ObjectiveTo compare the effectiveness of the arthroscopic anterior cruciate ligament (ACL) reconstruction with the transtibial technique and through anteromedial approach. MethodsBetween April 2008 and May 2012, 86 patients (86 knees) with ACL rupture underwent single bundle reconstruction with autogeneic hamstring tendons with the transtibial technique in 44 cases (group A) and through anteromedial approach in 42 cases (group B). There was no significant difference in age, gender, injury causes, injury to admission time, preoperative International Knee Documentation Committee (IKDC) score, and Lysholm score between 2 groups (P>0.05). The femoral and tibia tunnels were measured by X-ray films and CT. The knee stability and function were evaluated by Lachman test, pivot shift test, IKDC score, and Lysholm score. ResultsThe patients were followed up 1-2 years (mean, 1.5 years) in group A and 1 year-1 year and 6 months (mean, 1.2 years) in group B. No limitation of knee motion was observed. The Lysholm score and IKDC score were significantly increased at 1 year after operation when compared with preoperative scores in 2 groups (P<0.05), but no significant difference was found between 2 groups (P>0.05). At 1 year after operation, the stability of the knee in group B was significantly better than that in group A, and the results of Lachman test and pivot shift test showed significant differences between 2 groups (P<0.05). The femoral tunnel in group A was significantly longer in length and bigger in coronal angles and sagittal location than that in group B (P<0.05). ConclusionACL reconstruction through anteromedial approach is a surgical technique to be closer to anatomy reconstruction, which can obtain better rotation function and stability of the knee than the transtibial technique.
Objective To study the feasibility of virtual intercondylar notchplasty by applying MRI two-dimensional (2D) images to reconstruct three-dimensional (3D) images and measure the size of intercondylar notch. Methods Thirty healthy volunteers who had no knee joint disease and surgery history were selected. There were 15 females and 15 males with an age range of 20-30 years, weight range of 45-74 kg, and height range of 150-185 cm. They were divided into male group and female group, and the knees of each group were divided into 2 subgroups (the left group and right group). MRI scan of the left and right knees was performed, and the 2D images of MRI were imported into Mimics10.01 medical image control system for 3D reconstruction. The related anatomical data as follows were measured from the 3D digital model and analyzed by statistical software: notch width (NW), condylar width (CW), and notch width index (NWI). Then the 3D knee images of patients with anterior cruciate ligament (ACL) injury were collected between January and March 2010, and 4 patients with narrow intercondylar notch (NWI≤0.2) were selected for reconstructing the 3D model of the knee and simulating the intercondylar notch plasty. Then, the volume of osteotomy in 3D model was calculated and applied in the ACL reconstruction surgery, and whether the graft had impingement with intercondylar notch or not was evaluated. Results There were significant differences in NW and CW between male group and female group (P≤lt;≤0.05), but no significant difference was found in the NWI (P≤gt;≤0.05). And there was no significant difference in NW, CW, and NWI between the left and right knees both in male group and female group (P≤gt;≤0.05). After ACL reconstruction and intercondylar notchplasty, the shape of intercondylar notch became normal (NWI≤gt;≤0.22), no impingement occurred between the graft and intercondylar notch under arthroscopy within 3-month follow-up. Conclusion The shape of intercondylar notch of 3D model based on MRI 2D images is similar to the real intercondylar notch. NWI is one of important indexes which can reflect the narrow level of intercondylar notch. The virtual intercondylar notchplasty may provide preoperative plan and guidence for ACL reconstruction operation to avoid the impingement between graft and intercondylar notch after surgery.
Objective To summarize the evaluation methods of return to sports (RTS) after anterior cruciate ligament reconstruction (ACLR) in recent years, in order to provide reference for clinical practice. Methods The literature related to the RTS after ACLR was searched from CNKI, Wanfang, PubMed, and Foreign Medical Information Resources Retrieval Platform (FMRS) databases. The retrieval range was from 2010 to 2023, and 66 papers were finally included for review. The relevant literature was summarized and analyzed from the aspects of RTS time, objective evaluation indicators, and psychological evaluation. Results RTS is the common desire of patients with ACL injury and doctors, as well as the initial intention of selecting surgery. A reasonable and perfect evaluation method of RTS can not only help patients recover to preoperative exercise level, but also protect patients from re-injury. At present, the main criterion for clinical judgement of RTS is time. It is basically agreed that RTS after 9 months can reduce the re-injury. In addition to time, it is also necessary to test the lower limb muscle strength, jumping, balance, and other aspects of the patient, comprehensively assess the degree of functional recovery and determine the different time of RTS according to the type of exercise. Psychological assessment plays an important role in RTS and has a good clinical predictive effect. ConclusionRTS is one of the research hotspots after ACLR. At present, there are many related evaluation methods, which need to be further optimized by more research to build a comprehensive and standardized evaluation system.
