ObjectiveTo study the relation between daily activity that can make right atrium pressure rise (such as abdominal belt, sighs, weight lifting) and patent foramen ovale (PFO). MethodsA total of 122 cases of positive patients by the routine transcranial Doppler (TCD) foaming test between 2014 and 2015 were collected. Forty-one patients underwent TCD foaming test in the case of abdominal belt, 41 in the case of sighs, and 40 in the case of weight lifting. We recorded the right to left shunting of the above three cases, and compared them with the normal TCD foam test. ResultsThere was a significant difference in the positive rate between the sigh group and abdominal belt group, and between the sigh group and weight lifting group (χ2=10.5, 7.40; P<0.01). The positive rate in the abdominal belt group was not significantly different from that of the weight lifting group (χ2=0.314, P>0.05). In the sigh group, the sigh shunting volume was significantly higher than that when the patients were at rest. The shunting volume was the biggest when the patients had Valsalva movement, followed by sighing and resting. ConclusionThe daily activity that can make right atrium pressure rise (such as abdominal belt, sighs, weight lifting) can increase the shunting flow from the right to the left. The highest positive rate occurs when patients sigh. This study can provide a certain theoretical basis for the pathogenesis of patent foramen ovale and cryptogenic stroke.
ObjectiveTo evaluate the continuous half-thickness suture outside of the pectinate muscles in the right atrium incision in adult patients undergoing cardiac surgery. MethodsA total of 1 040 consecutive adult patients undergoing cardiac surgery by the right atrium incision with cardiopulmonary bypass (CPB) were randomly divided into a control group (n=518 with 236 males and 282 females at mean age of 44.55 years) and a trial group (n=522 with 242 males and 280 females at mean age 45.75 years) between January 2010 and June 2014. The right atrium incision was sutured by continuous full-thickness suture in the control group and sutured by continuous half-thickness suture in the trial group. After the suture, the bleeding in the right atrium incision was recorded. ResultsAll patients underwent the open-heart operation. Seven patients died of postoperative low cardiac syndrome including four patients in the control group and 3 patients in the trial group. The heart incision was inspected before suturing the pericardium. A total of 203 patients of local active bleeding were stitched again in the right atrium incision in the control group. Only 26 patients were stitched again in the trial group (P<0.001). In the cases of re-exploration for bleeding or tamponade after cardiac operation, 3 patients of bleeding due to the right atrium incision were confirmed in the control group, and no one was confirmed in the trial group. ConclusionThe continuous half-thickness suture in the right atrium incision can prevent the incision bleeding, and avoid locally stitching again in adult patients undergoing cardiac surgery.
Objective To construct an anatomical pulsatile flow right atrium in vitro evaluation platform to quantify the effects of dialysis flow rate, catheter arteriovenous port spacing, and tip position on the recirculation rate of step-tip dialysis catheters. Methods Based on CT image-derived 3D printed right atrium model, an in vitro pulsatile circulation loop was established. The recirculation rate was measured using dye tracing-ultraviolet spectrophotometry. Results A decrease in dialysis flow rate, an increase in port spacing, and the catheter tip penetrating deeper into the right atrium all increased the recirculation rate. When the arteriovenous port was fixed at 15 mm and the tip was located at the junction of the atrium and ventricle, the recirculation rates were 31.32%±4.06%, 26.49%±3.89%, and 16.17%±4.14% at dialysis flow rates of 100, 200, and 400 mL/min, respectively. When the flow rate was fixed at 400 mL/min, the recirculation rates were 16.17%±4.14%, 17.96%±5.96%, 21.68%±2.11%, and 29.74%±7.11% with the port spacing 15, 20, 25, and 30 mm, respectively. When the spacing was fixed at 15 mm and the catheter tip was moved from the superior vena cava to the right atrium, the recirculation rate increased from 6.93%±1.06% to 21.73%±4.21%. Conclusions The pulsatile fluid external model can accurately quantify the recirculation performance of step-tip catheters. Compared to the steady-state registration standards, the test results are more in line with the real in vivo environment, providing a standardized evaluation method for dialysis catheter registration testing, structural optimization, and clinical catheter placement.