• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "wavelet transform" 23 results
        • Medical Image Processing Based on Wavelet Characteristics and Edge Blur Detection

          To solve the problems of noise interference and edge signal weakness for the existing medical image, we used two-dimensional wavelet transform to process medical images. Combined the directivity of the image edges and the correlation of the wavelet coefficients, we proposed a medical image processing algorithm based on wavelet characteristics and edge blur detection. This algorithm improved noise reduction capabilities and the edge effect due to wavelet transformation and edge blur detection. The experimental results showed that directional correlation improved edge based on wavelet transform fuzzy algorithm could effectively reduce the noise signal in the medical image and save the image edge signal. It has the advantage of the high-definition and de-noising ability.

          Release date: Export PDF Favorites Scan
        • Comparative Study on the Three Algorithms of T-wave End Detection: Wavelet Method, Cumulative Points Area Method and Trapezium Area Method

          In order to find the most suitable algorithm of T-wave end point detection for clinical detection, we tested three methods, which are not just dependent on the threshold value of T-wave end point detection, i.e. wavelet method, cumulative point area method and trapezium area method, in PhysioNet QT database (20 records with 3 569 beats each). We analyzed and compared their detection performance. First, we used the wavelet method to locate the QRS complex and T-wave. Then we divided the T-wave into four morphologies, and we used the three algorithms mentioned above to detect T-wave end point. Finally, we proposed an adaptive selection T-wave end point detection algorithm based on T-wave morphology and tested it with experiments. The results showed that this adaptive selection method had better detection performance than that of the single T-wave end point detection algorithm. The sensitivity, positive predictive value and the average time errors were 98.93%, 99.11% and (-2.33±19.70) ms, respectively. Consequently, it can be concluded that the adaptive selection algorithm based on T-wave morphology improves the efficiency of T-wave end point detection.

          Release date: Export PDF Favorites Scan
        • Motor Cortex Functional Mapping Using Electrocorticography

          The main shortcomings of using electrocortical stimulation (ECS) in identifying the motor functional area around the focus in neurosurgery are certainly time-consuming, possibly cerebral cortex injuring and perhaps triggering epilepsy. To solve these problems, we in our research presented an intraoperative motor cortex functional mapping based on electrocorticography (ECoG). At first, using power spectrum estimation, we analyzed the characteristic of ECoG which was related to move task, and selected Mu rhythm as the move-related feature. Then we extracted the feature from original ECoG by multi-resolution wavelet analysis. By calculating the sum value of feature in every channel and observing the distribution of these sum values, we obtained the correlation between the cortex area under the electrode and motor cortex functional area. The results showed that the distribution of the relationship between the cortex under the electrode and motor cortex functional area was almost consistent with those identified by ECS which was called as ‘the gold-standard’. It indicated that this method was basically feasible, and it just needed five minutes totally. In conclusion, ECoG-based and passive identification of motor cortical function may serve as a useful adjunct to ECS in the intraoperative mapping.

          Release date: Export PDF Favorites Scan
        • Research on the detection algorithm of electrocardiogram characteristic wave based on energy segmentation and stationary wavelet transform

          The detection of electrocardiogram (ECG) characteristic wave is the basis of cardiovascular disease analysis and heart rate variability analysis. In order to solve the problems of low detection accuracy and poor real-time performance of ECG signal in the state of motion, this paper proposes a detection algorithm based on segmentation energy and stationary wavelet transform (SWT). Firstly, the energy of ECG signal is calculated by segmenting, and the energy candidate peak is obtained after moving average to detect QRS complex. Secondly, the QRS amplitude is set to zero and the fifth component of SWT is used to locate P wave and T wave. The experimental results show that compared with other algorithms, the algorithm in this paper has high accuracy in detecting QRS complex in different motion states. It only takes 0.22 s to detect QSR complex of a 30-minute ECG record, and the real-time performance is improved obviously. On the basis of QRS complex detection, the accuracy of P wave and T wave detection is higher than 95%. The results show that this method can improve the efficiency of ECG signal detection, and provide a new method for real-time ECG signal classification and cardiovascular disease diagnosis.

