ObjectiveTo evaluate the early and mid-term safety of transcatheter aortic valve replacement via transfemoral (TF), transapical (TAp) and transsubclavian (TSc) approaches by meta-analysis.MethodsWe systematically searched the clinical comparative trials published from inception to June 2019 from PubMed, Web of Science, EMbase and The Cochrane Library, to evaluate the safety of transcatheter aortic valve replacement through TF, TAp or TSc approaches. The information of all-cause mortality at 30 days, 1 year, 2 years and the incidence of common complications at 30 days after operation (including pacemaker-dependent block, major vascular complications, severe bleeding events, acute renal injury and stroke) were exacted, and a meta-analysis was conducted by RevMan 5.3 software.ResultsThis study included 11 literatures, with a total of 7 833 patients, among whom 5 348 patients were treated by TF TAVR, 1 796 patients by TAp TAVR and 689 patients by TSc TAVR. The results of the meta-analysis were as follows: (1) at 30 days after operation, the mortality of TF and TSc approaches were lower than that of the TAp approach (TF vs. TAp: OR=0.57, 95%CI 0.39-0.84, P=0.004; TSc vs. TAp: OR=4.12, 95%CI 1.93-8.79, P=0.000 3). There was no statistical difference between the TF and TSc approaches (TF vs. TSc: OR=0.98, 95%CI 0.38-2.51, P=0.97); at 1 year, there was no statistical difference in mortality among the three approaches (P>0.05); at 2 years, there was no statistical difference between TSc and TF or TAp approaches (TF vs. TSc: OR=1.21, 95%CI 0.95-1.54, P=0.13; TSc vs. TAp: OR=1.02, 95%CI 0.76-1.36, P=0.91). (2) The incidence of acute kidney injury after TF approach was lower than that of the TAp approach (OR=0.30, 95%CI 0.22-0.41, P<0.000 01). (3) There was no statistical difference in major vascular complications between TSc and TF or TAp approaches (TF vs. TSc: OR=0.75, 95%CI 0.38-1.49, P=0.41; TSc vs. TAp: OR=1.37, 95%CI 0.56-3.32, P=0.49). (4) There was no statistical difference in severe bleeding events between TF and TSc (OR=0.97, 95%CI 0.53-1.76, P=0.92). (5) There was no statistical difference in the incidence of postoperative stroke, pacemaker dependent block among the three approaches (P>0.05).ConclusionTAp and TSc approaches are safe and effective. They are not only an alternative to TF approach, but also the first choice in some patients with poor condition of iliofemoral artery.
ObjectiveTo research the procedure for creating an animal model of mitral regurgitation by implanting a device through the apical artificial chordae tendineae, and to assess the stability and dependability of the device. MethodsTwelve large white swines were employed in the experiments. Through a tiny hole in the apex of the heart, the artificial chordae tendineae of the mitral valve was inserted under the guidance of transcardiac ultrasonography. Before, immediately after, and one and three months after surgery, cardiac ultrasonography signs were noted. Results All models were successfully established. During the operation and the follow-up, no swines died. Immediately after surgery, the mitral valve experienced moderate regurgitation. Compared with preoperation, there was a variable increase in the amount of regurgitation and the values of heart diameters at a 3-month follow-up (P<0.05). ConclusionIn off-pump, the technique of pulling the mitral valve leaflets with chordae tendineae implanted transapically under ultrasound guidance can stably and consistently create an animal model of mitral regurgitation.
