Objective To investigate an effect of the minimally-invasive locking compression plate (LCP) under the anterior humeral approach to treat the complex humeral shaft fracture. MethodsEleven patients (6 males, 5 females; age, 3266 years) with a humeral shaft fracture were treated with the minimally-invasive LCP under the modified anterior humeral approach from March 2005 to February 2006. Five of the patients were injured in a traffic accident and the remaining 6 were wounded in a fall. All the patients had an unstable fracture. The multiple segment fracture was found in 2 patients, the obligue line fracture in 1 patient, and the long segment comminuted fracture in 8 patients, of whom the radial nerve injury was found in 1 patient, who had an emergency treatment by the loosening of the radial nerve and the internally fixing with LCP. As for the fracture site, the middle and/or the upper-part fracture of the humerus was found in6 patients, and the middle and/or lower-part fracture of the humerus was foundin 5 patients. The patients underwent the operation in the period from 48 hours to 4 days after the injuries. Results All the patients had a complete healing of their fractures 2-4 months after operation. One patient underwent the loosening of the radial nerve and the internally-fixing with LCP, and his function recovered 3 days after operation.The follow-up for 6-12 months revealed that all the patients’ function recovered. According to the Neer Scoring System for the shoulder function evaluation, 7 patients had an excellent result, 3 had a good result, and 1 had a fair result. According to the HSS Scoring System, 9 patients had an excellent result and 2 had a good result. Conclusion The minimally-invasive locking compression plate under the anterior humeral approach to treat the complex humeral shaft fracture is an effective and safe method of treating the complex humeral shaft fracture.
Objective To compare the effectiveness between locking compression plate (LCP) and locked intramedullary nail (IMN) for humeral shaft fractures of types B and C. Methods Between January 2010 and January 2012, 46 patients with humeral shaft fractures of types B and C were treated, and the clinical data were retrospectively analyzed. LCP was used for internal fixation in 22 cases (LCP group), and IMN in 24 cases (IMN group). There was no significant difference in gender, age, injury causes, the side of fracture, the site of fracture, the type of fracture, associated injury, and time from injury to operation between 2 groups (P gt; 0.05). The regular clinical examination and evaluation of radiography were done. Shoulder function was evaluated by Neer grading system and elbow function was evaluated by Mayo elbow performance score after operation. Results The operation time and intraoperative blood loss in IMN group were significantly lower than those in LCP group (P lt; 0.05). There was no significant difference in hospitalization time between 2 groups (t=0.344, P=0.733). All patients were followed up 16.8 months on average (range, 12-24 months). At 6 months after operation, bone nonunion occurred in 1 patient of LCP group and in 2 patients of IMN group; the bone healing rate was 95.5% (21/22) in LCP group and 91.7% (22/24) in IMN group, showing no significant difference (χ2=0.000, P=1.000). Except for nonunion patients, the bone healing time was (11.77 ± 0.75) weeks in LCP group and (11.38 ± 0.82) weeks in IMN group, showing no significant difference (t=1.705, P=0.095). Between LCP and IMN groups, significant differences were found in radial nerve injury (4 cases vs. 0 case) and impingement of shoulder (0 case vs. 6 cases) (P lt; 0.05), but no significant difference in superficial infection (1 case vs. 0 case) and iatrogenic fracture (1 case vs. 2 cases) (P gt; 0.05). There was no significant difference in shoulder function and elbow function at 1 year after operation between 2 groups (P gt; 0.05). Conclusion LCP fixation and IMN fixation for humeral shaft fractures of types B and C can achieved satisfactory results. More attention should be paid to avoiding radial nerve injury by fixation of LCP; nail tail should be buried deeply into the cortex of the greater tuberosity and rotator cuff should be protected to decrease the rate of impingement of shoulder by fixation of IMN.
To provide the scientific theoretical basis for cl inical practice by comparing biomechanicalcharacteristics of single compressed plate with intramedullary pin, locking intramedullary nail and simple arm externalfixator with simple internal fixation devices. Methods Eighteen wet humeral bone specimens of adult cadaver were madecompl icated fracture models of humeral shaft and divided into 3 groups according to fixation methods. Fracture was fixed by single compressed plate with intramedullary pin in plate group, by locking intramedullary nail in intramedullary nail group and by external fixator with simple internal fixation devices in external fixator group. The intensity and rigidity of compl icated fracture models of humeral shaft was measured in compress test and torsion test. Results In compress test, the maximum load in plate group (6 162.09 ± 521.06) N and in intramedullary nail group (6 738.32 ± 525.89) N was significantly larger than that in external fixator group (2 753.57 ± 185.59) N (P lt; 0.05); but there was no significant difference between plate group and intramedullary nail group (P gt; 0.05). Under 600 N physiological compress load, the rigidity was (171.69 ± 6.49) N/mm in plate group, (333.04 ± 36.85) N/mm in intramedullary nail group and (132.59 ± 2.93) N/mm in external fixator group; showing no significant difference between plate group and external fixator group (P gt; 0.05), and showing significant difference between intramedullary nail group and plate, external fixator groups (P lt; 0.05). In torsion test, the maximum torque in plate group (38.24 ± 7.08) Nm was significantly larger than those in intramedullary nail group (17.12 ± 5.73) Nm and external fixator group (20.26 ± 6.42) Nm (P lt; 0.05), but there was no significant difference between intramedullary nail group and external fixator group (P gt; 0.05). Under 0.80 Nm physiological torque, the rigidity was (16.36 ± 2.07) Ncm/° in plate group and (18.79 ± 2.62) Ncm/° in external fixator group, which was significantly larger than that in intramedullary nail group (11.45 ± 0.22) Ncm/° (P lt; 0.05); but there was no significant difference between plate group and external fixator group (P gt; 0.05). Conclusion Those fracture models fixed by single compressed plate with intramedullary pin have better compress and torsion intensity, they also have better torsion rigidity but less compress rigidity. Those fracture models fixed by locking intramedullary nail have better compress intensity but less torsion intensity, they also have better compress rigidity but less torsion rigidity. Those fracture models fixed by external fixator with simple internal fixation device have less compress and torsion intensity, they also have less compress rigidity but better torsion rigidity.
