• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Author
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Author "眭翔" 7 results
        • Construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal printing technology

          Objective To investigate the construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal (3D) printing technology and evaluate its biocompatibility. Methods The fresh pig meniscus was decellularized by improved physicochemical method to obtain decellularized meniscus matrix homogenate. Gross observation, HE staining, and DAPI staining were used to observe the decellularization effect. Toluidine blue staining, safranin O staining, and sirius red staining were used to evaluate the retention of mucopolysaccharide and collagen. Then, the decellularized meniscus matrix bioink was prepared, and the new tissue engineered meniscus scaffold was prepared by low temperature deposition 3D printing technology. Scanning electron microscopy was used to observe the microstructure. After co-culture with adipose-derived stem cells, the cell compatibility of the scaffolds was observed by cell counting kit 8 (CCK-8), and the cell activity and morphology were observed by dead/live cell staining and cytoskeleton staining. The inflammatory cell infiltration and degradation of the scaffolds were evaluated by subcutaneous experiment in rats. Results The decellularized meniscus matrix homogenate appeared as a transparent gel. DAPI and histological staining showed that the immunogenic nucleic acids were effectively removed and the active components of mucopolysaccharide and collagen were remained. The new tissue engineered meniscus scaffolds was constructed by low temperature deposition 3D printing technology and it had macroporous-microporous microstructures under scanning electron microscopy. CCK-8 test showed that the scaffolds had good cell compatibility. Dead/live cell staining showed that the scaffold could effectively maintain cell viability (>90%). Cytoskeleton staining showed that the scaffolds were benefit for cell adhesion and spreading. After 1 week of subcutaneous implantation of the scaffolds in rats, there was a mild inflammatory response, but no significant inflammatory response was observed after 3 weeks, and the scaffolds gradually degraded. Conclusion The novel tissue engineered meniscus scaffold constructed by low temperature deposition 3D printing technology has a graded macroporous-microporous microstructure and good cytocompatibility, which is conducive to cell adhesion and growth, laying the foundation for the in vivo research of tissue engineered meniscus scaffolds in the next step.

          Release date:2024-06-14 09:52 Export PDF Favorites Scan
        • EXTRACTION TECHNIQUES AND BIOCOMPATIBILITY EVALUATIONS OF NATURALLY DERIVED NERVE EXTRACELLULAR MATRIX

          Objective Native extracellular matrix (ECM) is comprised of a complex network of structural and regulatory proteins that are arrayed into a tissue-specific, biomechanically optimal, fibrous matrix. The multifunctional nature of the native ECM will need to be considered in the design and fabrication of tissue engineering scaffolds. To investigate the extraction techniques of naturally derived nerve ECM and the feasibil ity of nerve tissue engineering scaffold. Methods Ten fresh canine sciatic nerves were harvested; nerve ECM material was prepared by hypotonic freeze-thawing, mechanicalgrinding, and differential centrifugation. The ECM was observed by scanning electron microscope. Immunofluorescencestaining was performed to detect specific ECM proteins including collagen type I, laminin, and fibronectin. Total collagen and glycosaminoglycan (GAG) contents were assessed using biochemical assays. The degree of decellularization was evaluated with staining for nuclei using Hoechst33258. The dorsal root gangl ion and Schwann cells of rats were respectively seeded onto nerve tissue-specific ECM films. The biocompatibil ity was observed by specific antibodies for cell markers. Results Scanning electron microscope analysis revealed that nerve-derived ECM consisted of a nanofibrous structure, which diameter was 30-130 nm. Immunofluorescence staining confirmed that the nerve-derived ECM was made up of collagen type I, laminin, and fibronectin. The histological staining showed that the staining results of sirius red, Safranin O, and toluidine blue were positive. Hoechst33258 staining showed no DNA within the decellularized ECM. Those ECM films had good biocompatibil ity for dorsal root gangl ion and Schwann cells. The cotents of total collagen and GAG in the nerve-derived ECM were (114.88 ± 13.33) μg/ mg and (17.52 ± 2.34) μg/mg, showing significant difference in the content of total collagen (P lt; 0.01) and no significant difference in the content of GAG (P gt; 0.05) when compared with the contents of normal nerve tissue [(54.07 ± 5.06) μg/mg and (25.25 ± 1.56) μg/mg)]. The results of immunofluorescence staining were positive for neurofilament 200 after 7 days and for S100 after 2 days. Conclusion Nerve-derived ECM is rich in collagen type I, laminin, and fibronectin and has good biocompatibil ity, so it can be used as a nerve tissue engineering scaffold.

