. According to the angulation direction of the proximal humeral neck shaft angle, there were 21 cases of adduction fractures and 43 cases of abduction fractures. The fractures were treated with limited open reduction via “door-shaft method” and proximal humerus internal locking systems for internal fixation. The operation time, intraoperative blood loss, number of fluoroscopy, hospital stay, and complications were recorded. The fracture healing was reviewed by X-ray film and the healing time was recorded. The shoulder joint function was evaluated by Neer score standard.ResultsThe operation time was 45-127 minutes, with an average of 82.3 minutes. The intraoperative blood loss was 30-125 mL, with an average of 62.7 mL. Intraoperative fluoroscopy was performed 30-69 times, with an average of 37.0 times. The hospital stay was 6-23 days, with an average of 10.3 days. All incisions healed by first intention. All patients were followed up 12-37 months, with an average of 18.3 months. X-ray film re-examination showed that all fractures healed, the healing time was 12-21 weeks, with an average of 14.3 weeks. After operation, 3 cases had shoulder stiffness and 1 case had fracture malunion. At last follow-up, the Neer score of shoulder joint function was 49-97, with an average of 83.1. Among them, 38 cases were excellent, 13 cases were good, 10 cases were fair, and 3 cases were poor. The excellent and good rate was 79.7%. The excellent and good rate of patients with two-part fractures was 82.1% (23/28), and the excellent and good rate of patients with three-part fractures was 77.8% (28/36).ConclusionThe “door-shaft method” not only reduces the difficulty of the Joystick technique in the reduction of proximal humerus fractures, but also provides auxiliary stability. It is used for limited open reduction and internal fixation with locking plate to treat the two- and three-part fractures of the proximal humerus, which can achieve good effectiveness.

          Release date:2021-07-29 05:02 Export PDF Favorites Scan
        • Clinical application of anatomical locking plate in treatment of Rockwood type Ⅰ-Ⅲpatella fractures

          Objective To investigate the effectiveness of anatomical locking plate in the treatment of Rockwood type Ⅰ-Ⅲ patella fractures. Methods The clinical data of 16 patients with patella fractures who were admitted between November 2021 and January 2023 and met the selection criteria was retrospectively analyzed. There were 14 males and 2 females, with an average age of 44.5 years (range, 19-72 years). Causes of injuries included tumble in 12 cases and traffic accident in 4 cases. The fractures were rated as type Ⅰ in 2 cases, type Ⅱ in 9 cases, and type Ⅲ in 5 cases according to Rockwood classification criteria. The time from injury to operation ranged from 6 to 15 days, with an average of 9 days. After fracture reduction, an appropriate anatomical locking plate was selected for internal fixation. The operation time, intraoperative blood loss, and incision healing were recorded; the Lysholm score, B?stman patella fracture efficacy score, knee joint mobility, and pain visual analogue scale (VAS) score were used to evaluate the knee joint function and pain degree; X-ray films were used to review the fracture reduction and healing. Results The operation time was 65-100 minutes (mean, 75.3 minutes); the intraoperative blood loss was 10-35 mL (mean, 25.6 mL). All incisions healed by first intention after operation. All patients were followed up 11-26 months (mean, 19.7 months). X-ray films showed that the fractures were reduced satisfactorily, and all achieved bony healing with healing time of 3-5 months. At last follow-up, the Lysholm score was 90-95 (mean, 93.0); the B?stman patella fracture efficacy score was 27-30 (mean, 28.8), of which 12 cases were excellent and 4 were good; the VAS score was 0-1 (mean, 0.3). There was no significant difference in the range of motion of the knee joint between the healthy and affected sides [145° (140°, 150°) vs 145° (140°, 145°); Z=1.890, P=0.059]. Conclusion Choosing anatomical locking plates for Rockwood typeⅠ-Ⅲ patella fractures can achieve strong fixation with minimal surgical trauma, rapid recovery of knee joint function, and mild pain after operation.

          Release date:2024-05-13 02:25 Export PDF Favorites Scan
        • Research progress in treatment of proximal humeral fracture with fibular allograft and locking plate

          ObjectiveTo review the research progress in the treatment of proximal humeral fractures with fibular allograft and locking plate.MethodsThe literature about the treatment of proximal humeral fractures with fibular allograft and locking plate was reviewed and analyzed from the aspects such as the biomechanics, imaging prognosis, and clinical prognosis.ResultsFibular allograft and locking plate can provide effective medial support for proximal humeral fracture and increase the strength of internal fixation system. Compared with locking plate, fibular allograft combined with locking plate can maintain better humeral neck-shaft angle and the humeral head height after operation in the treatment of proximal humeral fractures, and has better shoulder mobility and shoulder joint function, and does not increase the risk of complications.ConclusionFibular allograft combined with locking plate may be a new and effective treatment for proximal humeral fractures. However, the long-term follow-up results are insufficient, the final outcome of fibula is uncertain, and the long-term potential adverse reactions caused by this treatment are still indefinite.

