A series of 28 cases of fractures of the small tubular bones of the hand, including Bennetts fracture, were treated with the minor unilateral multifunctional external fixator. After manipulation, a hole was drilled on the proximal and distal parts of the fractured bone. Hand in functional position, the external fixator was set in place. Functional exercises were begun after the fixation. The patients were follwed up for two to six months. The average healing time was thirtyfive days. The average healing time for Bennett’s fractures was twentyeight days, and for the fractures of metacarpal bone was forty-two days. There were no deformity and complication of infection following external fixation.The functional recovery of the hands was satisfactory. The fixator had the following advantages: It was simple and had tight fixation; fractures with infection, was still indicated and could be adjusted according to the clinical purpose.
Six cases of old fracture of the tibia with large sear, bony defect, and shortening deformity of the limb were treated by elongation osteotomy at epiphysis and compression fixation of the fracture with external semilunar fixation frame. The bony defect ranged from 3cm to 6cm. Bony healing developed in all patients 4-7 months after operation. Early postoperative movement was suggested. The results revealed that there was an obvious improvement of the joint function and the shortened legs were corrected. The advantages of this method are that there is no need of bone grafting and operative treatment of the scar prior to treatment of the bone.
ObjectiveTo investigate the effectiveness of limited internal fixation combined with hinged super-articular external fixator to treat type C3 fracture of the distal humerus. MethodsBetween September 2007 and November 2012, 37 cases of type C3 fracture of the distal humerus were treated. There were 22 males and 15 females with an average age of 43.6 years (range, 22-66 years). The causes were accident injury in 24 cases, falling injury in 5 cases, falling from height in 4 cases, heavy crush injury in 2 cases, machine injury in 1 case, and other injury in 1 case. There were 22 cases of open injury and 15 cases of closed injury. The time from injury to operation was 3-46 hours (mean, 18 hours). ResultsNeedle tract reaction and incision infection occurred in 3 cases and 1 case respectively, healing of incision by first intension was obtained in the other cases. Thirty-six patients were followed up 9-48 months (mean, 25.4 months). Heterotopic ossification occurred in 3 cases after operation and no recurrence was found by release after fracture healing. Fractures healed in the other patients after 6-14 months (mean, 9 months) of operation except 1 patient who suffered chronic osteomyelitis. One patient had delayed ulnar neuritis at 12 months after operation, and the nerve function returned to normal after the ulnar nerve transposition. There was no bone ischemic necrosis, elbow joint instability, or loosening of internal fixation. At last follow-up, the average range of motion of injured elbow was 105.0° in flexion,-25.0° in extension, 69.2° in pronation, and 75.6° in supination. According to Mayo elbow joint function score (MEPS) and disability of arm shoulder and hand (DASH) score, the results were excellent in 22 cases, good in 8 cases, fair in 4 cases, and poor in 2 cases with an excellent and good rate of 83.3%; and according to Cassebaum elbow joint function score, the results were excellent in 21 cases, good in 7 cases, fair in 5 cases, and poor in 3 cases with an excellent and good rate of 77.8%. ConclusionA combination of limited internal fixation and hinged super-articular external fixator has satisfactory clinical curative effect for type C3 fractures of the distal humerus, relatively few complications.
Objective To investigate the antibacterial and osteogenic capabil ities in vivo of hydroxyapatite (HA)/silver (Ag) coating. Methods HA/Ag coating (Ag qual ity percentage was 3%) and HA coating were deposited to external fixator Schanz screws. The tibial fracture model was establ ished in right hindl imb of 18 adult male Beagle dogs (weighing 15-20 kg). Thetibia was stabil ized with an external fixator and 2 Schanz screws of HA coating at proximal tibia (control group, n=18) and HA/Ag coating at distal tibia (experimental group, n=18), and every screw incision was infected with Staphylococcus aureus. Infection in screw holes and the changes of bone-screw interface were observed by wound grading and X-ray films. Results In control group, wounds infection became worse with time (χ2=13.492, P=0.001), while in experimental group, no obvious change was observed (χ2=0.208, P=0.901). The wound grading of experimental group was significantly better than that of the control group at 1, 2, and 3 weeks (P lt; 0.05). Laser scanning confocal microscope showed that there was bacterial adhesion on the surface of screws in 2 groups, viable becteria mainly in control group and non-viable becteria mainly in experimental group. The scanning electron microscope (SEM) observation results of the fractured sclerous tissue section showed that an obvious transparent boundary between screw and bone in control group, but no obvious boundary in experimental group. The osseointegration ratios were 76.23% ± 15.54% in control group and 93.42% ± 5.53% in experimental group, showing significant difference (t=8.843, P=0.000). The SEM observation showed that HA/Ag coating integrated with new bone and the surface of implant was filled with new bone in experimental group; obvious interspace was seen between the HA coating and new bone in control group. Conclusion HA/Ag coating has good antibacterial and osteogenic capabil ities, so it can take effects in preventing infection in screw holes and loosening of implants.