          Release date:2022-02-21 01:13 Export PDF Favorites Scan
        • Comparative study on evaluation algorithms for neck muscle fatigue based on surface electromyography signal

          The purpose of this study is to compare the differences among neck muscle fatigue evaluation algorithms and to find a more effective algorithm which can provide a human factor quantitative evaluation method for neck muscle fatigue during bending over the desk. We collected surface electromyography signal of sternocleidomastoid muscle of 15 subjects using wireless physiotherapy Bio-Radio when they bent over the desk using memory pillows for 12 minutes. Five algorithms including mean power frequency, spectral moments ratio, discrete wavelet transform, fuzzy approximation entropy and the complexity algorithms were used to calculate the corresponding muscle fatigue index. The least squares method was used to calculate the corresponding coefficient of determination R2 and slope k of the linear regression of the muscle fatigue metric. The coefficient of determination R2 evaluates anti-interference ability of algorithms. The maximum vertical distance Lmax which is obtained by the Kolmogorov-Smirnov test for the slopes k evaluates the ability to distinguish fatigue of algorithms. The results indicate that in the aspect of anti-interference ability, the fuzzy approximation entropy has the largest R2 when using memory pillows with different heights. When the fuzzy approximate entropy is compared with average power frequency or the discrete wavelet transform, the differences are significant (P < 0.05). In terms of distinguishing the degree of fatigue, the approximate entropy is still the largest, with a maximum of 0.496 7. Fuzzy approximation entropy is superior to other algorithms in ability of anti-interference and distinguishing fatigue. Therefore, fuzzy approximation entropy can be used as a better evaluation algorithm in the evaluation of cervical muscle fatigue.

          Release date:2018-02-26 09:34 Export PDF Favorites Scan
        • Synchronous analysis of corticomuscular coherence based on Gabor wavelet-transfer entropy

          Synchronization analysis of electroencephalogram (EEG) and electromyogram (EMG) could reveal the functional corticomuscular coupling (FCMC) during the motor task in human. A novel method combining Gabor wavelet and transfer entropy (Gabor-TE) is proposed to quantitatively analyze the nonlinearly synchronous corticomuscular function coupling and direction characteristics under different steady-state force. Firstly, the Gabor wavelet transform method was used to acquire the local frequency-band signals of the EEG and EMG signals recorded from nine healthy controls simultaneously during performing grip task with four different steady-state forces. Secondly, the TE of local frequency-band was calculated and the unit area index of the transfer (ATE) was defined to quantitatively analyze the synchronous corticomuscular function coupling and direction characteristics under steady-state force. Lastly, the effect of EEG and EMG signal power spectrum on Gabor-TE analysis was explored. The results showed that the coupling strength in the beta band was stronger in EEG→EMG direction than in EMG→EEG direction, and the ATE values in the beta band in EEG→EMG direction decreased with the force increasing. It is also shown that the difference in TE values of gamma band present a varying regularity as the increase of force in both directions. In addition, EMG power spectrum was significantly correlated with the result of Gabor-TE inspecific frequency band. The results of our study confirmed that Gabor-TE can quantitatively describe the nonlinearly synchronous corticomuscular function coupling in both local frequency band and information transmission. The analysis of FCMC provides basic information for exploring the motor control and the evaluation of clinical rehabilitation.

          Release date:2017-12-21 05:21 Export PDF Favorites Scan
        • Research on Pretreatment and Envelope Extraction Algorithm of Heart Sound Signal

          In this work, a new method of heart sound signal preprocessing is presented. First, the heart sound signals are decomposed by using multilayer wavelet transform. And then double parameters as thresholds are used in processing each layer after decomposition for denoising. Next, reconstruction of heart sound signals could be done after processing last layer. Four methods, i.e. wavelet transform, Hilbert-Huang transform (HHT), mathematical morphology, and normalized average Shannon energy, were used to extract the envelop of the heart sound signals respectively after reconstruction of heart sounds. All methods were improved in this study. We finally in our study chose 30 cases of raw heart sound signals, which were selected randomly from a database comed from The Clinical Medicine Institute of Montreal, and processed them by using the improved methods. The results were satisfactory. It showed that the extracted envelope with the original signal has a high degree of matching, whether it is a low frequency portion or high frequency portion. Most of all information of heart sound has been maintained in the envelope.