          Release date:2020-02-20 05:18 Export PDF Favorites Scan
        • Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation

          ObjectiveTo report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation.MethodsA new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B (n=16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score (P>0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score.ResultsThe operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B (P<0.05), but there was no significant difference in the incision length between 2 groups (t=0.672, P=0.507). All the patients were followed up 18-30 months (mean, 24 months). In group A, there were 1 case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups (P=1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B (t=2.270, P=0.031); but there was no significant difference in the Rockwood grading scores between the 2 groups at 6 months and at last follow-up (P>0.05). At last follow-up, according to the Rockwood scoring standard, the results of group A were excellent in 13 cases, good in 2 cases, poor in 1 case, the excellent and good rate was 93.75%; the results of group B were excellent in 11 cases, good in 4 cases, poor in 1 case, and the excellent and good rate was 93.75%; there was no significant difference between 2 groups (Z=–0.748, P=0.455).ConclusionThe new type of anatomic locking plate accords with the Chinese anatomical characteristics. It has the advantages of easy operative procedure, less surgical trauma, shorter operation time, less intraoperative blood loss, shorter hospitalization time, and it can achieve better results in the treatment of sternoclavicular joint fracture and dislocation.

          Release date:2018-03-07 04:35 Export PDF Favorites Scan
        • Effectiveness of tunnel osteogenesis technique in treatment of aseptic non-hypertrophic nonunion of femoral shaft

          Objective To investigate the effectiveness of tunnel osteogenesis technique combined with locking plate in the treatment of aseptic non-hypertrophic nonunion of femoral shaft. MethodsThe clinical data of 23 cases of aseptic non-hypertrophic nonunion of femoral shaft treated with tunnel osteogenesis technique combined with locking plate between January 2017 and December 2020 were retrospectively analysed. There were 17 males and 6 females with an average age of 41.4 years (range, 22-72 years). There were 22 cases of closed fracture and 1 case of open fracture. The types of internal fixation at admission included intramedullary nail in 14 cases and steel plate in 9 cases. The number of nonunion operations received in the past was 0 to 1; the duration of nonunion was 6-60 months, with an average of 20.1 months. Among them, there were 17 cases of aseptic atrophic nonunion of the femoral shaft and 6 cases of dystrophic nonunion. Twenty-two cases were fixed with 90° double plates and 1 case with lateral single plate. The operation time, theoretical blood loss, hospitalization stay, nonunion healing, and postoperative complications were recorded. Harris hip function score, Lysholm knee function score, lower extremity function scale (LEFS), and short-form 36 health survey scale (SF-36) were used at last follow-up to evaluate hip and knee functions. Visual analogue scale (VAS) score was used to evaluate the relief of pain at 1 day after operation and at last follow-up. ResultsThe average operation time was 190.4 minutes, the average theoretical blood loss was 1 458.4 mL, and the average hospitalization stay was 8.2 days. All the 23 patients were followed up 9-26 months, with an average of 18.2 months. The healing time of nonunion in 22 patients was 3-12 months, with an average of 5.6 months. There were 8 cases of limb pain, 8 cases of claudication, 6 cases of limitation of knee joint movement, and 2 cases of limitation of hip joint movement. At last follow-up, the imaging of 1 patient showed that the nonunion did not heal, accompanied by pain of the affected limb, lameness, and limitation of knee joint movement. At 1 day after operation, the VAS score of 23 patients was 6.5±1.8, the pain degree was good in 7 cases, moderate in 12 cases, and poor in 4 cases; at last follow-up, the VAS score was 0.9±1.3, the pain degree was excellent in 21 cases and good in 2 cases, which were significantly better than those at 1 day after operation (t=12.234, P<0.001; Z=–5.802, P<0.001). At last follow-up, the average Harris hip function score of 22 patients with nonunion healing was 94.8, and the good rate was 100%; Lysholm knee function score averaged 94.0, and the excellent and good rate was 90.9%; LEFS score averaged 74.6; SF-36 physical functioning score averaged 85.0 and the mental health score averaged 83.6. ConclusionTunnel osteogenesis technique combined with locking plate in the treatment of aseptic non-hypertrophic nonunion of femoral shaft has a high healing rate and fewer complications, which can effectively relieve pain and improve lower limb function and quality of patients’ life.

