【Abstract】 Objective To study the influence of close-box and open-box knee prosthesis on postoperative bloodloss in patients undergoing total knee replacement(TKR). Methods From June 2005 to December 2006, 108 atients with primaryknee osteoarthritis were treated with TKR. Closed-box knee prosthesis was used in 54 patients (Group A), including unilateral(Group A1, n =27)and bilateral (Group A2, n =27). There were 7 males and 47 females, aged 41-76 years; and the diseasecourse was 4-16 years. Open-box knee prosthesis was used in 54 patients(Group B), including unilateral (Group B1, n =27)andbilateral(Group B2, n =27). There were 8 males and 46 females, aged from 59-81 years; and the disease course was 8-26 years. Thepostoperative blood loss and perioperative blood loss were compared between groups. Results The postoperative blood losswas (890±352), (1 694±528), (1 068±386) and(2 065±622) mL in groups A1, A2, B1 and B2, respectively. There was no significantdifference between groups A1 and B1(P gt; 0.05). There was significant difference between groups A2 and B2(P lt; 0.05). The totalblood loss was (1 095±329), (2 082±594), (1 274±415) and (2 459±734) mL in groups A1, A2, B1 and B2, respectively. Therewas no significant difference between groups A1 and B1(P gt; 0.05). There was significant difference between groups A2 and B2(P lt; 0.05). Conclusion Closed-box knee prosthesis may play roles on reducing postoperative blood loss. The main influentialfactor for postoperative blood loss is operation techniques which includes reducing operation time and stanching thoroughlyduring operation.
Objective To discuss the clinical application of preserving femoral neck in total hip arthroplasty and to analyze the early stage results.Methods From January 1999 to June 2001, 12 patients underwent total hip arthroplasty with preservation of femoral neck. We cut off the femoral head in infra-head position with improved Moore micro-incisions to reserve intact neck of femur. Thensuitable size of extra cup was selected and placed at 55° eversion angle. The internal cup, made from ultra high polymer poly thene and with ultra radius design, was placed at 45°eversion angle. Harris scores were recorded before operation, after operation and during the follow-up. During the follow-up, the X-rayfilms were taken to assess position, loosening of the prosthesis and ectopic ossification.Results All 12 patients were followed up 2-4.5years with an average of 3.1 years. The mean Harris score of hip elevated from 54 scores before operation to 92 scores of the last follow-up. Mild ectopic ossification occurred in 3 cases. There was no prosthesis loosening and femoral prosthesis setting, and only onepatient had mild bone absorption around femoral prosthesis.Conclusion Total hip arthroplasty with femoral neck preservation is a good option for the patients who need total hip arthroplasty for variable reasons, which is indicated for the patients whose femoral neck is intact with no osteoporosis.
Objective To evaluate the feasibility and short-term effectiveness of three-dimensional (3D) printed titanium-alloy prosthesis reconstruction after the distal tibia tumor segment resection. Methods The clinical data of 6 patients with bone defect after distal tibia tumor segment resection treated with 3D printed titanium-alloy prosthesis reconstruction and tibiotalar joint fusion between January 2020 and December 2021 were retrospectively analyzed. There were 2 males and 4 females; the age ranged from 12 to 35 years, with an average of 18.5 years. Among them, 4 cases were osteosarcoma, 1 case was Ewing sarcoma, and 1 case was giant cell tumor of bone. The Enneking staging was stage ⅡA in 3 cases, stage ⅡB in 2 cases, and stage Ⅲ in 1 case. The disease duration was 2-5 months (mean, 3.2 months). All patients received preoperative neoadjuvant therapy, and patients with osteosarcoma and Ewing sarcoma started chemotherapy at3 weeks after operation. The systemic and local tumor conditions and prosthesis conditions were evaluated regularly after operation. The Musculoskeletal Tumor Society (MSTS) score and the American Orthopaedic Foot and Ankle Society (AOFAS) score were used to evaluate the lower extremity and ankle function. Results All patients were followed up 8-26 months, with an average of 15.6 months. There was no local recurrence and distant metastasis during the follow-up. The ankle joints of 5 cases were all in 90° functional position at last follow-up, and there was no complication such as prosthesis loosening and fracture; the ankle joint fusion was stable, the local bone ingrowth was good, and the daily activities could be completed, but the ankle range of motion was limited and the ankle joint was stiff. The MSTS score ranged from 22 to 26, with an average of 24, and 3 cases were evaluated as excellent and 2 cases were good; the AOFAS score ranged from 71 to 86, with an average of 80.6, and 4 cases were evaluated as good and 1 case was fair. One patient had severe periprosthetic infection at 2 months after operation, resulting in failure of prosthesis implantation, pain in limb movement, and poor ankle function; MSTS score was 12, AOFAS score was 50, and both were evaluated as poor; distraction osteogenesis was performed after removal of prosthesis and infection control, at present, it was still in the process of distraction osteogenesis, and local osteogenesis was acceptable. Conclusion Using 3D printed titanium-alloy prosthesis and tibiotalar joint fusion to reconstruct the bone defect after distal tibia tumor segment resection has satisfactory mechanical stability and function, and is one of the effective distal tibial limb salvage methods.
