ObjectiveTo evaluate the changes of left ventricular structure and function by echocardiography and its grading of left ventricular diastolic function in patients with mitral valve prolapse treated by minimally invasive mitral valve repair.MethodsBy retrospective analysis, 37 patients including 25 males and 12 females aged 53.49±11.02 years with mitral valve prolapse who underwent minimally invasive mitral valve repair were as an operation group, and 34 healthy persons including 19 males and 15 females aged 54.26±8.33 years matched by age and sex were selected as a control group. Ultrasound parameters of every participant were routinely collected before operation, 1 month, 3 months, 6 months and 1 year after operation, and left ventricular diastolic function was graded. The ultrasound parameters between the two groups were compared.ResultsThe diameters of left ventricular end systolic and diastolic phase, left atrial diameter and left ventricular volume in the operation group were significantly smaller than those before operation. The diameters of left ventricle and left atrium after operation were significantly shorter than those before operation, but they were still larger than those of the control group. The ejection fraction value decreased significantly at one month after the operation and then returned to normal level. The incidence of left ventricular diastolic dysfunction at 6 months and 1 year after operation was significantly lower than that before operation (P<0.05).ConclusionMinimally invasive repair for patients with mitral valve prolapse can significantly improve systolic and diastolic functions of left ventricle while reconstructing left atrial and left ventricular structures.
Objective To compare the clinical outcomes and safety of minimally invasive and routine mitral valve repair or replacement for patients with single mitral valve disease. Methods We retrospectively analyzed the clinical data of 67 patients with single mitral valve disease (without aortic valve and tricuspid valve lesion or other heart diseases including atrial septal defect) who underwent mitral valve repair or replacement in the First Affiliated Hospital of China Medical University between January and July 2011. The patients were divided into two groups according to different surgical approaches:the minimally invasive surgery group (n=29,8 males and 21 females,age 51.4±9.4 years) underwent minimally invasive mitral valve repair or replacement via right mini-thoractomy;and the routine surgery group (n=38,11 males and 27 females,age 53.6±11.9 years) underwent mitral valve repair or replacement via middle sternotomy. In the minimally invasive surgery group,9 patients underwent mitral valve repair while the other 20 patients underwent mitral valve replacement. And no patient underwent transition to routine operation. In the routine surgery group,15 patients underwent mitral valve repair and 23 patients underwent mitral valve replacement. Clinical outcomes and safety of the operations were compared between the two groups. Results There was no statistical difference in operation time between the two groups (207.9±18.1 min versus 198.4±27.5 min,P=0.076). The amount of postoperative drainage (126.7±34.5 ml versus 435.6±87.2 ml,P=0.000) and blood transfusion (red blood cell 1.4±0.8 U versus 2.3±1.1 U,P=0.000;blood plasma 164.3±50.4 ml versus 405.6±68.9 ml,P=0.000) of the minimally invasive surgery group were significantly lower than those of the routine surgery group. The cardiopulmonary bypass time (81.7±23.9 min versus 58.7±13.6 min,P=0.000) and aortic-clamping time (51.6±12.7 min versus 38.4±11.7 min,P=0.000) of the minimally invasive surgery group were significantly longer than those of the routine surgery group. The length of ICU stay (22.5±3.6 h versus 31.7±8.5 h,P=0.000),mechanical ventilation (7.4±3.2 h versus 11.2±5.1 h,P=0.000) and postoperative hospitalization (7.1±1.6 d versus 13.5±2.4 d,P=0.000) of the minimally invasive surgery group were significantly shorter than those of the routine surgery group. There was no statistical difference in postoperative complications between the two groups. Minimally invasive surgery group patients were followed up for 5.3±2.4 months with a follow-up rate of 72.4%(21/29). Routine surgery group patients were followed up for 5.5±3.8 months with a follow-up rate of 71.0%(27/38). There was no significant complication during follow-up in both two groups. Conclusion Minimally invasive mitral valve operation via right mini-thoracotomy is effective and safe with a good cosmetic result. Compared with routine operation,patients undergoing minimally invasive operation recover better and faster.
With the expanding indications for transcatheter aortic valve replacement (TAVR) guidelines, combined valvular disease is often encountered in the clinic, and existing relevant studies have shown that preoperative moderate to severe mitral regurgitation is associated with higher mortality. In these patients, the optimal treatment strategy for TAVR with evidence-based heart failure, TAVR with transcatheter mitral intervention, or staging transcatheter therapy are unclear. Therefore, a comprehensive assessment of the anatomy and function of the aortic and mitral valves, as well as an in-depth assessment of the patient’s baseline risk profile, are the basis for an individualized approach to treatment. This article will review the results of the relevant research to better help clinicians diagnose and treat relevant patients.
In recent years, transcatheter mitral valve replacement is a focused issue in the field of valve intervention, which brings hope to mitral regurgitation patients who are not suitable for surgical thoracotomy. This paper presents the case of echocardiography-guided transseptal mitral valve replacement with the HighLife system in an elderly female patient with severe mitral regurgitation who failed to respond to standard medical therapy. During the procedure, echocardiography was used to guide the wire looping, cinching, atrial septal puncture, ring closure, atrial septal balloon dilatation, prosthetic valve implantation and immediate postoperative evaluation. Echocardiography plays an important role in transseptal mitral valve replacement, which can help the procedural process and improve the safety of the procedure.
