• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "replacement" 529 results
        • A case report of transcatheter aortic valve replacement with descending aorta severe distortion

          An 89 years old male patient was admitted to the First Medical Center of Chinese PLA General Hospital due to chest tightness and shortness of breath for half a month. Severe aortic valve stenosis was found in post admission assessment. We proposed to perform transcatheter aortic valve replacement surgery. Preoperative evaluation showed severe distortion of the descending aorta. We used the double guide wire technique and a 14F long sheath to assist the stepwise balloon expansion, and successfully completed the valve implantation. For patients with severe tortuous aorta, how to successfully complete transcatheter aortic valve replacement, this case may provide some reference.

          Release date:2020-05-26 02:34 Export PDF Favorites Scan
        • Mitral regurgitation during the transcatheter aortic valve replacement of a patient:a case report

          This article described the clinical diagnosis and treatment of a patient with bicuspid aortic stenosis occurring severe mitral regurgitation during transcatheter aortic valve replacement. Before transcatheter aortic valve replacement, the patient’s information about medical history, signs, evaluation of CT and echocardiography were collected. After discussion by the heart team, the trans-femoral aortic valve replacement was performed. After the valve was placed during the procedure, a severe mitral regurgitation occurred. No clear causes were found, and the patient’s hemodynamics was stable. The patient recovered well during follow-up, so surgery and other treatments were not considered. This article discussed the possible mechanism and solutions of mitral regurgitation during transcatheter aortic valve replacement, and owned certain value for similar cases to refer to.

          Release date:2020-05-26 02:34 Export PDF Favorites Scan
        • Reoperation after Mechanical Valve Prosthesis Replacement: An Analysis of 105 Cases

          Abstract: Objective To summarize our operative experiences of cardiac reoperation after mechanical valve prosthesis replacement and investigate the causes of reoperation and the perioperative techniques and operation methods. Methods From January 2001 to December 2008, we performed reoperation on 105 patients (59 males and 46 females, aged 50.2±10.6 years old) who had undergone mechanical valve prosthesis replacement. Among the patients, there were 31 cases of mitral valvular replacement (+ tricuspid valvular plasticity), 38 cases of aortic valvular replacement (+ tricuspid valvular plasticity), 11 cases of Bentall procedure, 7 cases of mitral and aortic bivalvular replacement (+tricuspid valvular plasticity), 8 cases of tricuspid valvular replacement, 6 cases of repairing of prosthetic leakage, and 4 others cases. The time interval between two operations was 3 months to 18 years (46.3 ±31.9 months). Before reoperation, the cardiac function (NYHA) of the patients was class Ⅱ in 27 patients, class Ⅲ in 53 patients, and class Ⅳ in 25 patients. Results There were 6 hospital deaths with a mortality of 5.71%(6/105). All others recovered to NYHA class ⅠⅡ. The causes of mortality included 1 case of multiple organ failure, 1 case of low cardiac output after operation, 1 case of aortic pseudoaneurysm rupture, 1 case of severe infection due to brain complication and 2 cases of prosthetic valve endocarditis (PVE). The causes for cardiac reoperation after mechanical valve prosthesis replacement were 67 cases of prosthetic leakage (63.80%), 16 cases of PVE (15.23%), 14 cases of prosthetic thrombosis (13.33%) and 8 cases of other valvular anomalies. Followup was done for 11 to 107 months, which showed two cases late deaths of cardiac arrest and cerebral hemorrhage. Conclusion Patients who have received mechanical valve prosthesis replacement may undergo cardiac reoperation due to paravalvular prosthetic leakage, paravalvular endocarditis, and prosthetic thrombosis. The keys to a successful cardiac reoperation include appropriate preoperative preparations, operational timing, and suitable choosing of cardiopulmonary bypass and operational skills. 

          Release date:2016-08-30 06:02 Export PDF Favorites Scan
        • EFFECTS OF NOVEL ANGLED CERVICAL DISC REPLACEMENT ON FACET JOINT STRESS

          Objective To analyze the biomechanical changes of the adjacent cervical facet joints when the angled cervical prosthesis is replaced. Methods A total of 400 northwestern people were involved, with an age of 40 years or older.The cervical vertebra lateral X-ray films were taken, and the cervical angles were measured by professional computer aided design software, then the cervical intervertebral disc prosthesis with 10° angle was designed. The finite element models of C4,5and C4-6 segments with intact cervical discs were developed; the C4,5 disc was replaced by the cervical prosthesis with 0° and 10° angle respectively; and then all models were subjected to axial loading, flexion/extension, lateral bending, and torsion loading conditions; the stress effects on adjacent facet joints after replacement were observed by comparing with that of the intact model. Results The cervical angles were (9.97 ± 3.64)° in C3,4, (9.95 ± 4.34)° in C4,5, (8.59 ± 3.75)° in C5,6, and (8.49 ± 3.39)° in C6,7, showing no significant difference between C3,4 and C4,5, C5,6 and C6,7 (P gt; 0.05) and showing significant differences between the other cervical angles (P lt; 0.05). When C4,5 model was axially loaded, no significant difference in equivalent shearing stress were observed in intact, 0°, and 10° groups; at flexion/extension loading, the stress was biggest in intact group, and was smallest in 10° group; at lateral bending, the stress got the high rank in intact group, and was minimum in 10° group; at torsion loading, the stress state of 10° group approached to the intact one condition. When C4-6 model was loaded, the facet joint stress of the replaced segment (C4,5) decreased significantly at axial loading, flexion/extension, and lateral bending; while no obvious decrease was observed at torsion loading; the stress of the adjacent inferior disc (C5,6) decreased significantly at axial loadingand lateral bending condition, while less decrease was observed at torsion loading, no significant change at flexion/extension condition, it approached to that of the intact one. Conclusion The finite element analysis reveals that the biomechanical properties of 10° designed prosthesis is approximate to that of the intact cervical disc, thus the 10° designed prosthesis can meet the requirements of biomechanical function reconstruction of the cervical spine.