          Release date:2016-08-31 05:49 Export PDF Favorites Scan
        • EFFECT OF CONTROLLED RELEASE NERVE GROWTH FACTOR ON REPAIRING PERIPHERAL NERVEDEFECT BY ACELLULAR NERVE GRAFT

          Objective To explore the effect of controlled release of nerve growth factor (NGF) on peripheral nerve defect repaire by acellular nerve graft. Methods The microspheres of NGF were prepared with drug microsphere technologyand fixed with the fibrin glue to make the compl icated controlled release NGF. Twenty healthy male SD rats weighing 280-300 g were adopted to prepare acellular xenogenous nerve, 52 male Wistar rats weighing 250-300 g were adopted to prepare the 10 mm defect model of left sciatic nerve. and thereafter were randomly divided into 4 groups: autograft group(group A), acellular nerve allograft combined with the double controlled release NGF (group B), acellular nerve allograft (group C) and acellular nerve allograft combined with fibrin glue (group D). Without any operation, the right sciatic nerve was regarded as control group. General observation was conducted after operation. The nerve axon regeneration length was measured 2 weeks after operation. The effects of peripheral nerve regeneration were evaluated by neural electrophysiology, the recovery rate of triceps surae muscular tension and weight and histological assessment 16 weeks after operation. Results All the animals survived till the end of experiment. The length of nerve regeneration was measured at 2 weeks after transplantation. The regeneration nerve of group A was longer than that of other groups (P lt; 0.05), group B longer than groups C and D (P lt; 0.05), and there were no difference between group C and group D (P gt; 0.05). At 16 weeks after operation, the recovery rates of nerve conduction velocity of groups A and B (73.37% ± 7.82% and 70.39% ± 8.45%) were larger than that of groups C and D (53.51% ± 6.31% and 55.28% ± 5.37%) (P lt; 0.05). The recovery rates of the triceps surae muscular tension in group A (85.33% ± 5.59%) were larger than that in groups B, C and D (69.79% ± 5.31%, 64.46% ± 8.49% and 63.35% ± 6.40%) (P lt; 0.05). There were no significant differences among groups B, C and D (P gt; 0.05). The recovery rates of the triceps surae weight in group A (62.54% ± 8.25%) werelarger than that in groups B, C and D (53.73% ± 4.56%, 46.37% ± 5.68% and 45.78% ± 7.14%, P lt; 0.05). There was significant difference between group B and groups C, D (P lt; 0.05) and no significant differences between group C and group D (P gt; 0.05). The histological observation indicated that axon number and myel in thickness in group B were larger than those in group C and group D (P lt; 0.05). The axonal diameter in group B was significantly less than that in group A (P lt; 0.05). Conclusion Acellular nerve graft combined with the controlled release NGF is a satisfactory alternative to repair the peripheral nerve defect.

          Release date:2016-09-01 09:19 Export PDF Favorites Scan
        • In vivo degradation of magnesium alloys and poly (lactic-co-glycolic acid) and degradation evaluation of magnesium alloys using micro-ct

