• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Author
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Author "范雪" 3 results
        • Clinical Analysis of 160 Cases of Initial Continuous Positive Airway Pressure in Premature Infants

          ObjectiveTo analyze the application and efficacy of continuous positive airway pressure (CPAP) as an initial support measure for respiratory diseases in premature infants. MethodsWe retrospectively studied the clinical data of 160 premature infants hospitalized in the Neonatal Intensive Care Unit from January to December 2014. These infants accepted CPAP as the initial respiratory support. ResultsThe average birth weight and the average gestational age of the 160 premature infants were (1 581±440) g and (31.6±1.9) weeks, respectively. The main diagnosis of the primary diseases in these infants included neonatal pneumonia (81.3%), neonatal respiratory distress syndrome (57.5%), neonatal apnea (53.8%) and neonatal asphyxia (22.5%). The CPAP success rate in those infants whose birth weight was less than 1 000 g was significantly lower than those whose birth weight was equal or greater than 1 000 g (χ2=4.882, P=0.027). The perinatal period analysis showed that premature rupture of membranes, intrauterine fetal distress and maternal pregnancy complications were factors correlating with the effect of CPAP. CPAP treatment analysis showed that early application of CPAP within 24 hours after birth had a success rate of 82.4% (108/131), and initial inhaled oxygen concentration and oxygen pressure were the primary factors affecting CPAP efficacy. ConclusionApplication of CPAP is effective in respiratory support for premature infants and has a high success rate. Early application can reduce the use of mechanical ventilation and intubation. Regulating appropriate parameters helps raise the efficacy of CPAP therapy. Clinically, the standardized application of CPAP and monitoring the failure of CPAP are important for the improvement of the treatment efficacy.

          Release date:2016-11-23 05:46 Export PDF Favorites Scan
        • 早產兒初始持續氣道正壓通氣失敗的危險因素分析

          目的 分析早產兒初始持續氣道正壓通氣(continuous positive airway pressure,CPAP)失敗的相關危險因素,為早產兒選擇有效的呼吸支持方式提供臨床依據。 方法 選取 2014 年 1 月—12 月在新生兒科住院初始呼吸支持為 CPAP 的早產兒 152 例,對其臨床資料進行回顧性研究,分析 CPAP 失敗的相關危險因素。 結果 單因素分析顯示出生體質量、胎膜早破、臍帶異常、宮內窘迫、生后窒息、孕母妊娠期高血壓、孕母妊娠期糖尿病、產前使用激素、使用 CPAP 時日齡、初始吸入氧濃度、初始氧分壓這 11 項因素與 CPAP 失敗的關聯有統計學意義;logistic 回歸分析表明低出生體質量、宮內窘迫、使用 CPAP 較晚是影響 CPAP 失敗的主要危險因素。 結論 綜合分析出生體質量、宮內窘迫、使用 CPAP 日齡等圍生期因素是 CPAP 失敗的主要預測因素。

          Release date:2017-04-19 10:17 Export PDF Favorites Scan
        • Constructing an intelligent ultrasound diagnosis system for breast nodules in patients with abnormal thyroid function using deep learning algorithms

          ObjectiveTo construct an intelligent ultrasound diagnosis system for breast nodules in patients with thyroid dysfunction using deep learning algorithms. MethodsA retrospective analysis was collected breast ultrasound images of 178 patients with thyroid dysfunction from the ultrasound database of the First Affiliated Hospital of Xinjiang Medical University from January 2023 to February 2024, which served as the training set. The deep learning algorithm was used to construct an intelligent ultrasound diagnosis system for breast nodules in patients with thyroid dysfunction. In addition, a retrospective analysis was collected breast ultrasound images of 81 patients with thyroid dysfunction from the ultrasound database of the First Affiliated Hospital of Xinjiang Medical University from March 2024 to January 2025, which served as the validation set. The above system was used as validation set to diagnose whether patients with thyroid dysfunction had breast nodules, and the diagnostic efficacy of imaging physicians’ diagnosis and the intelligent ultrasound diagnosis system for breast nodules in patients with thyroid dysfunction was analyzed. The consistency between the diagnosis of ultrasound physicians, intelligent ultrasound diagnosis system and the “gold standard” was tested by Kappa test. ResultsThere was no statistically significant difference in age, type of thyroid dysfunction, disease duration, number of breast nodules, and other clinical data between the training set and the validation set (P>0.05). The time required for the training set intelligent ultrasound diagnostic system to diagnose a single breast ultrasound image was (0.04±0.01) min, which was lower than that of an ultrasound specialist [(12.36±2.58) min], t=63.709, P<0.001. The sensitivity, specificity, accuracy, and area under the curve (AUC) of detecting breast nodules in patients with thyroid dysfunction using an intelligent ultrasound diagnostic system were 97.87% (46/47), 100% (34/34), 98.77% (80/81), and 0.997 [95%CI: (0.951, 1.00)], respectively. The sensitivity, specificity, accuracy, and AUC of detecting breast nodules by ultrasound physicians were 89.36% (42/47), 91.18% (31/34), 90.12% (73/81), and 0.904 [95%CI: (0.818, 0.958)], respectively. The AUC of the intelligent ultrasound diagnosis system was higher than that of the ultrasound physician (Z=2.673, P=0.008). The detection results of breast nodules in patients with thyroid dysfunction diagnosed by ultrasound physicians were generally consistent with the “gold standard” (Kappa value=0.799, P<0.001), while the intelligent ultrasound diagnosis system was in good agreement with the “gold standard” (Kappa value=0.975, P<0.001). The confusion matrix results showed that the number of false positives was 3 and 0 for the ultrasound department physicians and the intelligent ultrasound diagnostic system, respectively, while the number of false negatives was 5 and 1. The calibration curve results indicated a high consistency between the diagnostic probability and the actual probability of the intelligent ultrasound diagnostic system, with the calibration curve fitting well with the ideal curve (Hosmer-Lemeshow test: χ2=1.246, P=0.997). ConclusionThe intelligent ultrasound diagnosis system for breast nodules in patients with thyroid dysfunction constructed by deep learning algorithm has good diagnostic efficacy, which can help ultrasound physicians improve screening efficiency and accuracy.

          Release date: Export PDF Favorites Scan
        1 pages Previous 1 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