          Release date:2016-08-31 04:23 Export PDF Favorites Scan
        • Clinical Characteristics and Management of Patients with Severe Tricuspid Regurgitation after Mitral Valve Surgery

          Objective To summarize the clinical characteristics and management experiences of patients with severe tricuspid regurgitation (TR) after mitral valve surgery. Methods Thirty patients were followed up and reviewed for this report. There were 1 male and 29 female patients whose ages ranged from 32 to 65 years (47.1±92 years). A total of 28 patients had atrial fibrillation and 2 patients were in sinus rhythm. There were 13 patients of mild TR, 10 patients of moderate TR and 7 patients of severe TR at the first mitral valve surgery. Five patients received the tricuspid annuloplasty of De Vega procedure at the same time, 2 patients received Kay procedure. The predominant presentation of patients included: abdominal discomfort (93.3%, 28/30), edema (66.7%,20/30), palpitation (56.7%, 17/30), and ascites (20%, 6/30). Results Nine patients underwent the secondary surgery for severe TR. The secondary surgery included tricuspid valve replacement (6 cases), mitral and tricuspid valve replacement (2 cases) and Kay procedure (1 case). Eight patients were recovered and discharged and 1 patient died from the bleeding of right atrial incision and low output syndrome. Twentyone patients received medical management and were followed up. One case was lost during followup. Conclusion Surgery or medical management should be based on the clinical characteristics of patients with severe TR after mitral valve surgery. It should be based on the features of tricuspid valve and the clinical experience of surgeon to perform tricuspid annuloplasty or replacement.

          Release date:2016-08-30 06:08 Export PDF Favorites Scan
        • Tricuspid Valve Replacement: Medium-and Long-term Results in 67 Cases

          Objective To analyze the medium-and long-term r esults of tricuspid valve replacement(TVR), to summarize the experience in opera tive therapy for tricuspid valve disease. Methods From January 1998 to May 2006, sixty seven patients had undergone TVR. The etiology was rheumatic disease in 25 cases, congenital disease in 37 cases, degenerative disease in 1 case, infective endocarditis in 3 cases, a nd cardiac tumor in 1 case. All operations were performed under general anesthes i a and by cardiopulmonary bypass. Bioprostheses was replaced in 28 patients, whil e mechanical valve was replaced in 39 patients. Associated procedure included mi tral valve replacement in 13 cases, mitral valve replacement and aortic valve replac ement in 12 cases, repair of ventricular septal defect in 1 case, repair of atri al septal defect in 1 case, and radioablation of atrial fibrillation in 3 case s. Results The operative mortality was 11.94% (8/67),among these patients , 6 cases died of serious heart failure,1 case died of ventricular fibrillation, 1 case died of multi organ failure. During follow-up, 1 patient died of biopro thesis dysfunction 1 year after the operation, 1 patient died of cerebral emboli s m 6 years after the operation. Through statistical analysis, it showed that the mortality of TVR in rheumatic tricuspid valve disease was higher than that in co ngenital tricuspid valve disease [5.56%(2/36)vs. 24.00% (6/25); χ2=4.425 , P=0.036]; the mortality in second time operation was higher than that in first time operation [30.00%(3/10)vs. 8.77% (5/57);χ2=3.646,P=0.033 ]; while there was no significant difference in immediate and long-term result s with different choice of bioprosthetic or mechanical valve in TVR (χ2=0.002 , P=0.961). Conclusion Operative an d follow-up mortality is high in the TVR, valve replac ement is the last selection for the treatment of serious tricuspid disease, appr opriate operative technique and perioperative therapy is the key for success o f the operation.

