• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "plate" 398 results
        • TREATMENT OF INTRA-ARTICULAR CALCANEAL FRACTURE BY BONE GRAFTING AND PLASTIC TI-ALLOY PLATE INTERNAL FIXATION

          To investigate the therapeutic effect of open reduction, bone grafting, and internal fixation with plastic ti-alloy plate on intra-articular calcaneal fracture. Methods From January 2005 to December 2007, 32 patients (37 feet) with intra-articular calcaneal fracture underwent open reduction, bone grafting of autogeneic il ium (30-80 g) and internal fixation of plastic ti-alloy plate. There were 21 males and 11 females aged 18-56 years old (average 42.1 years old). There were 5 cases of bilateral calcaneal fracture and 27 cases of unilateral calcaneal fracture, including 2 cases of open fracture and 30 cases of close fracture. According to Sanders classification system, there were 11 cases of type II, 18 cases of type III and 8 cases of type IV. Preoperatively, Bouml;hler angle was (— 9.6 ± 4.2)° and Gissane angle was (101.4 ± 10.6)°. Nine feet underwent emergency operation and 28 feet received operation 5-7 days after injury. Results The wounds of 34 feet healed by first intention. The wound margin of 3 feet was gray with a small amount of colorless exudates, and healed after dressing change. All patients were followed for 12-24 months (average 16 months). X-ray films displayed that the fracture all healed within 3-4 months after operation. At 6 months after operation, the Bouml;hler angle and the Gissane angle was (28.5 ± 6.1)° and (128.9 ± 4.8)°, respectively, indicating there were significant differences when compared with before operation (P lt; 0.05). According to Maryland foot score system, 15 cases were graded as excellent, 18 cases were good, 4 cases were poor, and the excellent and good rate was 89.19%. Conclusion Open reduction, bone grafting, and internal fixation with plastic ti-alloy plate is an effective method to treat intra-articular calcaneal fracture. Choosing right operational timing, performing subarticular surface grafting when necessary and using appropriate plastic ti-alloy plate internal fixation can minimize the incidence of postoperative compl ications

          Release date:2016-09-01 09:07 Export PDF Favorites Scan
        • Effectiveness of open reduction and locking compression hook plate in treatment of isolated humeral greater tuberosity fractures

          Objective To observe the effectiveness of locking compression hook plate in treatment of humeral greater tuberosity fractures. Methods Between March 2014 and September 2017, 16 patients with isolated humeral greater tuberosity fractures were terated with open reduction and internal fixation with locking compression hook plates. There were 11 males and 5 females, with an average age of 38.4 years (range, 22-67 years). The cause of injury was falling injury in 13 cases and sport injury in 3 cases. All patients were closed fractures. Of all patients, 14 patients accompanied with shoulder joint dislocations. CT scan showed the average displacement of fragment was 12.6 mm (range, 8-21 mm) after reduction. All patients began passive functional exercise at 3 days after operation. Results Primary healing of the incisons achieved in all patients, without complications such as infection and nerve injury. All patients were followed up 12-20 months (mean, 15.3 months). At 3 months after operation, X-ray film showed that all fractures achieved bone union, all of which met the imaging anatomical reduction standard. According to the Neer scoring criteria, 11 cases were excellent and 5 cases were good at last follow-up. One patint presented slight pain of shoulder joint and mild activity limitation, which relieved after 1 year. Conclusion The method of open reduction and locking compression hook plate internal fixation for isolated humeral greater tuberosity fractures has advantages, such as less intraoperative hemorrhage, mild postoperative pain, firm fixation, and allowing patients to perform functional exercise earlier, which is conducive to shoulder functional recovery and obtain satisfactory effectiveness.

