• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "wire" 53 results
        • CT-guided Hook-wire versus microcoil localization in the pulmonary nodules surgery: A systematic review and meta-analysis

          ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI ?3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.

          Release date:2023-06-13 11:24 Export PDF Favorites Scan
        • Clinical analysis of CT-guided preoperative Hookwire localization of pulmonary nodules in 102 patients

          ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.

          Release date:2022-01-21 01:31 Export PDF Favorites Scan
        • Application of 3D reconstruction and Hookwire to localize pulmonary nodules in thoracoscopic pulmonary segmentectomy

          ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .

          Release date:2020-07-30 02:16 Export PDF Favorites Scan
        • A case report of transcatheter aortic valve replacement with descending aorta severe distortion

          An 89 years old male patient was admitted to the First Medical Center of Chinese PLA General Hospital due to chest tightness and shortness of breath for half a month. Severe aortic valve stenosis was found in post admission assessment. We proposed to perform transcatheter aortic valve replacement surgery. Preoperative evaluation showed severe distortion of the descending aorta. We used the double guide wire technique and a 14F long sheath to assist the stepwise balloon expansion, and successfully completed the valve implantation. For patients with severe tortuous aorta, how to successfully complete transcatheter aortic valve replacement, this case may provide some reference.

          Release date:2020-05-26 02:34 Export PDF Favorites Scan
        • Application of novel wire system for echo-guiding percutaneous atrial septal defect closure

          ObjectiveTo evaluate the efficacy and safety of a novel wire for echo-guiding percutaneous atrial septal defect (ASD) closure.MethodsTwenty sheep were randomly divided into two groups, an experimental group and a control group (n=10 in each group). In both groups, an animal model of ASD was established by transthoracic balloon dilatation, and percutaneous closure of atrial septal defect was finished only by echography guiding. The total procedure time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into right atrium, frequency of arrhythmias and rate of complications were compared between the two groups.ResultsASD model was uneventfully established in all animals. ASD devices were successfully implanted in all sheep. Compared with the control group, the experimental group had significantly less mean procedure time and mean passing time, lower frequency of guide wire dropping into right atrium and frequency of atrial and ventricular premature contractions, respectively (15.36±4.86 min vs. 25.82±7.85 min, 2.69±0.82 min vs. 5.58±3.34 min, 0% vs. 40.0%, 4.41±2.61 vs. 9.60±3.68, 0.75±0.36 vs. 1.34±0.68; all P<0.05) . Two groups did not have serious complications within postoperative one week.ConclusionThe novel wire system is not only safe and effective in the treatment of ASD occlusion, but also easy to operate.

          Release date:2019-01-23 02:58 Export PDF Favorites Scan
        • The application of silicon nanowires field-effect transistor biosensor in medicine

          Ultra-sensitive and quantitative analysis of proteins, nucleic acid, virus and other biochemical species are critical technologies for effective dianosis of disease, as well as medical studies. Silicon nanowires field-effect transistor (SiNWs-FET) biosensor is one of the most promising powerful platforms for label-free, real-time, ultra-sensitive detection of analyte. Here, the working principle of SiNWs-FET biosensor and the applications of SiNWs-FET biosensors in medicine were introduced. Moreover, the methods for enhancing the sensitivity of SiNWs-FET biosensor were discussed. Lastly, the prospecting of SiNWs-FET biosensor was presented.

          Release date:2017-10-23 02:15 Export PDF Favorites Scan
        • MODIFIED INTRAMEDULLARY FIXATION WITH TWO Kirschner WIRES FOR EXTRA-ARTICULAR FRACTURE OF PROXIMAL PHALANGEAL BASE

          ObjectiveTo evaluate the effectiveness of the modified intramedullary fixation with two Kirschner wires for extra-articular fracture of the proximal phalangeal base. MethodsBetween June 2012 and November 2015, 18 cases (18 fingers) of fresh extra-articular fracture of the proximal phalangeal base were treated, including 16 males and 2 females with an average age of 31 years (range, 21-57 years). The causes included strike injury in 10 cases, fall injury in 4 cases, mechanical injury in 1 case, twist injury in 1 case, crush injury in 1 case, and cutting injury in 1 case. The injured fingers were little finger in 16 cases, ring finger in 1 case, and index finger in 1 case. Of the 18 cases, 17 had closed fractures and 1 had open fracture. X-ray film showed transverse fracture in 14 cases and transverse-oblique fracture in 4 cases. The time between injury and operation was 3 hours to 4 days (mean, 2 days). After anatomical reduction, two Kirschner wires were used for intramedullary fixation. Functional exercises were done at 2 days after operation. The Kirschner wires were removed at 4 weeks after operation. ResultsAll the wounds healed by first intention. There were no deformation, loosening or breakage of Kirschner wires, and pin tract infection. Postoperative X-ray films showed anatomical reduction of fracture in all cases; no re-displacement happened, and clinical healing was obtained at 4 weeks; bony union was obtained at 8 weeks. All patients were followed up 6-12 months with an average of 8 months. There was no pain in the metacarpophalangeal joint; the range of motion was (88.1±2.3)° at 3 months after operation, showing no significant difference when compared with normal side [(88.8±2.6)°] (t=1.73, P=0.10). The finger flexion and extension were normal; according to the criteria of total active motion of finger, the results were excellent in all cases. ConclusionThe technique of modified intramedullary fixation with two Kirschner wires for extra-articular fractures of the proximal phalangeal base has the merits of convenient operation, little injury, reliable fixation, and excellent effectiveness. This technique is conducive to the recovery of hand function due to the early functional exercises.