Objective To investigate the feasibility and early efficacy of transapical transcatheter aortic valve replacement (TAVR) combined with transcatheter mitral valve edge-to-edge repair (TEER) in patients with high-risk aortic valve lesions combined with severe mitral regurgitation. Methods The clinical data of patients who underwent "one-stop" transapical TAVR+TEER in our hospital from August 2022 to October 2023 were retrospectively analyzed. Results Five patients were collected, including 3 males and 2 females with a mean age of 66.6±1.8 years. Four patients had aortic valve insufficiency combined with mitral regurgitation and one had aortic valve stenosis and insufficiency combined with mitral regurgitation. All patients successfully completed transapical TAVR+TEER, and the immediate postoperative echocardiographic results revealed that none of them had more than mild perivalvular leakage and mitral regurgitation, and the prosthetic valves were in good position and function. At 1 week postoperatively, echocardiographic results showed 5 patients with no displacement of the prosthetic valve, detachment of the mitral clip, or damage to the leaflets. At 1 month postoperatively, cardiac function was improved to varying degrees in 4 patients, and 1 patient died of multiorgan failure. At 2 months postoperatively, 1 patient died of cerebrovascular accident, and at 3 months postoperatively the echocardiographic results of the remaining 3 patients revealed that there was no more than mild perivalvular leakage or mitral regurgitation, and the patients' postoperative cardiac function and daily life ability were significantly improved. Conclusion In high-risk aortic valve lesions combined with severe mitral regurgitation, "one-stop" transapical TAVR+TEER is feasible with favorable early efficacy and safety.
ObjectiveTo assess the early outcome of transapical transcatheter aortic valve replacement (TAVR) for patients with aortic insufficiency. MethodsThe patients with aortic valvular disease who underwent transapical TAVR from October 2020 to October 2022 in the Department of Cardiac and Vascular Surgery, the First Affiliated Hospital of Anhui Medical University were enrolled in the current retrospective study. The patients with aortic stenosis were assembled in a group A, and the patients with aortic insufficiency were assembled in a group B. The improvements of heart function and complications were assessed for the two groups. ResultsA total of 56 patients were enrolled, including 32 males and 24 females with an average age of 73.34±5.10 years. There were 31 patients in the group A and 25 patients in the group B. There was no statistical difference between the two groups in the age, gender, height, weight, hypertension, coronary artery disease, peripheral vascular disease, chronic obstructive pulmonary disease, renal disorder or classification of heart function (P>0.05). Also, there was still no statistical difference in the rate of permanent peacemaker implants, emergent open surgery, valve re-implants, or perivalvular leakage (P>0.05). After TAVR, the left ventricular diastolic diameter, left ventricular ejection fraction, complicated moderated mitral and tricuspid regurgitation were significantly improved in both groups compared with preoperative findings (P<0.05); however, there was no statistical difference in these parameters between groups (P>0.05). ConclusionInterventional valve (J-Valve) in the treatment of patients with aortic insufficiency through transapical TAVR significantly improves cardiac function and reduces functional valve regurgitation.
ObjectiveTo investigate the reliability and safety of the technique of percutaneous left ventricular transapical access guided by cardiac three dimensional CT angiography (3D-CTA) combined with echocardiography applied in structural heart defects.MethodsThe clinical data of 9 patients (7 males and 2 females with a median age of 50 years ranging from 43 to 64 years) with paravalvular leaks closed by percutaneous left ventricular transapical access in West China Hospital, from April 2015 to August 2018, were retrospectively analyzed. We applied preoperative cardiac 3D-CTA to define the puncture site and trace, which was established by combining with real-time guidance of transesophageal echocardiography (TEE/3D-TEE), and an occluder was deployed at the apical access point for hemostasis with real-time guidance of transthoracic echocardiography (TTE).ResultsThe puncture needles were successfully introduced into the left ventricular cavity at one time in all patients without injury of lung tissue, coronary artery or papillary muscle. There was no occluder displacement or apex bleeding. One patient developed pleural effusion caused by intercostal artery injury.ConclusionThat cardiac 3D-CTA is used to define puncture sites and trace with advantages of simplicity and repeatability. A safe access and secure exit of left ventricle can be achieved by combining with real-time guidance of echocardiography. There are acceptable technology-related complications.