          Release date:2019-05-06 04:46 Export PDF Favorites Scan
        • BIOMECHANICAL EFFECTS OF ILIAC SCREW PLATES ON STABILITY OF LUMBO-ILIAC FIXATION CONSTRUCT

          Objective To evaluate the biomechanical effect of a self-made iliac screw plate on the stability of lumbo-iliac fixation construct before and after fatigue loading. Methods Twelve fresh lumbo-pelvic specimens from donated adult cadavers with formalin embalm were used in the study. According to whether use the iliac screw plate or not, the specimens were randomly assigned into group A (with iliac screw plate, n=6) and group B (without iliac screw plate, n=6). The bone mineral density (BMD) of L1-4 was measured using dual-energy radiograph absorptiometry. The pedicle screw and iliac screw fixation were given at L3-5, and bilateral facetectomy and diskectomy at L5, S1 level were performed to prepare the model of the intervertebral destabilization. The biomechanical testing was conducted on a material testing machine under 0-600 N compression and — 7-7 N · m torsion loading modes for the initial compressive stiffness and torsional stiffness evaluation. And then 20 000 cyclic compressive loading of 40-400 N was given to the specimen, the stiffness evaluation was repeated. Then the maximum pull-out strength of screws at every level was measured and compared. Gross observation and radiological observation were performed during experiment. Results The BMD values of groups A and B were (1.15 ± 0.13) g/cm2 and (1.12 ± 0.11) g/ cm2 respectively, showing no significant difference between 2 groups (t=0.428, P=0.678). All pedicle screws and iliac screws were inserted in good position; no loosening or breaking of screw was observed during loading. After fatigue loading, the incidence of halo ring around the iliac screws of groups A and B was 16.7% (1/6) and 50.0% (3/6), respectively. The compressive stiffness and torsional stiffness after fatigue loading were significantly lower than those in initial state in groups A and B (P lt; 0.05); there was no significant difference in compressive stiffness and torsional stiffness between groups A and B before fatigue loading (P gt; 0.05). However, group A had higher compressive stiffness than group B (t=2.664, P=0.024) after fatigue loading, and there was no significant difference in torsional stiffness between 2 groups (t=0.410, P=0.690). No significant difference was found in screw pull-out strength of pedicle screws at L3, L4, and L5 levels between groups A and B (P gt; 0.05); however, the pull-out strength of the iliac screws in group A was significantly higher than that in group B (t=3.398, P=0.007). In groups A and B, the pull-out strength of L3 screw was significantly lower than that of L4 and L5 screws (P lt; 0.05). In group A, pull-out strength of the iliac screws was significantly higher than that of L3, L4, and L5 screws (P lt; 0.05); in group B, the pull-out strength of iliac screws was significantly lower than that of L4 and L5 screws (P lt; 0.05). Conclusion In the lumbo-iliac reconstruction, the use of iliac screw plate could resist iliac screw loosening, therefore, it has the potential to increase the stability of lumbo-iliac fixation construct.

          Release date:2016-08-31 04:07 Export PDF Favorites Scan
        • LOCKING COMPRESSION PLATE FIXATION FOR PERIPROSTHETIC FEMORAL FRACTURE

          Objective To introduce a method for fixation in periprosthetic fracture with locking compression plate (LCP). Methods Duringthe surgery, a long 12-hole LCP was placed to the lateral side of the femur. Six holes of the plate were placed proximal to the main fracture line to make sure that there could be enough cortex units for rigid fixation of proximal fragments. Locking screws used except for the most proximal hole where a 4.5 mm screw was used instead. Results The patient was pain free at the fracture site one week after the surgery,and was able to walk with a cane 3 months after the surgery. Bone union was evident radiographically 3 months after the surgery. There was no loose signs around the stem. Six months after the surgery, the patient recovered full function without pain. Conclusion In our experience from this case, LCP in treating periprosthetic fracture was easy and less time consuming, more over, extensive periosteal stripping could be avoided. LCP is a good choice in treating some periprosthetic fractures.