To explore the possibil ity of treating mid-distal humeral shaft fractures associated with radial nerve palsies with minimal invasive plating osteosynthesis (MIPO) techniques. Methods From April 2003 to October 2006, 10 patients with mid-distal humeral shaft fractures associated with radial nerve palsies were treated. All patients were male, aged 19-58 years. According to AO/ASIF classification, there were 4 cases of B1 type, 2 cases of B3 type, 1 case of A2 type, 1 caseof B2 type, 1 case of C3 type and 1 case of A3 type. A straight 4.5 mm dynamic compression plate was placed on the anterior aspect of humerus through two small incisions located on the anterior side of proximal and distal part of the arm. The radial nerve exploration was performed through a lateral small incision made on the fracture site. The fractures were then reduced by manual manipulation and the plate was fixated to the main fragments with 3 screws in each end of the plate. The postoperative compl ications, the bone heal ing time, and the recovery time of the radial nerve functions were recorded. The functions of the affected shoulder and elbow were assessed with UCLA and Mayo elbow performance score system respectively. Results All incision healed by first intention. Ten patients were followed up 9-36 months with an average of 15.7 months. The X-ray films showed that the union of fractures was achieved 12-16 weeks (13.6 weeks on average). The function of the radial nerves recovered completely 12-36 weeks (17.8 weeks on average) in 9 patients. The abductions of the affected shoulder were 150-170° (165° on average). The ROM of the elbows were 130-140° (135.5° on average). According to the UCLA shoulder scoring system, 9 patients achieved the excellent result and 1 patient achieved the good result. All the patients had the excellent results according to Mayo elbow performance score system. Conclusion The mid-distal humeral shaft fractures associated with radial nervepalsies can be treated with MIPO technique and the good results can be obtained.
Objective To assess the effectiveness of locking compress plate and extra cortical bone bridge fixation for treating atrophic humeral nonunion. Methods Seventeen patients with atrophic humeral nonuninon were treated with locking compress plate and extra cortical bone bridge fixation between November 2006 and June 2015. Of 17 cases, 11 were male, 6 were female, aged 24-63 years (mean, 38.2 years). Fracture located at the left side in 9 cases and at the right side in 8 cases. The mechanism of injury was traffic accident in 13 cases, falling from height in 3 cases, and heavy pound injury in 1 case. The patients underwent surgery for 1 time in 7 cases, for 2 times in 5 cases, for 3 times in 4 cases, and for 4 times in 1 case. The time from fracture to hospitalization was 10-76 months (mean, 22.6 months). The shoulder function was evaluated by Neer score, and elbow function by Mayo score. Results All incisions healed by first intention. Two cases had transient radial nerve symptoms of numbness. All patients were followed up 27.3 months on average (range, 15-60 months). Radiographic examination showed signs of bone remodeling at 6-8 weeks after operation, and formation of extra cortical bone bridge. All of them achieved bone union within 10 to 41 weeks (mean, 17.6 weeks). At last follow-up, the average Neer score was 83.36 (range, 72-96); and the shoulder function was excellent in 10 cases, good in 5, and fair in 2 with an excellent and good rate of 88.24%. And the average Mayo score was 86.52 (range, 68-100); and the elbow function was excellent in 11 cases, good in 3, and fair in 3 with an excellent and good rate of 82.35%. Conclusion The bone bridging could effectively form by extra cortical grafting technique. Atrophic humeral nonunions can be successfully treated with locking compress plate and extra cortical bone bridge fixation.