          ObjectiveTo explore the degradation of AZ31 magnesium alloy and poly (lactic-co-glycolic acid) (PLGA) in the femoral condyle, and then evaluate the laws of degradation of AZ31 magnesium alloy by Micro-CT images and data. MethodsForty 3-month-old male New Zealand white rabbits (weighing, 2.5 kg) were randomly divided into 4 groups, 10 rabbits each group. Forty micro-arc-oxidized AZ31 magnesium alloy pins and 40 PLGA pins were implanted into the right and left femoral condyle, respectively. Micro-CT images and data analysis were used to evaluate the degradation at 4, 8, 12, and 16 weeks after operation (n=10). Degradation was evaluated by weight difference between pre-and post-implantation. The inflammatory response was observed around the implants by HE staining. The weight loss of magnesium alloy and Micro-CT results were compared. ResultsThe Micro-CT images showed that PLGA pins had gray low signal, which was similar to the soft tissue around. At 4 weeks after operation, no signs of degradation were observed, and there were little corrosion pitting on the magnesium alloy. At 8 weeks, corrosion pitting gradually expanded, the boundary between the longitudinal axis and the cross section became blurred; at 16 weeks, corrosion pitting became bigger, and the boundary was discontinuous. Micro-CT quantitative analysis showed that the volume fraction of magnesium pins decreased slowly at 4 and 8 weeks; it was significantly lower at 12 and 16 weeks than 4 and 8 weeks (P < 0.05). The magnesium cylinder mineral density continuously decreased during the study period, it had a rapidly speed from 12 to 16 weeks (P < 0.05). However, the magnesium CT image density showed a slight change (P>0.05). The surface-to-volume ratio of the pins constantly increased, and the ratio was significantly larger at 12 and 16 weeks than 4 and 8 weeks, and at 16 weeks than 12 weeks (P < 0.05). There was more and more corrosion pitting on the surface with time, which resulted in a decrease in the radius that mean trabecular thickness gradually decreased, showing significant difference between different time points after 8 weeks (P < 0.05). The weight loss detection showed that the degradation of magnesium pin and PLGA gradually increased with time (P < 0.05), and the degradation rate of magnesium pin was significantly lower than that of PLGA at 8-12 weeks (P < 0.05), but the degradation rate of magnesium pin was higher than that of PLGA at 16 weeks. At each time point, the weight loss of magnesium alloy was similar to that by Micro-CT, but mass fraction was lower than volume fraction and had significant differences at 8, 12, and 16 weeks (P < 0.05). HE staining revealed that slight inflammatory response was observed around the magnesium pins at 4 weeks, and inflammatory reaction gradually reduced with time and disappeared at 16 weeks, but no inflammatory reaction was seen around PLGA. ConclusionMicro-CT has the advantages of non-trauma, in vivo detection, quantitative analysis, and precise data in evaluating the degradation of AZ31 magnesium alloy. Regarding the degradation of the magnesium alloy and PLGA in vivo, the degradation rate is slow in the early stage, and then increases with time. The degradation of PLGA is faster and earlier but it is then overtaken by AZ31 magnesium alloy at 16 weeks. During the degradation, the density of the magnesium has almost no change. The biomaterials can not firmly attach to the surrounding tissues due to inadequate holding forces.

          Release date: Export PDF Favorites Scan
        • HISTOMORPHOLOGY OBSERVATION OF CANINE WHOLE FACIAL NERVE TREATED WITH CHEMICALLY EXTRACTED ACELLULAR METHODS

          Objective Using chemically extracted acellular methods to treat extracranial section of the canine whole facial nerve, to evaluated its effects on nerve structure and the removal extent of Schwann cells and myel in. Methods Twenty whole facial nerves were exposed from 10 canines [weighing (18 ± 3) kg]. The extracranial trunk of canine facial nerve and its branches (temporal branch, zygomatic branch, buccal branch, marginal mandibular branch, and cervical branch) were dissected under l ight microscope. Twenty facial nerves were divided into the experimental group (n=12) and control group (n=8) randomly. In experimental group, the nerve was extracted with the 3%TritonX-100 and 4% sodium deoxycholate. In control group, the nerve was not extracted. HE staining and immunofluorescence histological stainings for Hoechst33258, P75, Zero, and Laminin were performed. Results After histological staining, it was found that myel in and Schwann cells were removed from the facial nerve while the basal lamina tube remained intact. The whole canine facial nerves (one nerve trunk and multiple nerve branches) had the similar result. Conclusion The canine whole facial nerve has natural structure (one nerve trunk and multiple nerve branches) by extracted with chemically extracted acellular methods, so it is an available graft for repairing the defect of the whole facial nerve.