          Release date: Export PDF Favorites Scan
        • Preparation and application of a PDGFRβ-targeted near-infrared fluorescent probe for molecular optical imaging of lung cancer

          ObjectiveTo prepare platelet-derived growth factor receptor β (PDGFRβ)-targeted near-infrared molecular probe and evaluate its potential in optical molecular imaging of lung cancer.MethodsPDGFRβ-specific affibody Z-tri was recombinantly expressed in Escherichia coli (E. coli) and purified using affinity chromatography. In vitro cell-binding of Z-tri was analyzed by flow cytometry. Cellular distribution of Z-tri in tumor grafts was determined by protein-tracing. The molecular probe CF750-Z-tri was prepared by conjugating near-infrared fluorescent dye CF750 to Z-tri. The optical images of xenografts of lung cancer were obtained by using CF750-Z-tri combined with optical imaging system.ResultsPDGFRβ-specific affibody Z-tri was highly expressed in E. coli and purified to homogeneity. Z-tri could bind PDGFRβ-positive cells but not PDGFRβ-negative cells cultured in vitro. In the tumor xenografts of human lung cancer, intravenously injected Z-tri was predominantly distributed on cells overexpressing PDGFRβ. The near infrared fluorescent dye CF750 was efficiently conjugated to Z-tri. Optical images with high contrast of lung cancer xenografts were produced by using the near-infrared fluorescent probe CF750-Z-tri combined with optical imaging system.ConclusionThe near-infrared fluorescent probe CF750-Z-tri can be used for optical imaging of human lung cancer, which takes great potential in optical imaging-guided surgery of lung cancer.

          Release date:2021-07-28 10:02 Export PDF Favorites Scan
        • COMPARISON OF PLATE AND KIRSCHNER WIRE FIXATION IN TREATMENT OF CLAVICULAR NONUNION

          Objective To compare the results of plate and Kirschner wire fixation in treatment of nonunion of clavicular fracture. Methods From September 1991 to January 2002, 19 patients (9 with plate and 10 with Kirschner wire) were treated. The results were evaluated by reduction, bone union time, recovery of joint function, pain, and correction of deformation. Results The follow-up time was 6-23 months with an average of 11 months. Bone union -occurred after a mean time of 11 weeks. In plate group, 7 patients gained excellent results, 1 good and1 fair. In Kirschner wire group, 3 patients gained excellent results, 3 good, 3 fair and 1 poor. The result of plate is significantly better than that of Kirschner wire fixation(Plt;0.05). Conclusion Plate fixation is a good simple method for treatment of nonunion of clavicular fracture.

          Release date: Export PDF Favorites Scan
        • FAILURE AND PREVENTION OF RECONSTRUCTION IN ANTERIOR STABILITY OF SPINE BY DUAL BLADE PLATE

          Abstract Dual-blade plate is widely used in reconstruction of anterior stability of spine. Two hundred and ninety-eight cases were followed up since 1984. Among them, 181 cases were fractureof thoracolumbar spine; 63 cases were tuberculosis of thoracolumbar spine; 43 cases were tumor of thoracolumbar spine; 5 cases were spondylisthesis of lumbar spine; 2 cases were ankylosing spondylitis accompanied with gibbosity; 2 cases were adolescent vertebral epiphysis; I case was hemivertebra; I case was dysplasia of the first lumbar vertebra acompanied with gibbosity. Most cases were successful following operation, but in some cases, the results were unsuccessful, mainly due to the position of the dualblade plate in the vertebral body was not satisfactory. The mistakes most commonly occurred were one or two blades, or a part of the blade going into the intervertebral space, and less commonly seen was deviation of the dual -blade plate from itscorrect orientation or a little side-bent of the blade. Split of the vertebra and fall off of the dual-blade plate were happened in few cases. The causeswere analyzed and ways of prevention were provided in this article.

          Release date:2016-09-01 11:11 Export PDF Favorites Scan
        • DESIGN OF NONINVASIVE STEEL MINIPLATE FOR TENODESIS AND ITS CLINICAL APPLICATION

          To fix the ligaments, tendons or other transplantation materials by passing through bone channels was commonly used and a relialde method in the reconstruction of joint stability. Usually an additional incision was necessary on the side of the outlet of the bone channel, that the screws, plates or U-shaped staple could be applied. An instrument was designed that the steel miniplate could be fixed to the bone by noninvasive method. This technique was applied in 20 cases in which anterior cruciate ligament in 14, posterior cruciate ligament in 4, and collateral ligaments in 2 with carbon fibers. The result was successful in all patients. It was shown that it gave simple manipulation, reliable fixation and no need to have an additional incision, and it could lessen patients’ suffering and lead to satisfactory clinical result.

