• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Individualized" 20 results
        • Three-dimensional human-robot mechanics modeling for dual-arm nursing-care robot transfer based on individualized musculoskeletal multibody dynamics

          During transfer tasks, the dual-arm nursing-care robot require a human-robot mechanics model to determine the balance region to support the patient safely and stably. Previous studies utilized human-robot two-dimensional static equilibrium models, ignoring the human body volume and muscle torques, which decreased model accuracy and confined the robot ability to adjust the patient’s posture in three-dimensional spatial. Therefore, this study proposes a three-dimensional spatial mechanics modeling method based on individualized human musculoskeletal multibody dynamics. Firstly, based on the mechanical features of dual-arm support, this study constructed a foundational three-dimensional human-robot mechanics model including body posture, contact position and body force. With the computed tomography data from subjects, a three-dimensional femur-pelvis-sacrum model was reconstructed, and the individualized musculoskeletal dynamics was analyzed using the ergonomics software, which derived the human joint forces and completed the mechanic model. Then, this study established a dual-arm robot transfer platform to conduct subject transfer experiments, showing that the constructed mechanics model possessed higher accuracy than previous methods. In summary, this study provides a three-dimensional human-robot mechanics model adapting to individual transfers, which has potential application in various scenarios such as nursing-care and rehabilitating robots.

          Release date:2025-02-21 03:20 Export PDF Favorites Scan
        • VALIDATION STUDY ON PRECISION OF DIGITIZED CUSTOM-MADE RADIAL HEAD PROSTHESIS BY THREE-DIMENSIONAL VISUALIZATION OF VIRTUAL SURGERY

          Objective To study digitize design of custom-made radial head prosthesis and to verify its matching precision by the surgery of preoperative three-dimensional (3-D) virtual replacement. Methods Six healthy adult volunteers (3 males and 3 females, aged 25-55 years with an average of 33 years) received slice scan of bilateral elbow by Speed Light 16-slice spiral CT. The CT Dicom data were imported into Mimics 10.0 software individually for 3-D reconstruction image, and the left proximal radial 3-D image was extracted, the mirror of the image was generated and it was split into 2 pieces: the head and the neck. The internal diameter and the length of the radial neck were obtained by Mimics 10.0 software measurement tools. In Geomagic Studio 12 software, the radial head was simulated to cover the cartilage surface (1 mm thickness) and generated to an entity. In UG NX 8.0 software, the stem of prosthesis was designed according to the parameters above and assembled head entity. Each custom-made prosthesis was performed and verified its matching precision by the surgery of preoperative 3-D virtual replacement. Results Comparing the morphology of 6 digitize custom-made prostheses with ipsilateral radial heads by the 3-D virtual surgery, the error was less than 1 mm. The radial head prosthesis design on basis of the contralateral anatomy was verified excellent matching. Conclusion The 3-D virtual surgery test and the digitized custom-made radial head prosthesis will be available for clinical accurate replacement.

          Release date:2016-08-31 04:12 Export PDF Favorites Scan
        • Multiple Minimally Invasive Therapy and Individualized Treatments Combination for Patients with Severe Acute Pancreatitis

          Objective To evaluate the efficacy of multiple minimally invasive therapy and individualized treatments combination in severe acute pancreatitis. Methods The data of sixty-seven patients with severe acute pancreatitis between September 1998 and October 2008 undergoing multiple minimally invasive therapy and individualized treatments were analyzed retrospectively. The changes of APACHE Ⅱ score, CT score, WBC count, total bilirubin, AST, blood glucose, amylase, lypase, C-reactive protein, tumor necrosis factor-α, blood urea nitrogen, creatinine, and oxygenation index (PaO2/FiO2) were observed and compared between before and after treatment. Time of abdominal pain relieved, laparotomy rate, mortality rate, recovery rate, hospital stay, and cost of hospitalization were also observed. Results All the detected indexes improved significantly after treatments compared with those before treatments (Plt;0.001). Time of abdominal pain relieved was (20.17±14.16) h. Laparotomy rate was 6.0% (4/67). Mortality rate was 7.5% (5/67). Recovery rate was 92.5% (62/67). Hospital stay was (30.85±28.37) d and cost of hospitalization was (59 295.78±34 564.44) yuan. Conclusions Multiple minimally invasive therapy and individualized treatments for cases of severe acute pancreatitis with different causes, course, severity of disease, and complications, could significantly improve the clinical indexes and recovery rate of severe acute pancreatitis.

