• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Digit" 59 results
        • Accuracy of computer-guided oral implant placement and influencing factors

          With the development of computer and digital technology, the application of computer-aided technology has become a new trend in the field of oral implant. Computer-guided oral implant surgery has the advantages of being safer and more accurate than traditional implant surgery, and it can truly realize the concept of restoration-oriented implant. However, computer-guided oral implant surgery has various steps which cause deviations accumulation, so that some clinicians remain sceptical about the accuracy of the technology. Currently, due to the lack of a quantitative system for evaluating the accuracy of computer-guided oral implantation, the implant deviation in each step is still inconclusively in the stage of research and debate. The purpose of this paper is to summarize the advantages and disadvantages, research progress, accuracy and influencing factors of computer-guided oral implantation, aiming to provide a reference for improving implant accuracy and guiding clinical design and surgery.

          Release date:2022-10-25 01:09 Export PDF Favorites Scan
        • Advances in application of digital orthopedic technology in total hip arthroplasty for developmental dysplasia of hip

          Objective To review the research progress on the application of digital orthopedic technology in total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH), thereby providing a reference for clinical decision-making. MethodsA comprehensive literature review was conducted to summarize the effectiveness of various emerging digital orthopedic technologies in the context of THA for DDH. Results Digital orthopedic technologies have significantly enhanced the precision and safety of THA for DDH. Specifically, artificial intelligence-based preoperative planning systems have demonstrated superior accuracy in prosthesis size matching and positioning compared to conventional methods. Additive manufacturing technologies have provided personalized solutions for reconstructing complex bone defects in DDH. Furthermore, robot-assisted and navigation-assisted techniques have effectively improved the accuracy of prosthesis placement and lower limb length restoration in THA. However, each of these digital orthopedic technologies still possesses its own limitations. ConclusionThrough the integration of multiple technologies, digital orthopedics effectively addresses the challenges of precise reconstruction in THA for DDH. Future efforts should focus on further integrating diverse intelligent technologies and equipment to establish a comprehensive digital diagnosis and treatment system, aiming to achieve superior long-term effectiveness.

          Release date:2026-01-08 04:33 Export PDF Favorites Scan
        • TRANSPLANTATION OF THE PALMARIS LONGUS TENDON WITH A VASCULAR PEDICLE FOR THE COMPLEX INJURY OF THE DIGITAL FLEXOR TENDON

          In order to seek a good method to treat the severe, complex damage of the digital flexor tendon, an anatomical study based on 30 cadavers was done, and the result showed that the source of the blood supply to the palmaris longus tendon was from the radial and ulnar arteries. Three cases of severe complex digital flexor tendon injuries were satisfactory. Its main advantages were: (1) The tendon transplant had its own blood supply and had no need to the revascularization, therefore the adhesion formed between the tendon and adjacent tisues might be less;(2) Besides reparing the tendon defect, it can simultaneously solve the problem of the defect of the soft tissues and the skin.

          Release date:2016-09-01 11:33 Export PDF Favorites Scan
        • Single-Injection Digital Block versus Traditional Digital Block for Local Anesthesia in Digital Injury Patients: A Randomized Controlled Trial

          Objective To compare the anesthetic effects of traditional digital block with single-injection digital block in digital injury patients for subcutaneous digital blocks. Methods Patients with one or two digits injured were randomized to the traditional digital block group and single-injection digital block group. All of the blocks were conducted by one investigator. The patients and outcome assessor were blinded to the treatment allocation. Both of the per-protocol-population (PP) analysis and the intention-to-treatment (ITT) analysis were performed to compare the two block techniques in terms of the pain during infiltration, the onset time of anesthesia and the failure rate of anesthesia. Results A total of 93 patients (109 digits) were included with 51 (61 digits) in the traditional block group and 42 (48 digits) in the single-injection block group.Two patients (3 digits) dropped out. Both of the PP analysis and ITT analysis showed that no significant difference between the two groups were detected in terms of the pain during infiltration, the onset time of anesthesia and the failure rate of anesthesia (P﹥0.05). Conclusions The subcutaneous single-injection digital block is as effective as the traditional digital block, but is much easier to perform. This technique is indicated for the digital anesthesia of palmar aspect distal to the proximal digital crease and dorsal aspect of the distal and middle phalanxes.