ObjectiveTo prepare the small intestinal submucosa (SIS)-silk composite scaffold for anterior cruciate ligament (ACL) reconstruction, and to evaluate its properties of biomechanics, biocompatibility, and the influence on synovial fluid leaking into tibia tunnel so as to provide a better choice in the clinical application of ACL reconstruction. MethodsThe silk was used to remove sericin and then weaved as silk scaffold, which was surrounded cylindrically by SIS to prepare a composite scaffold. The property of biomechanics was evaluated by biomechanical testing system. The cell biocompatibility of scaffolds was evaluated by live/dead staining and the cell counting kit 8 (CCK- 8). Thirty 6-week-old Sprague Dawley rats were randomly assigned to 2 groups (n=15). The silk scaffold (S group) and composite scaffold (SS group) were subcutaneously implanted. At 2, 4, and 8 weeks after implanted, the specimen were harvested for HE staining to observe the biocompatibility. Another 20 28-week-old New Zealand white rabbits were randomly assigned to the S group and SS group (n=20), and the silk scaffold and composite scaffold were used for ACL reconstruction respectively in 2 groups. Furthermore, a bone window was made on the tibia tunnel. At last, the electric resistance of tendon graft in the bone window was measured and recorded at different time points after 5 mL of 10% NaCl or 5 mL of ink solution was irrigated into the joint cavity recspectively. ResultsThe gross observation showed that the composite scaffold consisted of the helical silk bundle inside which was surrounded by SIS. The maximal load of silk scaffold and composite scaffold was respectively (138.62±11.41) N and (137.05±16.95) N, showing no significant difference (P>0.05); the stiffness was respectively (24.65±2.62) N/mm and (24.21±2.39) N/mm, showing no significant difference (P>0.05). The live/dead staining showed that the cells had good activity on both scaffolds. However, the cells on the composite scaffold had better extensibility. In addition, the cell proliferation curve indicated that no significant difference in the absorbance (A) values was founded between groups at various time points (P>0.05). HE staining showed less inflammatory cells and much more angiogenesis in SS group than in S group at 2, 4, and 8 weeks after subcutaneously implanted (P<0.05), indicating good biocompatibility. Additionally, the starting time points of electric resistance decrease and the ink leakage were both significantly later in SS group than in S group (P<0.05). The duration of ink leakage was significantly longer in SS group than in S group (P<0.05). ConclusionThe SIS-silk composite scaffold has excellent biomechanical properties and biocompatibility and early vacularization after in vivo implantation. Moreover, it can reducing the leakage of synovial fluid into tibia tunnel at the early stage of ACL reconstruction. So it is promising to be an ideal ACL scaffold.
ObjectiveTo study the analgesia and rehabilitation effect of femoral nerve block after anterior cruciate ligament reconstruction (ACLR). MethodsDuring June to September 2014, 62 patients who were scheduled to undergo ACLR were randomly divided into two groups:femoral nerve block group (n=31) and control group (n=31). All the patients were given celecoxib 200 mg (twice per day) three days before surgery. Patients in the femoral nerve block group were given a single-injection femoral nerve block (SFNB) half an hour before surgery (ropivacaine 0.75%, 30 mL), Both of the two groups underwent ice therapy after surgery. The visual analogue scale (VAS) scores, knee joint range of motion, the muscle strength of quadriceps femoris, the side effects, complications and infection rate were recorded after the operation. ResultsThe VAS scores were significantly lower in the femoral nerve block group within 2 hours to 7 days after surgery (P<0.05), and the use of morphine was less than the control group in all the time points with statistical significance (P<0.05). The muscle strength of quadriceps femoris was significantly weaker in the femoral nerve block group than the control group in the first 12 hours (P<0.05). The side effects and infection rate between the two group had no significant difference (P>0.05). ConclusionThe femoral nerve block in anterior cruciate ligament reconstruction before surgery has a good effect on postoperative analgesia and rehabilitation, which is worth popularizing and applying.