          Release date:2016-09-08 10:54 Export PDF Favorites Scan
        • Death Caused by Degree-Ⅳ Myelosuppression after Oral Tegafur, Gimeracil and Oteracil Potassium Capsule: a Report of One Case and the Literature Review

          ObjectiveTo suggest the importance of taking notice of oral chemotherapy drugs in cancer patients, and the importance of drug-use evaluation in patients with insufficient kidney functions, by reporting one death case caused by multiple organ failure because of myelosuppression after oral tegafur, gimeracil and oteracil potassium (S-1) capsules for 10 days in a patient with insufficient kidney functions. MethodsThrough the analysis of one patient who died of multiple organ failure due to degree-Ⅳ myelosuppression and the related literature review, we discussed the necessity of individualized administration of clinical chemotherapy. ResultsThe patient had grade-Ⅱ renal insufficiency before chemotherapy and did not undergo dihydropyrimidine dehydrogenase (DPYD) gene test. Myelosuppression occurred 10 days after oral chemotherapy drugs. The white blood cells, neutrophils and platelets decreased progressively, and then developed into degree-Ⅳ suppression. Finally the patient died of multiple organ failure. Conclusions Genetic variation and renal insufficiency may cause differences in drug metabolism. The reduced urinary excretion of guimet pyrimidine (CDHP), the inhibitors of dihydropyrimidine dehydrogenase which is the 5-fluorouracil (5-FU) metabolic enzyme, may lead to elevated plasma concentration of 5-FU, thereby increasing myelosuppression and other adverse reactions. If DPYD gene detection results show low enzyme activity, it can cause lethal toxicity through deceleration of 5-FU metabolism and high concentration of blood. DPYD gene dzetection should be performed if allowed, and individualized treatment plan should be formulated after comprehensive evaluation. The overall situation of the patients should be considered before treatment, and then individualized drugs should be administered.

          Release date:2016-10-28 02:02 Export PDF Favorites Scan
        • Relation between the length of navigation pipe and accuracy of screw placement in cervical pedicle screw placement assisted by 3D printed navigation template

          Objective To evaluate the deviation between actual and simulated screw placement after cervical pedicle screw placement assisted by 3D printed navigation template, and analyze the correlation between screw placement deviation and navigation pipe length. Methods A total of 40 patients undergoing cervical 1-7 pedicle screw insertion assisted by 3D printed navigation template in Zigong Fourth People’s Hospital between February 2018 and August 2020 were included in this prospective study. These patients were divided into 3 groups randomly, including 12 patients with a 5-mm pipe length (5 mm group), 13 patients with a 10-mm pipe length (10 mm group), and 15 patients with a 15-mm pipe length (15 mm group). Three-dimensional modeling was performed on preoperative cervical CT images of these patients and simulated pedicle screw was placed. Individualized pedicle screw navigation templates were designed according to the position and direction of simulated pedicle screws, and 3D printing was performed on the cervical model and navigation templates. Preoperative 3D printed model and navigation templates were used to simulate the surgical process to confirm the safety of screws. During the operation, pedicle screw placement was performed according to the preoperative design and simulated surgical process. The postoperative CT images were registered with the preoperative CT images in 3D model. The safety of screw placement was evaluated by the postoperative screw placement Grade, and the accuracy of screw placement was evaluated by measuring the deviation of screw placement point and the deviation of screw placement direction in horizontal plane (inclination angle) and sagittal plane (head inclination angle). The influence of different navigation pipe lengths on the safety and accuracy of screw placement was analyzed. Results A total of 164 pedicle screws were inserted with navigation template assistance, including 48 screws (38 in Grade 0 and 10 in Grade 1) in the 5 mm group, 52 screws in the 10 mm group (all in Grade 0), and 64 screws (52 in Grade 0 and 12 in Grade 1) in the 15 mm group, and the difference in the grade among the three groups was statistically significant (P<0.05). When the navigation pipe length was 5, 10, and 15 mm, respectively, the screw entry point deviation was (1.87±0.63), (1.44±0.63), and (1.66±0.54) mm, respectively, the inclination angle deviation was (2.72±0.25), (0.90±0.21), and (1.84±0.35)°, respectively, and the head inclination angle deviation was (8.63±1.83), (7.15±1.38), and (8.24±1.52)°, respectively. The deviations in the 10 mm group were all significantly less than those in the other two groups (P<0.05). Conclusions In the cervical pedicle screw placement assisted by navigation template, all the screws were Grade 0 or Grade 1, with high safety. The mean deviation of the screw entry point is within 2 mm, with high accuracy. When the length of navigation pipe is 10 mm, the safety and accuracy of screw placement can be fully guaranteed.

          Release date:2021-11-25 03:04 Export PDF Favorites Scan
        • Individualized Assessment Method of Evidence-Based Goal Attainment Scale Produced in TCM

          To aim directly at the individualized character and tendency about clinical assessment of Traditional Chinese Medicine (TCM), we draw off a new pathway which is evidence-based goal attainment scale(EBGAS) in the text. i.e., we will develop clinical individualized assessment method of TCM on account of GAS by the approach of evidence based medicine.