          Release date: Export PDF Favorites Scan
        • Research on automatic removal of ocular artifacts from single channel electroencephalogram signals based on wavelet transform and ensemble empirical mode decomposition

          The brain-computer interface (BCI) systems used in practical applications require as few electroencephalogram (EEG) acquisition channels as possible. However, when it is reduced to one channel, it is difficult to remove the electrooculogram (EOG) artifacts. Therefore, this paper proposed an EOG artifact removal algorithm based on wavelet transform and ensemble empirical mode decomposition. Firstly, the single channel EEG signal is subjected to wavelet transform, and the wavelet components which involve EOG artifact are decomposed by ensemble empirical mode decomposition. Then the predefined autocorrelation coefficient threshold is used to automatically select and remove the intrinsic modal functions which mainly composed of EOG components. And finally the ‘clean’ EEG signal is reconstructed. The comparative experiments on the simulation data and the real data show that the algorithm proposed in this paper solves the problem of automatic removal of EOG artifacts in single-channel EEG signals. It can effectively remove the EOG artifacts when causes less EEG distortion and has less algorithm complexity at the same time. It helps to promote the BCI technology out of the laboratory and toward commercial application.

          Release date:2021-08-16 04:59 Export PDF Favorites Scan
        • An improved electroencephalogram feature extraction algorithm and its application in emotion recognition

          The result of the emotional state induced by music may provide theoretical support and help for assisted music therapy. The key to assessing the state of emotion is feature extraction of the emotional electroencephalogram (EEG). In this paper, we study the performance optimization of the feature extraction algorithm. A public multimodal database for emotion analysis using physiological signals (DEAP) proposed by Koelstra et al. was applied. Eight kinds of positive and negative emotions were extracted from the dataset, representing the data of fourteen channels from the different regions of brain. Based on wavelet transform, δ, θ, α and β rhythms were extracted. This paper analyzed and compared the performances of three kinds of EEG features for emotion classification, namely wavelet features (wavelet coefficients energy and wavelet entropy), approximate entropy and Hurst exponent. On this basis, an EEG feature fusion algorithm based on principal component analysis (PCA) was proposed. The principal component with a cumulative contribution rate more than 85% was retained, and the parameters which greatly varied in characteristic root were selected. The support vector machine was used to assess the state of emotion. The results showed that the average accuracy rates of emotional classification with wavelet features, approximate entropy and Hurst exponent were respectively 73.15%, 50.00% and 45.54%. By combining these three methods, the features fused with PCA possessed an accuracy of about 85%. The obtained classification accuracy by using the proposed fusion algorithm based on PCA was improved at least 12% than that by using single feature, providing assistance for emotional EEG feature extraction and music therapy.

          Release date:2017-08-21 04:00 Export PDF Favorites Scan
        • An anesthesia depth computing method study based on wavelet transform and artificial neural network

          General anesthesia is an essential part of surgery to ensure the safety of patients. Electroencephalogram (EEG) has been widely used in anesthesia depth monitoring for abundant information and the ability of reflecting the brain activity. The paper proposes a method which combines wavelet transform and artificial neural network (ANN) to assess the depth of anesthesia. Discrete wavelet transform was used to decompose the EEG signal, and the approximation coefficients and detail coefficients were used to calculate the 9 characteristic parameters. Kruskal-Wallis statistical test was made to these characteristic parameters, and the test showed that the parameters were statistically significant for the differences of the four levels of anesthesia: awake, light anesthesia, moderate anesthesia and deep anesthesia (P < 0.001). The 9 characteristic parameters were used as the input of ANN, the bispectral index (BIS) was used as the reference output, and the method was evaluated by the data of 8 patients during general anesthesia. The accuracy of the method in the classification of the four anesthesia levels of the test set in the 7:3 set-out method was 85.98%, and the correlation coefficient with the BIS was 0.977 0. The results show that this method can better distinguish four different anesthesia levels and has broad application prospects for monitoring the depth of anesthesia.

          Release date:2021-12-24 04:01 Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