          Release date:2016-08-31 05:48 Export PDF Favorites Scan
        • Electrospun polycaprolactone/collagen typeⅠnanofibers oriented patch for rotator cuff repairing

          ObjectiveElectrospinning technique was used to manufacture polycaprolactone (PCL)/collagen typeⅠ nanofibers orientated patches and to study their physical and chemical characterization, discussing their feasibility as synthetic patches for rotator cuff repairing.MethodsPCL patches were prepared by electrospinning with 10% PCL electrospinning solution (control group) and PCL/collagen typeⅠorientated nanofibers patches were prepared by electrospinning with PCL electrospinning solution with 25% collagen type Ⅰ(experimental group). The morphology and microstructure of the two patches were observed by gross and scanning electron microscopy, and the diameter and porosity of the fibers were measured; the mechanical properties of the patches were tested by uniaxial tensile test; the composition of the patches was analyzed by Fourier transform infrared spectroscopy; and the contact angle of the patch surface was measured. Two kinds of patch extracts were co-cultured with the third generation of rabbit tendon stem cells. Cell counting kit 8 (CCK-8) was used to detect the toxicity and cell proliferation of the materials. Normal cultured cells were used as blank control group. Rabbit tendon stem cells were co-cultured with the two patches and stained with dead/living cells after 3 days of in vitro culture, and laser confocal scanning microscopy was used to observe the cell adhesion and activity on the patch.ResultsGross and scanning electron microscopy showed that the two patch fibers were arranged in orientation. The diameter of patch fibers in the experimental group was significantly smaller than that in the control group (t=26.907, P=0.000), while the porosity in the experimental group was significantly larger than that in the control group (t=2.506, P=0.032). The tensile strength and Young’s modulus of the patch in the experimental group were significantly higher than those in the control group (t=3.705, P=0.029; t=4.064, P=0.034). Infrared spectrum analysis showed that PCL and collagen type Ⅰ were successfully mixed in the experimental group. The surface contact angle of the patch in the experimental group was (73.88±4.97)°, which was hydrophilic, while that in the control group was (128.46±5.10) °, which was hydrophobic. There was a significant difference in the surface contact angle between the two groups (t=21.705, P=0.002). CCK-8 test showed that with the prolongation of culture time, the cell absorbance (A) value increased gradually in each group, and there was no significant difference between the experimental group and the control group at each time point (P>0.05). Laser confocal scanning microscopy showed that rabbit tendon stem cells could adhere and grow on the surface of both patches after 3 days of culture. The number of cells adhered to the surface of the patches in the experimental group was more than that in the control group, and the activity was better.ConclusionPCL/ collagen type Ⅰ nanofibers orientated patch prepared by electrospinning technology has excellent physical and chemical properties, cell adhesion, and no cytotoxicity. It can be used as an ideal scaffold material in tendon tissue engineering for rotator cuff repair in the future.

          Release date:2019-05-06 04:48 Export PDF Favorites Scan
        • FLUORESCENCE DISTRIBUTION IN BONE AND CARTILAGE TISSUE BY SECTIONING OF FROZEN UNDECALCIFIED BONE

          ObjectiveTo introduce a technique of frozen sections for undecalcified bone and discuss its feasibility by observing the fluorescence distribution of the bone and cartilage. MethodsThe male Sprague Dawley transgenic rats at the age of 8 weeks, which express green fluorescent protein were selected to isolate the whole knee sectioned by the undecalcified bone frozen section technique. Under the fluorescence and light microscopy, the fluorescence and structure were observed within the organization of slice. Immunohistochemical staining (collagen type Ⅰ and Ⅱ), HE staining, toluidine blue staining, and Alizarin red staining were performed to observe the distribution of fluorescent substance and cartilage and bone structure. ResultsThe thickness of sections prepared by this technology was 6 μm. General observation showed that the structure of sectioned joint was complete. Under the light microscope, the morphology of cartilage cells, the arrangement of subchondral bone, and trabecular bone traveling could be clearly distinguished. Under fluorescence microscope, green fluorescence was shown in the joint soft tissue, cartilage tissue, and bone tissue; collagen type Ⅰ expressed in the bone tissue, collagen type Ⅱ in cartilage tissue. HE staining and toluidine blue staining could clearly distinguish the morphology of the cartilage layer. Alizarin red staining showed the structural integrity of subchondral bone plate and the organization within the meniscus, and proximal tibia cortical bone continuity. ConclusionThe fluorescence distribution can be directly observe in the bone and cartilage by sectioning of frozen undecalcified bone. This new technology can shorten the cycle of preparing sections.

          Release date: Export PDF Favorites Scan
        1 pages Previous 1 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