          Release date:2016-09-07 02:18 Export PDF Favorites Scan
        • CLINICAL APPLICATION OF VASCULARIZED SKIN FLAP WITH NERVE (REPORT OF 10 CASES)

          The digital defects which severely interfered with the hand functions must be reconstructed. The primary repair by vascularized skin flap with the dorsal branch of proper palmar digital nerve could be done. The vascularized flap was rich in blood circulation, perfect sensibility and a good contour, as well as preserving donor digital sensation. However, it was simple, safe, and with higher success. From 1989 to 1991, 10 cases of digital defects were treated, all of the patients gained very good results. The indication and technique of thismethod wasdiscussed in detail.

          Release date:2016-09-01 11:38 Export PDF Favorites Scan
        • Multidetector-Row CT Angiography and Digital Subtraction Angiography of Bronchial Artery in Diagnosis of Hemoptysis: A Comparative Study

          Objective To compare the bronchial arteriography through multidetector-row CT (MDCT) with the digital subtraction angiography (DSA) via femoral artery, and evaluate the application value of bronchial arteriography through MDCT in the diagnosis and treatment of hemoptysis. Methods 133 cases complained of hemoptysis were examined by MDCT and DSA via femoral artery respectively to perform bronchial arteriography, and the differences of image results by two methods were compared. Results 129 cases with abnormal bronchial arteries were confirmed by DSA via femoral artery, 117 cases were checked by MDCT [ the positive rate was 90.7% (117/129 ) ] . 117 cases with abnormal bronchial arteries were confirmed by both MDCT and DSA via femoral artery and 4 cases did not detected any abnormal arteries by both methods. The coincidence rate of two methods was 91.0% (121 /133) . MDCT and DSA via femoral artery showed the similar origins of abnormal bronchial arteries. The coincidence rate of two methods was 100% . Conclusions There is a high coincidence rate betweenMDCT and DSA in detecting bronchial artery abnormalities. MDCT shows the origins of abnormal vessels clearly which could be a fist-choice of routine imagination for interventive operation.

          Release date: Export PDF Favorites Scan
        • Application of mixed reality technology in orthopedic field

          Mixed reality technology is new digital holographic imaging technology that generates three-dimensional simulation images through computers and anchors the virtual images to the real world. Compared with traditional imaging diagnosis and treatment methods, mixed reality technology is more conducive to the advantages of precision medicine, helps to promote the development of medical clinical application, teaching and scientific research in the field of orthopedics, and will further promote the progress of clinical orthopedics toward standardization, digitization and precision. This article briefly introduces the mixed reality technology, reviews its application in the perioperative period, teaching and diagnosis and treatment standardization and dataization in the field of orthopedics, and discusses its technical advantages, aiming to provide a reference for the better use of mixed reality technology in orthopedics.

          Release date:2021-09-24 01:23 Export PDF Favorites Scan
        • APPLICATION OF V-Y ADVANCEMENT FLAP PEDICLED WITH DORSAL CUTANEOUS BRANCH OF DIGITAL ARTERY FOR SKIN DEFECT AT THE SAME DORSAL FINGER