Objective To design a novel stentless porcine aortic bioprosthesis and test the feasibility and its function in vitro after the valve was implanted by a modified method. Methods Six stentless porcine aortic bioprosthesis were divided into two groups according to different implantation, single layer suture group: new improvement stentless porcine aortic bioprosthesis sutured with single layer was implanted; double layer suture group: stentless porcine aortic bioprosthesis developmented by our laboratory used double layer suture was implanted. Each group contained three scales: 23 mm ,25 mm and 27 mm. Analogue ex vivo aortic valve replacement was performed , the feasibility of the new implantation was detected. Effective orifice area, transvalvular pressure gradient and regurgitation ratio were recorded at the cardiac output of 2.0 L/min, 3.5 L/min, 5.0 L/min and 7.0 L/min under the guideline of International Organization for tandardization (ISO)5840. Results The average aortic valve implantation time used for single layer suture and tradition double layer suture were 50 min and 70 min respectively. The transvalvular pressure gradient in the single layer suture group were significantly lower than those in double layer suture group under the flow of 5.0 L/min in 23 mm valve and 27 mm valve (13.51±0.51 mm Hg vs. 14.44±0.99 mm Hg, 7.36±0.19 mm Hg vs. 7.53±0.28 mm Hg;P<0.01);and the effective orifice area in the single layer suture group were larger than those in double layer suture group in the same case(1.87±0.06 cm2 vs. 1.76±0.08 cm2, 2.26±0.07 cm2 vs. 2.16±0.05 cm2;P<0.01). There was no statistically difference in other parameters between both groups. Conclusion The novel design of new improvement stentless porcine aortic bioprosthesis used single layer suture has good hemodynamic characteristics as the nature structure . The modified suture method decrease the implantation time.Nemerical data of the evaluation in vitro show that the difference between single layer suture group and double layer suture group in effective orifice area,transvalvular pressure gradient and regurgitation ratio haveno statistical significance. This experiment is the foundation of the animal and clinical experiment in the future.
Objective To compare the short-term result between the high-flex (HF) and conventional posteriorstabil ized (PS) prosthesis in total knee arthroplasty (TKA). Methods From April 2005 to October 2007, 23 cases (27 knees) underwent TKA by HF prosthesis (HF group), and 35 cases (41 knees) underwent TKA by PS prosthesis (PS group).In HF group, there were 2 males (3 knees) and 21 females (24 knees) aged (64.3 ± 5.6) years, including 20 cases (23 knees) of osteoarthritis and 3 cases (4 knees) of rheumatoid arthritis; body mass index (BMI) was 27.3 ± 3.9; the course of disease was (5.3 ± 5.6) years; the Hospital for Special Surgery Scoring System (HSS) score was 58.4 ± 7.9; the Western Ontario and McMaster universities osteoarthritis index (WOMAC) score was 49.4 ± 6.9; the maximum knee flex degree was (107.6 ± 8.3)°; and the range of knee motion was (103.5 ± 7.7)°. In PS group, there were 3 males (3 knees) and 32 females (38 knees) aged (65.1 ± 5.9) years, including 33 cases (39 knees) of osteoarthritis and 2 cases (2 knees) of rheumatoid arthritis; BMI was 27.1 ± 4.1; the course of disease was (5.1 ± 4.9) years; HSS score was 60.1 ± 10.4; WOMAC score was 47.9 ± 7.2; the maximum knee flex degree was (108.4 ± 9.7)°; and the range of knee motion was (105.9 ± 11.4)°. There were no significant differences in general data between two groups (P gt; 0.05). Results All incisions achieved heal ing by first intention. No compl ication of ankylosis, blood vessel and nerve injuries, and prosthesis loosening occurred. All patients were followed up for 24-54 months (average 32.8 months). There were no significant differences in the HSS score, WOMAC score, the maximum knee flex degrees, and the range of knee motion at 3, 12, and 24 months after operation between two groups (P gt; 0.05), but there were significant differencesbetween pre- and post-operation (P lt; 0.05). Anterior knee pain occurred in 1 case of HF group and 4 cases of PS group after 24 months, the incidence rates were 3.70% in HF group and 9.76% in PS group, showing significant difference (P lt; 0.05). The X-ray films showed that no lucent zone around prosthesis and no patella baja were observed, and the force l ine was excellent. Conclusion There is no significant difference in the range of knee motion and cl inical scores between the HF prosthesis and the PS prosthesis, but the former’s incidence rate of anterior knee pain is lower.