          Release date:2016-09-07 02:16 Export PDF Favorites Scan
        • Individualized surgical management of secondary rhinoplasty for cleft lip

          ObjectiveTo explore the effectiveness of transplantation of engraved autologous costal cartilage for individualized surgical management in secondary rhinoplasty for cleft lip. MethodsBetween September 2009 and January 2014, 350 patients with secondary nasal deformity of cleft lip were treated, including 160 males and 190 females with a mean age of 18.2 years (range, 16-56 years). Nasal deformity was caused by unilateral cleft lip in 200 cases and by bilateral cleft lip in 150 cases. The interval of lip repair and nasal deformity correction was 2-50 years (mean, 12 years). About a 2-6 cm cartilage was harvested from the 6th or 7th costal cartilage, and was engraved to the shape of "ge" in Chinese. The upper part was strengthened on both sides of the alar cartilage; the lower part was fastened to columella and nasal septum cartilages. The rest of cartilages was diced into 0.1 mm×0.1 mm×0.1 mm cubes. The columella incision was designed to "Z"-plasty, and was stretched to the nasion along alar edge. The engraved autologous costal cartilage was transplanted and fixed to the collapse of nostril. The cartilage cube was transplanted and filled into the collapse of nasal root to achieve the aesthetic effect of nasal augmentation. The effectiveness was evaluated according to the grade of secondary rhinoplasty for cleft lip by ZHANG Li et al. at 1, 6, and 12 months after operation. ResultsAll incisions were primary healing. All patients were followed up 1-12 months (mean, 6 months). After rhinoplasty, the collapse of nostrils was lifted, and the shape and height of collapse of nostrils were symmetrical to normal side. The deflection of columella nasi was corrected. A beautiful shape of nose was achieved. The excellent and good rates were 98.6% at 1 month, 97.4% at 6 months, and 97.1% at 12 months after operation, showing no significant difference (χ2=0.545, P=0.761). ConclusionThe technique of transplantation of engraved autologous costal cartilage for individualized surgical management in secondary rhinoplasty for cleft lip can achieve excellent surgery effect.

          Release date: Export PDF Favorites Scan
        • Application of individualized transiliac crest nail-grafting guide plate in deep pelvic external fixator implantation

          Objective To explore the application of individualized transiliac crest nail-grafting guide plate prepared by computer-aided design and three-dimensional (3D) printing technology in deep pelvic external fixator implantation. Methods Five patients with pelvic fractures were collected between May 2017 and February 2018. There were 4 females and 1 male with an average age of 52 years (range, 29-68 years). Pelvic fractures were classified as type B in 3 cases and type C in 2 cases by Tile classification. The interval between injury and operation was 6-14 days (mean, 9 days). The preoperative CT images of pelvic fractures were collected. The data was reconstructed by 3D imaging reconstruction workstation. An individualized transiliac crest nail-grafting guide plate was designed on the virtual 3D model. The individualized transiliac crest nail-grafting guide plate and the solid pelvic model were produced with the 3D printing technology. The individualized transiliac crest nail-grafting guide plate was used for intraoperative deep pin position on iliac crest after the preoperative simulation. The follow-up CT scans were used to determine the differences in distance from anterior superior iliac spine, convergence angle, and caudal angle between the preoperative plan and postoperative measurement. Results During the operation, the individualized transiliac crest nail-grafting guide plate was used to guide the placement of 20 pins. X-ray film and CT examination showed that all pins were well positioned. The average depth of pins was 83.16 mm (range, 70.13-100.53 mm). Fitted 3D reconstruction images showed that the entry point and orientation of the pins were all consistent with preoperative schemes. Compared with the planned nail path, there was no significant difference in the distance from anterior superior iliac spine, convergence angle, and caudal angle in the actual nail path (P>0.05). No loosening and rupture of pin, no damage of blood vessels and nerve, and shallow or deep infection occurred during 3 months follow-up, and the incisions healed by first intention. All patients were satisfied with the treatment process. The ranges of motion of hip and knee were normal, and the visual analogue scale (VAS) score was 0-3 (mean, 0.5). Conclusion The individualized transiliac crest nail-grafting guide plate technique is the improvement of traditional technique. It can increase accuracy and effective depth of pin position, enable patients to obtain pelvic mechanical stability quickly after operation, and reduce the risk of complications related to nail path.

          Release date:2019-08-23 01:54 Export PDF Favorites Scan
        • Progress in CT-guided implantation of iodine-125 seeds for malignant tumors assisted by individualized 3D template

          The iodine-125 (125I) seeds interstitial implantation has the advantages of minimal invasiveness, high local control rate, and few complications; it has attracted worldwide attention. With the application of 3D printing technology in medicine, individualized 3D templates are gradually applied to clinical practice. Individualized 3D templates combining with CT-guided 125I seeds implantation are easy to operate and can not only effectively ensure the consistency and accuracy of preoperative and postoperative dose, but also minimize complications to achieve optimal efficacy. This paper reviews the application of CT-guided implantation of 125I seeds for malignant tumors assisted by individualized 3D template, and further demonstrates the safety and effectiveness of clinical application in 125I seeds implantation to provide a reliable basis for the standardization of 125I seeds implantation.

          Release date:2019-08-15 01:20 Export PDF Favorites Scan
        • COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS

          ObjectiveTo study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. MethodsOne adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. ResultsAccording to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. ConclusionCustomized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

          Release date: Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