ObjectiveTo evaluate the correlation between the Mohawk (MKX) expression level and the collagen fiber diameter of autologous hamstring tendon graft during the stable graft remodeling phase after anterior cruciate ligament (ACL) reconstruction.MethodsBetween January 2018 and August 2018, patients who underwent arth-roscopic single-bundle anatomical ACL reconstruction with autologous hamstring tendons for at least 48 months and also underwent second-look arthroscopy were enrolled in study. During the second-look arthroscopic procedures, ACL graft biopsies were performed from the surface of central part of the ligament. MKX expressions of ACL grafts were analysed by real-time fluorescent quantitative PCR (qRT-PCR). The ultrastructure of collagen fibers of grafts were evaluated by transmission electron microscopy, which included average diameter of collagen fibers (Dc), average diameter of large-diameter collagen fibers (DL), average diameter of small-diameter collagen fibers (DS), and large-small collagen fibers ratio (RL/S). The correlation between MKX expression level and graft collagen fiber diameter was calculated.ResultsTwenty-six patients met the selection criteria and their ACL graft specimens were enrolled in the study. The interval between ACL reconstruction and second-look arthroscopy was 52-128 months, with an average of 78.6 months. Arthroscopic graft remodeling score was 3-6 (mean, 4.8). There were 17 cases of excellent remodeling and 9 cases of fair remodeling. All ACL grafts showed typical bimodal distributions of both large-diameter collagen fibers and small-diameter collagen fibers, but the ultrastructural characteristics of the graft collagen fibers were different according to different remodeling status under arthroscopy. The DC, DL, DS, and RL/S of the graft specimens were (65.2±9.3) nm, (91.6±10.5) nm, (45.7±8.6) nm, and 0.73±0.12, respectively. The relative expression level of MKX was 1.42±0.11, which was positively linearly correlated with DC, DL, and RL/S, and the correlation coefficient was statistically significant (r=0.809, P=0.000; r=0.861, P=0.000; r=0.942, P=0.000), while there was no significant correlation between DS and relative expression level of MKX (r=0.147, P=0.238). Regression analysis showed that the relative expression level of MKX could predict the DC, DL, and RL/S results of the ACL graft specimens (P<0.05).ConclusionAfter autologous hamstring tendon grafts stepped into stabilized remodeling phase, MKX expression level could predict the diameter measurement results of collagen fibers and be used as an important evaluation basis for graft collagen anabolic metabolism.
Objective To compare the recovery of proprioception between autograft and allograft for anterior cruciate l igament (ACL) reconstruction. Methods Between January 2008 and January 2010, 40 patients underwent ACL reconstruction with autologous tendon (autograft group, n=20) and allogeneic tendon (allograft group, n=20). No significant difference was found in gender, age, disease duration, and function scores between 2 groups (P gt; 0.05). All the patients underwent the ACL reconstruction with single-bundle technique. The knee range of motion (ROM), International Knee Documentation Committee (IKDC) score, and Lysholm score were measured after operation. The proprioception was assessedby the joint position sense (JPS) at 3 and 12 months postoperatively. The normal knee was used as control. Results Thepatients of 2 groups achieved heal ing of incision by first intention without compl ication of infection or haemarthrosis. Allpatients were followed up 12-18 months (mean, 13.5 months). There were significant differences in knee ROM, IKDC score, and Lysholm score between preoperation and 12 months postoperatively in 2 groups (P lt; 0.05). There was no significant difference in JPS 30°, JPS 60°, and JPS 90° between affected knees and normal knees in autograft group at 3 months postoperatively (P gt; 0.05). No significant difference was found in JPS 30° between affected knees and normal knees in allograft group at 3 months postoperatively (P gt; 0.05); but significant differences were found in JPS 60° and JPS 90° between affected knees and normal knees in allograft group at 3 months postoperatively (P lt; 0.05). There was no significant difference in JPS 30°, JPS 60°, and JPS 90° between affected knees and normal knees in 2 groups at 12 months postoperatively (P gt; 0.05). Significant differences were also found in JPS 60° and JPS 90° between affected knees of 2 groups (P lt; 0.05) at 3 months postoperatively, whereas no significant difference was found in JPS 30° between affected knees of 2 groups (P gt; 0.05). No significant difference was found in JPS 30°, JPS 60°, and JPS 90° between affected knees of 2 groups at 12 months postoperatively (P gt; 0.05). Conclusion Autologous andACL reconstruction is better than allogeneic ACL reconstruction in the recovery of proprioception at early time after surgery.
