ObjectiveTo investigate the feasibil ity of the domestic porous tantalum as scaffold material of bone tissue engineering by observing the expressions of osteogenesis related factors of MG63 cells co-cultured with domestic porous tantalum. MethodsMG63 cells were cultured with porous tantalum scaffolds (group A), with porous tantalum leaching solution (group B), and with MEM as control group (group C). The cell adhesion of group A was observed on the scaffolds at 3, 5, and 7 days after culture by scanning electron microscopy (SEM); immunohistochemistry and Western blot methods were used to detect the expressions of Runt-related transcri ption factor 2 (Runx-2), osteocalcin (OC), and fibronectin (FN). ResultsAt 3 days after culture, the cells of group A adhered the surface and pore of the porous tantalum scaffolds, with sparse cell arrangement and less protuberances; at 5 days after culture, adjacent cells connected to be a flat each other, which covered the surface and pore of the scaffold; at 7 days after culture, cells secreted plenty of extracellular matrix, covering most of the material surface. The expressions of Runx-2, OC, and FN were positive in 3 groups; darker staining of the cytoplasm was observed in group A, the expressions were significantly higher in group A than in other 2 groups. The results of immunohistochemistry and Western blot showed that the expressions of Runx-2 and OC were significantly increased in group A when compared with those in groups B and C (P < 0.05), but no significant difference was found between groups B and C (P > 0.05). The expression of FN had no significant difference among 3 groups (P > 0.05). ConclusionDomestic porous tantalum could promote MG63 cells adhesion and growth, and may promote the expressions of Runx-2 and OC, so it can be used as a scaffold material of bone tissue engineering.
In recent years, reports of domestic robot-assisted total knee arthroplasty have gradually increased. In response to problems that may arise during the perioperative period, West China Hospital of Sichuan University has adopted measures such as the establishment of multidisciplinary team, adequate preoperative evaluation, precise intraoperative operations, and whole process optimization management (incision management, pain management, functional exercise and follow-up management). Combined with the actual clinical situation, a domestic robot-assisted total knee arthroplasty management program during the perioperative period was explored and formulated to promote the recovery of patients. This article introduces the above-mentioned program, and aims to provide a reference for the management optimization of domestic robot-assisted total knee arthroplasty during the perioperative period.
ObjectiveTo evaluate the clinical efficacy of domestic minimally-invasive percutaneous screw system for thoracolumbar fractures without neurological damage. MethodsSixty patients suffering from unstable thoracolumbar fractures without obvious neurologic deficits treated from January 2011 to April 2012 were studied retrospectively. The patients were divided into two groups:group A (domestic minimally-invasive percutaneous screw system) and group B (imported minimally-invasive percutaneous screw system). Perioperative parameter, pre-and post-operative imaging indexes, visual analog scale (VAS) and modified MacNab evaluation standard were studied for comparison. ResultsAll the patients were followed up from 6 to 18 months with an average of (12.2±3.0) months. The Cobb's angle and anterior height of the fracture vertebral body changed significantly in each group (P<0.05). There was no significant difference in incision size, surgical time, postoperative improvement of Cobb's angle, anterior height of the fracture vertebral body and accuracy of pedicle screw placement between the two groups (P>0.05). ConclusionDomestic minimally-invasive percutaneous screw system is reliable with minimal invasion, which is comparable to imported minimally-invasive percutaneous screw system.
Transcatheter aortic valve replacement (TAVR) as a mature technology has been widely applied in Western countries. In China, with the first two domestic prostheses being approved for commercial use, the technology now is expecting a fast development. In this article, we reviewed the features of Chinese aortic stenosis patients, the early Chinese experience of TAVR, the application of domestic prostheses and remaining problems.