          Release date:2022-08-29 02:38 Export PDF Favorites Scan
        • Effectiveness comparison of a new hook-shaped anatomical locking plate and conventional anatomical locking plate in treatment of Danis-Weber type A lateral malleolus fractures

          Objective To investigate the effectiveness of a new hook-shaped anatomical locking plate in the treatment of Danis-Weber type A lateral malleolus fractures. Methods A retrospective analysis was performed on the clinical data of 45 patients with Danis-Weber type A lateral malleolus fractures who met the selection criteria between November 2020 and November 2022. According to the surgical methods, they were divided into the observation group (treated with the new hook-shaped anatomical locking plate, 23 cases) and the control group (treated with the conventional lateral malleolus anatomical locking plate, 22 cases). There was no significant difference in baseline data such as gender, age, cause of injury, Danis-Weber type of fracture, time from injury to operation, and combined ligament injury between the two groups (P>0.05). The operation time, partial weight-bearing time, return to work time, and postoperative complications were recorded and compared between the two groups. The function and pain of ankle joint were evaluated by the range of motion of ankle dorsiflexion, plantarflexion, varus, valgus, and visual analogue scale (VAS) score at 1 and 3 months after operation, and at last follow-up, and the American Orthopaedic Foot and Ankle Society (AOFAS) score at 3 months after operation and at last follow-up. Results All patients were followed up 10-18 months (mean, 15.1 months). There was no significant difference in operation time between the two groups (P>0.05); the postoperative partial weight-bearing time and return to work time of the observation group were significantly earlier than those of the control group (P<0.05). During the follow-up, there was 1 case of joint stiffness in the observation group, and 1 case of joint surface displacement, 1 case of joint stiffness, and 1 case of traumatic arthritis in the control group. There was no significant difference in the incidences of complications between the two groups (P>0.05). With the extension of time after operation, the range of motion of ankle dorsiflexion, plantarflexion, varus, valgus, and VAS score of the two groups gradually improved, and there were significant differences between different time points (P<0.05); At 1 and 3 months after operation, the above indexes in the observation group were significantly better than those in the control group (P<0.05), and there was no significant difference between the two groups at last follow-up (P>0.05). The difference of AOFAS score between the last follow-up and 3 months after operation in the observation group was significantly better than that in the control group (P<0.05). ConclusionCompared with the conventional lateral malleolus anatomical locking plate, the new hook-shaped anatomical locking plate has a more reliable fixation effect in the treatment of Danis-Weber type A lateral malleolus fracture, which is conducive to early functional exercise of the ankle joint, so that patients can bear weight earlier and return to work earlier, and the operation time is not significantly prolonged, and the effectiveness is satisfactory.

          Release date:2024-05-13 02:25 Export PDF Favorites Scan
        • EFFECTIVENESS OF VERY LOW PROFILE/VARIABLE ANGLE LOCKING PLATE INTERNAL FIXATION IN TREATMENT OF POSTERIOR Pilon FRACTURES EXTENDING TO MEDIAL MALLEOLUS BY POSTEROMEDIAL APPROACH

          ObjectiveTo evaluate the effectiveness of very low profile/variable angle locking plate (VLP) internal fixation for posterior Pilon fractures extending to the medial malleolus by posteromedial approach. MethodsA retrospective analysis was made on the clinical data from 13 patients with posterior Pilon fractures extending to the medial malleolus between December 2011 and August 2012. There were 4 males and 9 females with an average age of 48.9 years (range, 23-68 years). Fractures were caused by falling in 9 cases and by traffic accident in 4 cases. The locations were the left ankle in 6 cases and the right ankle in 7 cases. According to the Orthopedic Trauma Association (OTA) classification, 6 cases were rated as type 43B1, 4 cases as type 43B2, and 3 cases as type 43B3. Twelve cases had fibular fractures, including 11 cases of Denis-Weber type B, 1 case of Denis-Weber type C. The interval of injury and operation was 7-14 days (mean, 11.4 days). Open reduction was performed and VLP internal fixation was used for posterior malleolar fracture by posteromedial approach. ResultsPrimary healing of incision was obtained in all patients. Tibial nerve palsy was observed in 2 cases, and was cured after oral administration of mecobalamin. Twelve cases were followed up 12-18 months (mean, 14.5 months). According to the Burwell-Charnley's radiological evaluation system, 11 cases achieved anatomical reduction, 1 case achieved fair reduction. The fracture union time was 3-6 months (mean, 3.7 months). No loosening or breakage of internal fixation occurred during follow-up. According to the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, the results were excellent in 7 cases, good in 4, and fair in 1; the excellent and good rate was 91.7%. ConclusionVLP internal fixation for posterior Pilon fractures extending to the medial malleolus by posteromedial approach can achieve good short-term effectiveness. The high quality of reduction is acquired under direct vision with low rate of soft tissue complications.

          Release date: Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