          Release date:2016-09-01 11:08 Export PDF Favorites Scan
        • Self-made dentation hook plate associated with hot-air balloon technique on treatment of Mutch Ⅰ or Ⅱ type isolated greater tuberosity fractures of humerus

          ObjectiveTo observe effectivness and safeness of self-made dentation hook plate associated with hot-air balloon technique in treating Mutch Ⅰ or Ⅱ type isolated greater tuberosity fractures of humerus.MethodsBetween January 2016 and December 2018, 15 patients with Mutch Ⅰ or Ⅱ type greater tuberosity fractures were treated with self-made dentation hook plate associated with hot-air balloon technique. There were 9 males and 6 females with an average age of 45.1 years (range, 29-62 years). The injury causes included falling injury in 9 patients and traffic accident injury in 6 patients. According to Mutch classification, 4 cases were MutchⅠ type and 11 cases were Mutch Ⅱ type. There were 7 cases with anterior dislocation of shoulder. The time from injury to operation was 2-10 days (mean, 4.5 days).ResultsAll 15 patients were followed up 8-16 months, with an average of 13.5 months. There was no infection of incision, loss of reduction of fracture block, delayed union or nonunion. The average time of fracture union was 6.5 months (range, 4-8 months). One patient had axillary paralysis at 1 day after operation, and was treated with nutritional nerve therapy, the symptoms disappeared after 2.5 months. Three patients had slight subacromial impingement. After fracture healing, the hook plate was taken out in advance, and the pain and abnormal noise disappeared during shoulder abduction. At last follow-up, Costant-Murley score used to evaluate shoulder joint function was 88-100, with an average of 96.8; 8 cases were excellent, 7 cases were good, and the excellent and good rate was 100%. The internal fixator was removed after 8-16 months after the secondary operation with no re-fracture occurred.ConclusionThe self-made dentation hook plate associated with hot-air balloon technique is a safe and reliable method for the treatment of Mutch Ⅰ or Ⅱ type isolated greater tuberosity fracture of humerus.

          Release date:2020-09-28 02:45 Export PDF Favorites Scan
        • Effects of autologous platelet-rich gel on the treatment of refractory diabetic foot ulcer

          Objective To investigate the effects of autologous platelet-rich gel (APG) combined with intelligent trauma negative-pressure comprehensive therapeutic instrument on patients with refractory diabetic foot ulcer (DFU). Methods A total of 80 patients with refractory DFU treated in the hospital from January 2015 to January 2017 were divided into the trial group (n=40) and the control group (n=40) by the random number table method. The patients in the two groups were given routine treatment, and on the basis, the patients in the control group were treated with the intelligent trauma negative-pressure comprehensive therapeutic instrument while the ones in the trial group were treated with APG combined with intelligent trauma negative-pressure therapeutic instrument alternately. All patients were observed for 12 weeks. The cure rates, healing time and changes of wound volumes in the two groups before treatment and at 2, 4, 8, and 12 weeks after treatment were recorded. Results The total effective rate of treatment in the trial group was higher than that in the control group (87.5% vs. 67.5%, P<0.05). The wound volumes in the two groups at 4, 8 and 12 weeks after treatment were smaller than those before treatment and at 2 weeks after treatment (P<0.05). The wound volumes in the trial group at 4, 8 and 12 weeks after treatment were significantly smaller than those in the control group (P<0.05). The healing times of Wagner Ⅱ and Ⅲ DFU in the trial group were significantly shorter than those in the control group [(24.71±4.29)vs. (33.84±6.09) days, P<0.05; (33.04±5.97)vs. (45.29±7.05) days, P<0.05]. Conclusion Alternate treatment with APG combined with intelligent trauma negative-pressure comprehensive therapeutic instrument for refractory DFU can promote wound healing, shorten wound healing time, and improve the clinical efficacy.

          Release date:2018-11-22 04:28 Export PDF Favorites Scan
        40 pages Previous 1 2 3 ... 40 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