目的:評價外固定支架治療橈骨遠端骨折的療效。方法:2004年3月至2008年8月以外固定支架或輔以克氏針、可吸收螺釘內固定治療橈骨遠端骨折37例。結果:31例獲得4~28 個月(平均14 個月)的隨訪,所有骨折均臨床愈合,平均愈合時間8周。腕關節功能按Sarmiento標準進行評定,優17例,良9例,可4例,差1例,優良率839%。結論:外固定支架治療橈骨遠端骨折療效可靠,值得推廣。
【摘要】 目的 探討多功能外固定支架治療老年股骨粗隆間骨折的療效和優點。 方法 2007年7月-2009年10月,采用外固定架治療28例老年股骨粗隆間骨折患者,其中男11例,女17例;年齡74~91歲,平均81歲。致傷原因:摔傷25例,交通事故傷3例。骨折按Evans分型:Ⅰ型1例,Ⅲ型15例,Ⅳ型12例。受傷至手術時間2~7 d。 結果 術后患者切口均Ⅰ期愈合,無延遲愈合及其他早期并發癥發生。28例均獲隨訪,隨訪時間5~14個月,平均9個月。X線片示骨折全部愈合,愈合時間11~24周,平均17周。無髖內翻和下肢短縮等并發癥發生。術后3個月,采用Harris評分進行功能評價,優18例,良7例,差3例,優良率89.3%。出現輕度針道感染7例,中度5例,重度2例,針道感染率50%;合并糖尿病者2例出現中度針道感染,2例出現重度針道感染。重度者經局部換藥、應用抗生素后愈合,后又反復出現,2~3個月取釘后愈合。無骨感染發生,患者均未出現褥瘡,合并癥無明顯加重。 結論 外固定架治療粗隆間骨折,手術創傷小,操作簡便,符合生物力學原理,可以早期離床活動及早期骨折愈合。【Abstract】 Objective To explore the effectiveness and advantages of multifunctional external fixator for the treatment of femoral intertrochanteric fractures in the elderly patients. Methods Twenty-eight patients with femoral intertrochanteric fractures including 11 males and 17 females receiving external fixator treatment between July 2007 and October 2009 were enrolled in this study. Their age ranged from 74 to 91 years old with the average to be 81 years. Twenty-five patients had the disease because of ground falls, and the other 3 were due to traffic accidents. Based on the Evans Type classification, there were 1 Type-Ⅰ case, 15 Type-Ⅲ cases, and 12 Type-Ⅳ cases. The time between injury and surgery was ranged from 2 to 7 days. Results All incisions of the patients healed during phase Ⅰ without delayed healing or other early complications. Follow-up was done to all the patients for 5 to 14 months, averaging 9 months. X-ray showed all fractures healed, and the healing time ranged from 11 to 24 weeks with an average of 17 weeks. No varus or leg shortening or other complications occurred. Three months after surgery, based on the Harris hip score for functional evaluation, there were 18 excellent cases, 7 good cases and 3 poor cases with a excellent and good rate of 89.3%. Mild pin tract infection was detected in 7 patients, moderate in 5, and severe in 2 with a total pin tract infection rate of 50%. Two patients with diabetes suffering from severe pin tract infection recovered by local medication and antibiotics, but the infection reoccurred repeatedly till the healing nails were taken. No bone infection of ulcers occurred, and the existing complications were not aggravated. Conclusion Treatment of intertrochanteric fractures with multifunctional external fixator is minimally invasive, simple, and consistent with biomechanical principles, which can promote early activities out of bed and early fracture healing for the patients.