ObjectiveTo evaluate the effectiveness of locking compress plate (LCP) for the treatment of aseptic diaphyseal humeral nonunions. MethodsBetween January 2006 and January 2012, 23 patients with aseptic diaphyseal humeral nonuninons were treated with LCP and autologous iliac crest bone graft, and the clinical data were retrospectively analyzed. There were 15 males and 8 females with the average age of 42.5 years (range, 28-60 years). The fracture located at left side in 11 cases and right side in 12 cases. The mechanism of the injury was traffic accident in 15 patients, and falling from height in 8 patients. Fracture was treated by internal fixation in 20 cases and external fixation in 3 cases. And 6 patients had open fractures and other 17 had close fractures. Based on the Weber-Cech classification, 6 cases were rated as atrophic nonunions, and 17 cases as hypertrophic nonuninons. Shoulder function was evaluated by Constant-Murley score and elbow function was evaluated by Mayo score. ResultsAfter operation, 2 patients had transient radial nerve symptoms of numbness and 1 patient had superficial infection. Primary healing of incision was obtained in the other patients. All patients were followed up 22.22 months on average (range, 16-30 months). Normal range of motion of the shoulder was found in 11 cases; and limited movements of abduction, elevation, and posterior extension were observed in 12 cases. And osseous union was observed clinically and radiographically in all patients. The average union time was 16.95 weeks (range, 12-24 weeks). The average Constant-Murley score was 81.87 (range, 50-98); and shoulder function was excellent in 14 cases, good in 6, and fair in 3. And the average Mayo score was 87.78 (range, 70-96); and the result was excellent in 14 cases, good in 7, and fair in 2. ConclusionAseptic diaphyseal humeral nonunions can be successfully treated with LCP, coupled with the use of autologous iliac crest bone graft.
ObjectiveTo evaluate the effectiveness of minimally invasive osteosynthesis using the helical plate for complex humeral shaft fractures involved proximal metaphysis, and to explore its feasibility and security. MethodsA retrospective analysis was made on the clinical data of 16 patients with complex humeral shaft fractures involved proximal metaphysis who underwent minimally invasive osteosynthesis with the helical plate between December 2009 and May 2015. There were 11 males and 5 females, aged from 18 to 56 years (mean, 34.6 years). The causes of fracture included falling injury in 5 cases, falling injury from height in 3 cases, traffic accident injury in 4 cases, sports injury in 3 cases, and belts twisted injury in 1 case. Accroding to Orthopaedic Trauma Association (OTA) classifications, 6 cases were rated as type 12-C1, 3 cases as type 12-C2, and 7 cases as type 12-C3. The time between injury and operation was 2-13 days (mean, 7.2 days). The operation time, intraoperative blood loss, complications, union time were recorded, the functional outcome of the elbow joint was evaluated by Mayo elbow performance score, and the function of the shoulder was assessed by the University of California at Los Angeles (UCLA) shoulder rating scale. ResultsThe mean operation time was 92 minutes (range, 51-127 minutes), and the mean intraoperative blood loss was 212 mL (range, 100-450 mL). All incisions healed by first intention without neurologic complications or wound infection. All patients were followed up 8-28 months (mean, 16.6 months), and bony union was obtained at 13-36 weeks (mean, 19.2 weeks). No loosening or breakage of internal fixation occurred. The Mayo elbow performance score was 90-100 (mean, 99), and the UCLA shoulder rating scale was 31-35 (mean, 34.6). ConclusionThe technique of minimally invasive osteosynthesis using the helical plate is safe and feasible for humeral shaft fracture, especially for complex humeral shaft fractures involved proximal metaphysis, and it has the advantages of minimal invasion and low risk for iatrogenic nerve injury and satisfactory effectiveness.
Objective To compare the efficacy of plating versus intramedullary nailing in the treatment of adult humeral shaft fracture. Methods We identified eligible studies in PubMed (1950 to September 2007), MEDLINE (1950 to September 2007), OVID CINAHL (1950 to September 2007), OVID EBM (3rd Quarter 2007), CBMdisk (1978 to June 2007) and CNKI (1981 to June 2007). We also handsearched several Chinese orthopedic journals. Data were extracted and evaluated by two reviewers independently. Randomized controlled trials (RCTs) comparing plating versus intramedullary nailing for humeral shaft fracture in adults were included and the quality of these trials was critically assessed. Data analyses were conducted with Stata 10.0. Results Six RCTs involving 425 patients were included, among which the statistical heterogeneity was not significant (Pgt;0.1). Cumulative meta-analyses showed that intramedullary nailing might increase the re-operation rate in studies conducted before the year of 2000 (OR=0.39, 95%CI 0.17 to 0.90, P=0.03), but the difference was not significant in studies conducted after 2000 (OR=0.54, 95%CI 0.27 to 1.08, P=0.08). Intramedullary nailing might increase the incidence of shoulder impingement compared with plating (OR=0.13, 95%CI 0.03 to 0.65, P=0.01). The rates of non-union, deep infection, iatrogenic radial nerve injury and internal fixation failure were similar between plating and intramedullary nailing. Meta-analyses were not conducted for union time, operation time and bleeding (transfusion) volume, because the relevant data were not available from the included trials. Conclusion Intramedullary nailing may increase the incidence of shoulder impingement. The rates of re-operation, non-union, deep infection, iatrogenic radial nerve injury and internal fixation failure are similar between plating and intramedullary nailing. Further well-designed and large-scale randomized controlled trials are required to determine the effects of plating and intramedullary nailing on these outcomes.