As the largest ecosystem of human body, intestinal microorganisms participate in the synthesis and metabolism of uric acid. Developing and utilizing intestinal bacteria to degrade uric acid might provide new ideas for the treatment of hyperuricemia. The fecal samples of people with low uric acid were inoculated into uric acid selective medium with the concentration of 1.5 mmol/L for preliminary screening, and the initially screened strains that may have degradation ability were domesticated by concentration gradient method, and the strains with high uric acid degradation rate were identified by 16S rRNA sequencing method. A strain of high-efficiency uric acid degrading bacteria was screened and domesticated from the feces of people with low uric acid. The degradation rate of uric acid could reach 50.2%. It was identified as Escherichia coli. The isolation and domestication of high efficient uric acid degrading strains can not only provide scientific basis for the study of the mechanism of intestinal microbial degradation of uric acid, but also reserve biological strains for the treatment of hyperuricemia and gout in the future.
ObjectiveTo explore the application of Toumai? minimally invasive endoscopic robot in thoracic surgery, and to observe its safety and short-term surgical efficacy. MethodsThree patients were enrolled from October to December 2021, including 1 male (69 years) and 2 females (47 years and 22 years). All 3 patients received surgery with Toumai? endoscopic surgical robot, including radical lung cancer surgery in 2 patients and mediastinal tumor resection in 1 patient. ResultsAll 3 patients were successfully operated without conversion to thoracotomy, complication or death. For the male lobectomy patient, the total operation time was 120 min, the intraoperative blood loss was 100 mL, the catheter drainage time was 4 days and the hospital stay time was 5 days. For the female lobectomy patient, the total operation time was 103 min, the intraoperative blood loss was 100 mL, the catheter drainage time was 4 days and the hospital stay time was 5 days. For the female mediastinal tumor patient, the total operation time was 81 min, the intraoperative blood loss was 50 mL, the catheter drainage time was 3 days and the hospital stay time was 3 days. ConclusionThe Toumai? minimally invasive endoscopic surgical robot is safe and effective in thoracic surgery. Compared with Da Vinci surgical robot, Toumai? has the same 3D visual field experience and smooth operation.
ObjectiveTo evaluate the performance, including stability and cutting efficiency, of a domestically produced S model dual-blade, dual-port vitrectomy probe during vitrectomy surgery. MethodsA prospective, randomized controlled, non inferiority, multicenter clinical trial study. 120 patients who underwent PPV treatment at Xiamen Eye Center, Department of Ophthalmology of Peking University People’s Hospital, and Department of Ophthalmology, Peking University International Hospital in August 2025 were included in the study. According to the cutting frequency and instrument source, they are divided into 4 groups: 10 k cpm domestic S-type vitrectomy probe group, imported A-type vitrectomy probe group, and 20 k cpm S-type vitrectomy probe group and A-type vitrectomy probe group, with 30 cases in each group. The S-type vitrectomy probe adopts a double-edged dual air path design at frequencies of 10 and 20 k cpm; The A-type vitrectomy probe has a single blade design at a frequency of 10 k cpm and a double-edged design at a frequency of 20 k cpm. Compare and observe the differences in cutting efficiency, safety (incidence of iatrogenic retinal tears), and equipment stability (bubble generation, frequency and negative pressure changes, defect detection) between two groups. The comparison between groups was conducted using the chi square test. ResultsDue to missing data from one patient in the 20 k cpm S-type vitrectomy probe group, 119 cases were ultimately included in the statistical analysis. Among them, there were 59 cases in the S-type probe group (30 cases at 10 k cpm and 29 cases at 20 k cpm), and 60 cases in the A-type probe group (30 cases at 10 k cpm and 20 k cpm each). There was no significant difference in age, sex composition ratio, eye type, whether to combine cataract surgery, anesthesia mode, disease classification, proliferative vitreoretinopathy and proliferative membrane grading of proliferative diabetes retinopathy between 10 k cpm, 20 k cpm S-type vitrectomy probe group and A-type vitrectomy probe group (P>0.05). There was no statistically significant difference in cutting efficiency, cutting safety, equipment stability, frequency and negative pressure fluctuation amplitude, and defect detection between the two groups (P>0.05). In terms of bubble generation in equipment stability, the 20 k cpm S-type vitrectomy probe group performed significantly better than the A-type vitrectomy probe group, and the difference was statistically significant (P=0.027). ConclusionThe domestic S-type vitrectomy probe is non-inferior to the imported A-type vitrectomy probe across multiple performance indicators and shows superior anti-bubble performance.