ObjectiveTo compare the early clinical efficacy and safety of transapical transcatheter aortic valve implantation (TA-TAVI) with surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis (AS). MethodsA retrospective study was conducted on patients with severe AS admitted to the Department of Cardiovascular Surgery, The First Affiliated Hospital of University of Science and Technology of China from January 2020 to March 2024. According to the surgical method, patients were divided into a SAVR group and a TA-TAVI group, and the clinical data of the two groups were compared. ResultsA total of 71 patients were included, with 45 in the SAVR group, including 33 males and 12 females, aged 16-75 (60.89±10.88) years; 26 in the TA-TAVI group, including 15 males and 11 females, aged 61-83 (72.85±5.53) years. The results showed that postoperative aortic valve transvalvular flow velocity [(2.31±0.38) m/s vs. (2.60±0.50) m/s, P=0.019] and transvalvular pressure gradient [(21.09±6.03) mm Hg vs. (28.20±10.79) mm Hg, P=0.001] in the TA-TAVI group were lower than those in the SAVR group. In terms of left ventricular end-diastolic diameter, both preoperative [(56.73±7.74) mm vs. (52.36±7.00) mm, P=0.017] and postoperative [(52.61±7.18) mm vs. (48.04±4.78) mm, P=0.010] values in the TA-TAVI group were larger than those in the SAVR group. In terms of left ventricular ejection fraction, the preoperative value in the TA-TAVI group was lower than that in the SAVR group (58.00%±13.84% vs. 64.87%±7.63%, P=0.026), but there was no statistical difference between the two groups after surgery (P=0.670). The operation time and drainage volume on the first day after surgery in the TA-TAVI group were shorter or lower than those in the SAVR group (P<0.05). There was no statistical difference between the two groups in the postoperative hospital stay, ICU stay, or postoperative mechanical ventilation time (P>0.05). In addition, no serious complications occurred in patients after SAVR, while perivalvular leakage (2 patients), third-degree atrioventricular block (1 patient), and death (3 patients) occurred in the TA-TAVI group. ConclusionFor elderly patients with severe AS and poor cardiac function, TA-TAVI technology has minimal surgical trauma, high safety and effectiveness, and is a safe and effective treatment option besides traditional surgical operations.
According to the needs of CT image evaluation for transapical transcatheter aortic valve replacement (TAVR), 20 clinical questions were proposed by the Delphi method, 15 questions were initially determined, and 12 clinical questions were summarized and determined by domestic experts. PubMed, Web of Science, Wanfang, and CNKI databases were searched by computer to collect the relevant literature from inception to November 2022, and finally 53 studies were included. Based on evidence-based study and evaluation experience, 3 meetings were held to give recommendations for preoperative CT data acquisition method, preoperative imaging evaluation of aortic root, imaging evaluation of transapical approach, preoperative auxiliary guidance of TAVR by CT images combined with 3D printing, and postoperative imaging evaluation of transapical TAVR, hoping to promote the standardized and successful development of transapical TAVR in China.
Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. The localization and anchor of many transcatheter heart valves available in the clinic today are dependent on the calcific aortic valve leaflet of patients. We reported here a successful case of transapical aortic valve implantation with Ken-Valve heart valve in an 82-year-old male patient with pure severe aortic regurgitation without native valve calcium. Postoperative follow-up (3 months after the surgery) showed that the cardiac function significantly improved. The echocardiography indicated that the Ken-Valve prosthesis worked well without perivalvular regurgitation. The short-term clinical effect was satisfactory. The Ken-Valve with three position anchors is proved to be suitable for the treatment of pure aortic regurgitation.
ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.
We reported a 26-year-old male who was diagnosed with apical hypertrophic cardiomyopathy with left ventricular aneurysm. The location of the hypertrophic myocardium and the extent of resection were accurately assessed preoperatively using 3D modeling and printing technology. Myectomy was performed via transapical approach, and the intraoperative exploration was consistent with the description of the preoperative 3D modeling. The patient underwent the surgery successfully without any complications during the hospitalization, and the cardiopulmonary bypass time was 117 min, the aortic cross-clamping time was 57 min, and the hospital stay time was 7 d. The postoperative echocardiography demonstrated left ventricular cavity flow patency. This case provides a reference for the management of patients with apical hypertrophic cardiomyopathy.