Objective To compare the difference of anterior knee pain between mobile-bearing prosthesis and fixedbearing prosthesis after total knee arthroplasty (TKA). Methods Between January 2008 and October 2008, 72 patients withosteoarthritis were treated with primary TKA. All patients were randomly divided into fixed-bearing prosthesis group (n=37)and mobile-bearing prosthesis group (n=35). In fixed-bearing prosthesis group, there were 8 males and 29 females with an average age of 69.6 years (range, 57-76 years), weighing from 55 to 92 kg (mean, 66.7 kg); the locations were the left knee in 20 cases and the right knee in 17 cases; the body mass index (BMI) ranged from 17.6 to 37.3 (mean, 26.2); the disease duration was 3-22 years; the Knee Society Score (KSS) knee score, function score, patellar score, and pain score were 29.4 ± 15.3, 33.4 ± 16.8, 7.2 ± 2.5, and 2.5 ± 2.2, respectively; and the Insall-Salvati (I-S) index was 1.6 ± 0.3. In mobile-bearing prosthesis group, there were 9 males and 26 females with an average age of 68.2 years (range, 58-73 years), weighing from 50 to 86 kg (mean, 67.9 kg); the locations were the left knee in 30 cases and the right knee in 5 cases; the BMI ranged from 18.4 to 34.4 (mean, 25.6); the disease duration was 6-18 years; the KSS knee score, function score, patellar score, and pain score were 30.9 ± 14.7, 31.4 ± 14.4, 6.8 ± 3.1, and 2.0 ± 2.3, respectively; and the I-S index was 1.6 ± 0.2. There was no significant difference in general data between 2 groups (P gt; 0.05). Results All incisions healed by first intention; no deep vein thrombosis of lower l imbs or pulmonary embol ism occurred. All patients were followed up 12-16 months. In mobile-bearing prosthesis group, knee infection occurred in 1 case, dislocation of the knee in 1 case, and cl icking of the knee in 3 cases; in fixed-bearing prosthesis group, cl icking of the knee occurred in 1 case. There was no significant difference in KSS knee score, function score, patellar score, or pain score between 2 groups (P lt; 0.05) at last follow-up; and there was no significant difference in congruence angle, lateral patellofemoralangle, patellar tilt angle, lateral patellar displacement, patellar displacement, or I-S index between 2 groups at last follow-up (P gt; 0.05). Anterior knee pain occurred in 7 cases (18.9%) of the fixed-bearing prosthesis group and in 5 cases (14.3%) of the mobilebearing prosthesis group, showing no significant difference (χ2=0.227, P =0.634). There were significant differences in KSS knee score, function score, patellar score, and I-S index between patients with anterior knee pain and patients without anterior knee pain (P lt; 0.05). Conclusion Fixed-bearing prosthesis and mobile-bearing prosthesis have the same short-term effectiveness and the incidence of anterior knee pain.
ObjectiveTo review research progress on the design, manufacturing, and clinical application of three-dimensional (3D) printed customized prosthesis in acetabular reconstruction of hip revision surgery. MethodsThe related research literature on 3D printed customized prosthesis and its application in acetabular reconstruction of hip revision surgery was searched by key words of “3D printed customized prosthesis”, “revision hip arthroplasty”, “acetabular bone defect”, and “acetabular reconstruction” between January 2013 and May 2024 in Chinese and English databases, such as CNKI, Wanfang database, PubMed, etc. A total of 34 271 articles were included. After reading the literature titles, abstracts, or full texts, the literature of unrelated, repetitive, low-quality, and low evidence level was screened out, and a total of 48 articles were finally included for analysis and summary. ResultsThe bone growth and mechanical properties of 3D printed customized prosthesis materials are better than those of non-3D printed customized prosthesis, which further solves the problem of elastic modulus mismatch between the implant and natural bone caused by “stress shielding”; the porous structure and antibacterial coating on the surface of 3D printed customized prosthesis have good anti-bacterial effect. 3D printed customized prosthesis can perfectly match the patient’s individual acetabular anatomical characteristics and defect type, thus improving the accuracy of acetabular reconstruction and reducing the surgical time and trauma. Conclusion3D printed customized prosthesis can be used for precise and efficient individualized acetabular reconstruction in hip revision surgery with good early- and mid-term effectiveness. More optimized production technics and procedures need to be developed to improve the efficiency of clinical application and long-term effectiveness.
Objective To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. MethodsBetween February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening. Results The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision (P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation (P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant (P<0.05). There was no significant difference in the difference of weight arm among three time points (P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred. Conclusion Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.
Objective To review targeted muscle reinnervation (TMR) surgery for the construction of intelligent prosthetic human-machine interface, thus providing a new clinical intervention paradigm for the functional reconstruction of residual limbs in amputees. MethodsExtensively consulted relevant literature domestically and abroad and systematically expounded the surgical requirements of intelligent prosthetics, TMR operation plan, target population, prognosis, as well as the development and future of TMR. Results TMR facilitates intuitive control of intelligent prostheses in amputees by reconstructing the “brain-spinal cord-peripheral nerve-skeletal muscle” neurotransmission pathway and increasing the surface electromyographic signals required for pattern recognition. TMR surgery for different purposes is suitable for different target populations. Conclusion TMR surgery has been certified abroad as a transformative technology for improving prosthetic manipulation, and is expected to become a new clinical paradigm for 2 million amputees in China.
Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.