ObjectiveTo review the current status and progress of sterilization and preservation for allograft in anterior cruciate ligament reconstruction.MethodsThe related literature about the sterilization and preservation of allografts in anterior cruciate ligament reconstruction was extensively reviewed and summarized.ResultsThere are many sterilization methods for allografts, the most commonly used method is γ-ray irradiation, but the optimal irradiation dose is still unclear. Electron beam irradiation is also available, but excessive dose is harmful to graft shaping. A combined sterilization method combining physics and chemistry methods is still being explored. Cryopreservation is the most commonly used method of preservation. In order to reduce the influence of crystals, the principle of " slow cooling and rapid rewarming” should be adhered to as far as possible.ConclusionThe processing methods of allograft can affect the effectiveness of anterior cruciate ligament reconstruction. The clinical doctors should consider the sterilization and preservation methods in practice.
ObjectiveTo summarize the early postoperative pain management strategies for anterior cruciate ligament reconstruction (ACLR), and to select a reasonable and effective pain management plan to promote functional rehabilitation after ACLR. MethodsThe literature about the early postoperative pain management strategies of ACLR both domestically and internationally in recent years was extensiverly reviewed, and the effects of improving postoperative pain were reviewed. ResultsCurrently, physical therapy and oral medication have advantages such as economy and simplicity, but the effect of improving postoperative pain is not satisfactory, often requires a combination of intravenous injection or intravenous pump, which is also a common way to relieve pain. However, in order to meet the analgesic needs of patients, the amount of analgesic drugs used is often large, which increases the incidence of various adverse reactions. Local infiltration analgesia (LIA), including periarticular or intra-articular injection of drugs, can significantly improve the early postoperative pain of ACLR, and achieve similar postoperative effectiveness as nerve block. LIA can be used as an analgesic technique instead of nerve block, and avoid the corresponding weakness of innervated muscles caused by nerve block, which increases the risk of postoperative falls. Many studies have confirmed that LIA can alleviate postoperative early pain in ACLR, especially the analgesic effects of periarticular injection are more satisfactory. It can also avoid the risk of cartilage damage caused by intra-articular injection. However, the postoperative analgesic effect and timeliness still need to be improved. It is possible to consider combining multimodal mixed drug LIA (combined with intra-articular and periarticular) with other pain intervention methods to exert a synergistic effect, in order to avoid the side effects and risks brought by single drugs or single administration route. LIA is expected to become one of the most common methods for relieving postoperative early pain in ACLR. ConclusionEarly pain after arthroscopic ACLR still affects the further functional activities of patients, and all kinds of analgesic methods can achieve certain effectiveness, but there is no unified standard at present, and the advantages and disadvantages of various analgesic methods need further research.
Objective To investigate the effectiveness of portable bracket of lower limb in the reconstruction of anterior cruciate l igament (ACL) by the long fibular muscle tendon under arthroscopy. Methods Between March 2008 and September 2010, 22 patients with ACL injury were treated. The limb position was maintained by portable bracket of lower limb and ACL was reconstructed with the long fibular muscle tendon under arthroscopy. There were 15 males and 7 females with an average age of 33.8 years (range, 19-64 years). The causes of ACL injury were traffic accident injury in 14 cases, sport trauma in 5 cases, and fall ing injury in 3 cases. The locations were the left knee in 10 cases and the right knee in12 cases, including 12 fresh injuries and 10 old injuries. Of 22 patients, 17 had positive anterior drawer test, 19 had positive pivot shift test, and 20 had positive Lachman test. According to International Knee Documentation Committee (IKDC) criteria, there were 6 abnormal and 16 severely abnormal. The subjective IKDC score was 57.64 ± 6.11. The Lysholm score was 55.45 ± 4.37. Results All incisions healed by first intention, and no complication was found. All patients were followed up 9-38 months (mean, 15 months). At last follow-up, the flexion of the knee ranged from 120 to 135° (mean, 127°). One patient had positive anterior drawer test, 1 patient had positive pivot shift test, and 2 patients had positive Lachman test. No ligament loosening and breakage occurred. According to the IKDC criteria, 10 patients rated as normal, 11 patients as nearly normal, and 1 patient as abnormal. The subjective IKDC score was 90.44 ± 6.11, showing significant difference when compared with preoperative one (t=4.653, P=0.021). The Lysholm score was 90.12 ± 5.78, showing significant difference when compared with preoperative one (t=4.231, P=0.028). Conclusion Portable bracket of lower limb in the reconstruction of ACL has the advantages of saving manpower and easy operation. The long fibular muscle tendon is enough long and b to reconstruct the ACL, which can increase the contact surface between the tendon and bone and is beneficial to tendon-bone heal ing.