          Release date: Export PDF Favorites Scan
        • Interpretation of 2021 China Chest Pain Center Quality Control Report

          The Medical Administration and Hospital Administration of the National Health Commission released the "2021 China Chest Pain Center Quality Control Report" in January 2022. This report analyzes the construction ratio of chest pain centers in the second-level and above medical institutions nationwide in 2021 and the construction of standard and basic chest pain centers, mainly from the way of coming to the hospital, symptom onset to first medical contact time, door to wire time, reperfusion therapy ratio, in-hospital mortality, proportion of discharges with medication recommended by the guidelines and average length and cost of hospital stay of ST-segment elevation myocardial infarction patients to comprehensively describe the current status of the construction of the national chest pain centers. This article interprets the report in detail by reviewing relevant literature.

          Release date:2022-11-22 02:01 Export PDF Favorites Scan
        • Effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in treatment of inferior patellar pole avulsion fractures

          ObjectiveTo explore the method and effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures.MethodsBetweern January 2015 and January 2019, 22 patients with inferior patellar pole avulsion fractures were admitted and treated. There were 12 males and 10 females. The age ranged from 20 to 69 years, with an average age of 39.4 years. The causes of injury included 9 cases of traffic accident and 13 cases of falling. All of them were unilateral closed injury of knee joint, including 7 cases of skin contusion around patella. Preoperative range of motion of the affected knee was (20.82±7.16)° (range, 10°-35°). The time from injury to operation ranged from 3 to 12 days, with an average of 5.9 days. During the operation, the inferior patellar avulsion fracture was reduced with forceps; the patella was circumferentially ligated through the distal bone surface of the fracture with 0.8 mm diameter steel wire; then 3 longitudinal bone tunnels were made in the upper patella, respectively. The 0.8 mm diameter steel wire passed through the bone tunnel, and the longitudinal ring was attached to the ring to fix the upper and inferior patellar fracture. Tighten the transverse and longitudinal rings with No.2 tendon suture line, then longitudinally ringed and sutured to strengthen the patella. The knee range of motion, fracture healing time, and complications were recorded. The functional recovery of the knee joint was evaluated by B?stman score.ResultsAll incisions healed by first intention, and no incision related complications occurred. All the 22 patients were followed up 13 months to 5 years with an average of 26.7 months. The fracture healing time was 9-12 weeks (mean, 10.9 weeks). At last follow-up, the knee range of motion was (129.77±2.35)° (range, 126°-135°), showing significant difference when compared with preoperative one (t=?67.022, P=0.000). The B?stman score ranged from 31 to 36, with an average of 34.3. No reduction loss, fracture of steel wire, failure of internal fixation, and other complications occurred during follow-up.ConclusionMultidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures has the advantages of reliable fixation, early functional recovery, and fewer complications, so the effectiveness is satisfactory.

          Release date:2021-02-24 05:33 Export PDF Favorites Scan
        • Effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in treatment of Cho type ⅡC distal clavicle fractures

          Objective To evaluate the effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures. Methods The data of 17 patients with Cho type ⅡC distal clavicular fractures, who were treated with Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor between June 2019 and June 2021, was retrospectively analyzed. There were 11 males and 6 females with an average age of 38.7 years (range, 19-72 years). The fractures were caused by falling in 12 cases and traffic accident in 5 cases. All patients had fresh closed fractures. The interval from injury to operation was 1-5 days (mean, 2.6 days). The preoperative injury severity score (ISS) was 6-27 (mean, 10.2). The operation time, intraoperative blood loss, hospital stay, fracture healing, and postoperative complications were analyzed. The shoulder joint function was evaluated by disabilities of the arm, shoulder, and hand (DASH) score and Constant score at last follow-up. Results All operations were completed successfully. The operation time was 20-50 minutes (mean, 31.6 minutes). The intraoperative blood loss was 30-100 mL (mean, 50.6 mL). The hospital stay was 4-9 days (mean, 5.3 days). All incisions healed by first intention. All patients were followed up 12-16 months (mean, 13 months). All clavicle fractures healed, and the healing time was 8-15 weeks (mean, 11 weeks). No complications such as fracture displacement or nonunion caused by internal fixation failure occurred. During the follow-up, skin irritation caused by the Kirschner wire withdrawal occurred in 3 cases. The Kirschner wires were removed after fracture healing in 17 patients. At last follow-up, the Constant score of shoulder joint was 90-100 (mean, 98.2). The DASH score was 0-10 (mean, 1.5). ConclusionKirschner wire fixation combined with coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures has less postoperative complications and slight complications. It is convenient to remove the internal fixator. The Kirschner wire does not fix the distal clavicle fracture through the acromion, which has little effect on shoulder joint function and can obtain good effectiveness.

          Release date:2023-12-12 05:05 Export PDF Favorites Scan
        6 pages Previous 1 2 3 ... 6 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