          Release date:2016-08-30 06:09 Export PDF Favorites Scan
        • DEVELOPMENT AND APPLICATION OF ARTIFICIAL VERTEBRAL BODY IN SPINAL SURGERY

          Objective To study the development, investigation, and application of the artificial vertebral body so as to provide an essential reference for the future research and clinical application. Methods The recent articles on materials, types, and clinical applications of the artificial vertebral body were reviewed.Results The materials used for the artificial vertebral body were porcelain, alloy, variant bone, and composite. But each of them had its own advantages and disadvantages. The types of the artificial vertebral body were grouped as expandable and non-expandable ones; however, the expandable type was much better. The artificial vertebral body had been applied to the treatments of spinal tumor, tuberculosis, fracture, and infection, with better effects. Conclusion The artificial vertebral body can beextensively applied. However, the materials and types need to be improved.

          Release date:2016-09-01 09:25 Export PDF Favorites Scan
        • Transcatheter aortic valve replacement in infective endocarditis with aneurysm of aortic sinus: a case report

          The patient underwent prostatectomy before two months. After the operation, he suffered from intermittent fever, chest tightness, and suffocation. Combined with the history, symptoms, signs, laboratory examination, echocardiography, imaging examination (CT), and the positive blood culture for Enterococcus faecalis, the admitting diagnosis was aortic stenosis and insufficiency, mitral insufficiency, cardiac function grade Ⅲ (New York Heart Association grade), infective endocarditis, and aneurysm of aortic sinus. After 4-week antimicrobial drug treatment, the patient was in a stable condition with normal body temperature, multiple negative blood cultures, and normal laboratory-related examinations. After careful and sufficient preparation, transcatheter aortic valve replacement operation was performed in the hybrid operating room with 32 mm Venus-A valve. The operation was successful and the patient was discharged on the seventh day after operation. He continued to be treated with antimicrobial drugs for 4 weeks after surgery, and his temperature was normal. He had no chest tightness, asthma, or other symptoms. One, three, and six months after operation, blood tests and erythrocyte sedimentation rate were normal, electrocardiogram showed sinus rhythm, and echocardiography showed a maximum aortic valve pressure difference of 7 mm Hg (1 mm Hg=0.133 kPa), no perivalvular leak and no pericardial effusion.

          Release date:2020-05-26 02:34 Export PDF Favorites Scan
        • Status and prospect of transcatheter valve-in-valve implantation for biological valve degeneration

          Along with the coming of aged society, the prevalence of heart valvular disease is significantly increasing, and the use of bioprosthetic valves for treating patients with severe valve disease has increased over the last two decades. As a consequence, a growing number of patients with surgical bioprosthesis degeneration is predicted in the near future. In this setting, valve-in-valve (ViV) transcatheter aortic/mitral valve replacement (TAVR/TMVR) has emerged as an alternative to redo surgery. A deep knowledge of the mechanism and features of the failed bioprosthetic heart valve is pivotal to plan an adequate procedure. Multimodal imaging is fundamental in the diagnostic and pre-procedural phases. The immediate and mid-term clinical and hemodynamic results have demonstrated the safety and feasibility of ViV techniques, but the development of these techniques faces several specific challenges, such as coronary obstruction, potential post-procedural mismatch and leaflet thrombosis. This article reviews the current status and prospects of ViV-TAVR technology in the treatment for biological valve degeneration, and suggests that ViV-TAVR should be promoted and implemented in existing medical centers with good surgical aortic valve replacement experience, so as to provide better treatment for patients.

          Release date: Export PDF Favorites Scan
        • Clinical research on radiofrequency ablation of atrial fibrillation with mitral valve replacement under totally thoracoscopic surgery

          ObjectiveTo investigate the feasibility, safety and effectiveness of radiofrequency ablation of atrial fibrillation with mitral valve replacement under totally thoracoscopic surgery.MethodsThe clinical data of 107 patients with rheumatic mitral disease and atrial fibrillation who underwent mitral valve replacement and radiofrequency ablation at the same time in our hospital from January 2014 to October 2018 were retrospectively analyzed. The patients were divided into two groups: a totally thoracoscopic surgery group (n=51, including 20 males and 31 females, aged 50.57±5.24 years) and a median sternotomy group (n=56, including 21 males and 35 females, aged 52.12±5.59 years) according to the surgical methods. The preoperative, intraoperative and postoperative data of the patients were compared.ResultsAll operations were successfully completed without death. In terms of bleeding volume, drainage volume, ventilator-assisted breathing time, hospital stay and incision length, the totally thoracoscopic surgery group was better than the median sternotomy group, and the difference was statistically significant (P<0.05). The cardiopulmonary bypass time and radiofrequency ablation time in the totally thoracoscopic surgery group were longer than those in the median sternotomy group (P<0.05). There was no significant difference in the operation time, aortic occlusion time, postoperative complications, left ventricular ejection fraction, left atrial diameter and sinus rhythm maintenance between the two groups (P>0.05). There was no atrioventricular block, pulmonary vein stenosis, atrioesophageal fistula, coronary artery injury, stroke or hemorrhage during the follow-up.ConclusionRadiofrequency ablation of atrial fibrillation with mitral valve replacement under totally thoracoscopic surgery is safe and effective, and it is worthy of clinical application.

          Release date:2020-07-30 02:32 Export PDF Favorites Scan
        53 pages Previous 1 2 3 ... 53 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