          Objective To investigate the therapeutic effect of V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery for skin defect at the same dorsal finger. Methods Between January 2008 and February 2010, 15 cases of skin defect at the same dorsal finger were treated. There were 9 males and 6 females, aged 15-72 years (mean, 43 years). Defect was caused by saw machine in 6 cases, machines crush in 7 cases, and cutting nodule in 2 cases. The locationswere distal dorsal finger in 2 cases, middle dorsal finger in 6 cases, and proximal dorsal finger in 7 cases. All cases compl icated by exposure of tendon and bone. The size of defect ranged from 0.8 cm × 0.5 cm to 1.4 cm × 1.0 cm. The interval between injury and operation was 3-8 hours. All fingers were treated by V-Y advancement flap from the dorsal cutaneous branch of digital artery, which size was 1.2 cm × 0.8 cm-2.5 cm × 1.0 cm, and the donor site was directly sutured. Fracture reductionand Kirschner wire for internal fixation were performed in the patients with fracture; extensor tendon was repaired with 4-0 thread in the patients with tendon injury. Results All flaps survived completely. The incisions of donor and recipient sites healed by first intention. Ten cases were followed up 6 months to 2 years after operation. The flaps had good texture, color, and appearance; 2-point discrimination of the V-Y flap was 10-12 mm. X-ray examination showed that all finger fractures healedsuccessfully in 5 cases, with an average bone union time of 6 weeks (range, 5-8 weeks). According to the criteria for function assessment by total active motion, the results were excellent in 8 cases, good in 1, and fair in 1 with an excellent and good rate of 90%. Conclusion It is an ideal method to treat skin defect at the same dorsal finger with V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery.

          Release date:2016-08-31 05:41 Export PDF Favorites Scan
        • Risk Factors for Carotid Stenosis in Patients with Ischemic Cerebrovascular Disease

          ObjectiveTo analysis the risk factors for carotid stenosis in patients with ischemic cerebrovascular disease based on digital subtraction angiography. MethodsA total of 312 patients diagnosed with ischemic cerebrovascular disease who underwent digital subtraction angiography from June 2011 to September 2013 were selected.The risk factors of carotid stenosis were analysised by multivariate logistic regression analysis. ResultsIn 312 patients,271 were with cerebral infarction and 41 were transient ischemic attack patients.There were 149 patients in carotid stenosis group (stenosis degree ≥50%) and 163 patients in control group (stenosis degree<50%).The age (OR=1.037,P=0.000) and coronary heart disease (OR=4.121,P=0.001) were independent risk factors of carotid stenosis with ischemic cerebrovascular disease. ConclusionCarotid stenosis is common in ischemic cerebrovascular disease.Age and coronary heart disease were the independent risk factors.The recognition and control of these risk factors are in favor of secondary prevention of ischemic cerebrovascular disease.

          Release date: Export PDF Favorites Scan
        • VALIDATION STUDY ON PRECISION OF DIGITIZED CUSTOM-MADE RADIAL HEAD PROSTHESIS BY THREE-DIMENSIONAL VISUALIZATION OF VIRTUAL SURGERY

          Objective To study digitize design of custom-made radial head prosthesis and to verify its matching precision by the surgery of preoperative three-dimensional (3-D) virtual replacement. Methods Six healthy adult volunteers (3 males and 3 females, aged 25-55 years with an average of 33 years) received slice scan of bilateral elbow by Speed Light 16-slice spiral CT. The CT Dicom data were imported into Mimics 10.0 software individually for 3-D reconstruction image, and the left proximal radial 3-D image was extracted, the mirror of the image was generated and it was split into 2 pieces: the head and the neck. The internal diameter and the length of the radial neck were obtained by Mimics 10.0 software measurement tools. In Geomagic Studio 12 software, the radial head was simulated to cover the cartilage surface (1 mm thickness) and generated to an entity. In UG NX 8.0 software, the stem of prosthesis was designed according to the parameters above and assembled head entity. Each custom-made prosthesis was performed and verified its matching precision by the surgery of preoperative 3-D virtual replacement. Results Comparing the morphology of 6 digitize custom-made prostheses with ipsilateral radial heads by the 3-D virtual surgery, the error was less than 1 mm. The radial head prosthesis design on basis of the contralateral anatomy was verified excellent matching. Conclusion The 3-D virtual surgery test and the digitized custom-made radial head prosthesis will be available for clinical accurate replacement.

          Release date:2016-08-31 04:12 Export PDF Favorites Scan
        6 pages Previous 1 2 3 ... 6 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