Minimally invasive cardiac surgeries are the trend in the future. Among them, robotic cardiac surgery is the latest iteration with several key-hole incision, 3-dimentional visualization, and articulated instrumentation of 7 degree of ergonomic freedom for those complex procedures in the heart. In particular, robotic mitral valve surgery, as well as coronary artery bypass grafting, has evolved over the last decade and become the preferred method at certain specialized centers worldwide because of excellent results. Other cardiac procedures are in various stages of evolution. Stepwise innovation of robotic technology will continue to make robotic operations simpler, more efficient, and less invasive, which will encourage more surgeons to take up this technology and extend the benefits of robotic surgery to a larger patient population.
ObjectiveTo evaluate the safety and efficacy of mitral valve surgery and cryoablation in elderly patients with mitral valve disease and persistent or long-term persistent atrial fibrillation.MethodsFrom May 2014 to July 2018, 144 patients with mitral valve diseases combined with persistent or long-term persistent atrial fibrillation in the Department of Cardiothoracic Surgery, General Hospital of Northern Theater Command were selected. Among them, there were 69 patients in a non-elderly group (<60 years) including 18 males and 51 females aged 52.07±5.56 years, and 75 patients in an elderly group (≥60 years) including 32 males and 43 females aged 65.23±4.29 years. A propensity-score matching (PSM) study was conducted to eliminate confounding factors. Both groups underwent mitral valve surgery and cryoablation at the same time. A 2-year follow-up was conducted after discharge from the hospital, and the perioperative and postoperative efficacy indexes were compared between the two groups.ResultsAfter PSM analysis, there were 56 patients in each group. The sinus rhythm conversion rate of the two groups at each follow-up time point was above 85%, and the cardiac function was graded asⅠorⅡ, which was significantly improved compared with that before the surgery, but there was no statistical difference between the two groups (P>0.05). Among the perioperative indicators of the two groups, the elderly group had more coronary artery bypass graft surgeries and longer postoperative ICU stay time compared with the non-elderly group (P<0.05), and the differences in other indicators were not statistically different (P>0.05).ConclusionThe mitral valve surgery and cryoablation in elderly patients with mitral valve diseases combined with persistent or long-term persistent atrial fibrillation are safe, and the short-term outcome is satisfactory.
Objective To investigate and evaluate the safety and effectiveness of the Chimney technique in mitral valve reoperation. Methods The clinical data of mitral valve reoperation patients who underwent Chimney surgery in Wuhan Asia Heart Hospital from 2019 to 2021 were retrospectively analyzed. Results A total of 26 patients were collected, including 7 males and 19 females, aged 27-67 (53.46±11.18) years. All patients had previous mitral valve surgery, including 23 mitral valve replacements and 3 mitral valve repairs. All patients received Chimney technique using the ideal artificial sized mitral valve, and 1 patient died of neurological complications in hospital. The cardiopulmonary bypass time and the aortic cross-clamping time were 231.11±77.05 min and 148.50±52.70 min, respectively. The mean diameter of the implanted mitral valve prosthesis was 29.08±0.68 mm, which was statistically different from pre-replacement valve prosthesis size of 26.69±0.77 mm (P<0.001). The mean transvalvular pressure gradient of the prosthetic mitral valve measured on postoperative echocardiography was 14.77±5.34 mm Hg, which was statistically different from preoperative value of 20.92±9.83 mm Hg (P=0.005). Conclusion The Chimney technique is safe and effective for reoperation in patients with small mitral annuli, which can not only reduce the risk of reoperation, but also obtain larger prosthetic valve implants with good hemodynamic characteristics and clinical outcomes.
ObjectiveTo analyze the early and mid-term safety and effectiveness of concomitant cryosurgical Cox-Maze Ⅳ procedure in minimally invasive mitral valve surgery.MethodsWe retrospectively reviewed the clinical data of 68 patients (28 males and 40 females with a mean age of 38.7±9.3 years) who underwent concomitant cryosurgical Cox-Maze Ⅳ procedure in minimally invasive mitral valve and tricuspid surgery in the Department of Cardiovascular Surgery of the Second Xiangya Hospital from August 2013 to October 2017. The heart rhythm of the patients after surgery was supervised by 24 hour holter monitoring eletrocardiogram.ResultsNo death occurred during operation and follow-up. One patient underwent reexploration for bleeding. The rate of sinus rhythm restored at the time of discharge was 95.8%. The rate of sinus rhythm restored at 6 months, 12 months, 24 months, 36 months after surgery was 93.5%, 91.6%, 90.3% and 89.5% respectively.ConclusionConcomitant cryosurgical Cox-Maze Ⅳ procedure in minimally invasive mitral valve surgery is quite safe and effective in treatment of rheumatic mitral valve disease and atrial fibrillation in the early and mid-term follow-up.
Mitral valve disease is the most common cardiac valve disease. The main treatment of mitral valve disease is surgery or interventional therapy. However, as the anatomy of mitral valve is complicated, the operation is particularly difficult. As a result, it requires sophisticated experiences for surgeons. Three-dimensional (3D) printing technology can transform two-dimensional medical images into 3D solid models. So it can provide clear spatial anatomical information and offer safe and personalized treatment for the patients by simulating surgery process. This article reviews the applications of 3D printing technology in the treatment of mitral valve disease.
Mitral regurgitation is the most common heart valvular disease at present. In the past, mitral regurgitation was mainly treated by surgical mitral valve repair or replacement. However, with the progress of transcatheter interventional techniques and instruments in recent years, transcatheter mitral valve interventional therapy has gradually shown its advantages and benefited patients. The purpose of this article is to review the progress of transcatheter mitral valve intervention in this year, and to provide prospects for the future of transcatheter mitral valve treatment.