Objective To explore the effectiveness of reduction robot combined with navigation robot-assisted minimally invasive treatment for Tile type B pelvic fractures. Methods Between January 2022 and February 2023, 10 patients with Tile type B pelvic fractures were admitted. There were 6 males and 4 females with an average age of 45.5 years (range, 30-71 years). The fractures were caused by traffic accident in 5 cases, bruising by heavy object in 3 cases, and falling from height in 2 cases. The interval between injury and operation ranged from 4-13 days (mean, 6.8 days). There were 2 cases of Tile type B1 fractures, 1 case of Tile type B2 fracture, and 7 cases of Tile type B3 fractures. After closed reduction under assistance of reduction robot, the anterior ring was fixed with percutaneous screws with or without internal fixator, and the posterior ring was fixed with sacroiliac joint screws under assistance of navigation robot. The time of fracture reduction assisted by the reduction robot was recorded and the quality of fracture reduction was evaluated according to the Matta scoring criteria. The operation time, intraoperative fluoroscopy frequency and time, intraoperative bleeding volume, and incidence of complications were also recorded. During follow-up, the X-ray film of pelvis was taken to review the fracture healing, and the Majeed score was used to evaluate hip joint function. Results The time of fracture reduction was 42-62 minutes (mean, 52.3 minutes). The quality of fracture reduction according to the Matta scoring criteria was rated as excellent in 4 cases, good in 5 cases, and poor in 1 case, with excellent and good rate of 90%. The operation time was 180-235 minutes (mean, 215.5 minutes). Intraoperative fluoroscopy was performed 18-66 times (mean, 31.8 times). Intraoperative fluoroscopy time was 16-59 seconds (mean, 28.6 seconds). The intraoperative bleeding volume was 50-200 mL (range, 110.0 mL). No significant vascular or nerve injury occurred during operation. All patients were followed up 13-18 months (mean, 16 months). X-ray films showed that all fractures healed with the healing time of 11-14 weeks (mean, 12.3 weeks). One case of ectopic ossification occurred during follow-up. At last follow-up, the Majeed score was 70-92 (mean, 72.7), and the hip joint function was rated as excellent in 2 cases and good in 8 cases, with the excellent and good rate of 100%. Conclusion The reduction robot combined with navigation robot-assisted minimally invasive treatment for Tile type B pelvic fractures has the characteristics of intelligence, high safety, convenient operation, and minimally invasive treatment, which can achieve reliable effectiveness.
ObjectiveTo investigate the effectiveness of anterior subcutaneous internal fixator combined with posterior plate in the treatment of unstable pelvic fractures.MethodsBetween January 2015 and January 2019, 26 cases of unstable pelvic fractures were treated with anterior subcutaneous internal fixator combined with posterior plate. There were 16 males and 10 females, with an average age of 42.8 years (range, 25-66 years). According to the Tile classification, 9 of them belonged to type B2, 6 to type B3, 7 to type C1, 3 to type C2, 1 to type C3. The injury severity score (ISS) was 6-43 (mean, 18.3). Four cases combined with brain injury, 7 with limb fractures, 3 with hemopneumothorax, 1 with sciatic nerve injury. The time from injury to operation was 4-12 days (mean, 6.4 days). The intraoperative blood loss, operation time, and the complications were recorded. The fracture reduction and the postoperative function of patients were evaluated.ResultsAll patients were followed up 12-26 months (mean, 16.8 months). The operation time was 65-142 minutes (mean, 72.5 minutes) and the intraoperative blood loss was 42-124 mL (mean, 64.2 mL). There were 2 cases of unilateral lateral femoral cutaneous nerve stimulation, 1 case of femoral nerve paralysis, and 1 case of superficial infection of incision, which were cured after corresponding treatment. X-ray films showed that all fractures healed at 3 months after operation. At last follow-up, according to Matta criteria for fracture reduction, the results were excellent in 8 cases, good in 15 cases, fair in 2 cases, and poor in 1 case, with an excellent and good rate of 88.5%. According to Majeed scoring system for pelvic function, the results were excellent in 10 cases, good in 12 cases, and fair in 4 cases, with an excellent and good rate of 84.6%.ConclusionFor unstable pelvic fractures, the anterior subcutaneous internal fixator combined with posterior plate has fewer operative complications, high security, and achieve good effectiveness.
Objective To define a safe distance range from the LC-Ⅱ screw trajectory to the apex of the greater sciatic notch based on pelvic CT measurements, and to clinically assess the feasibility of using this range under iliac oblique view combined with iliac tangential view fluoroscopy to guide screw insertion. Methods CT scans of 104 normal pelvises collected between January 2022 and February 2025 were analyzed. There were 52 males and 52 females, with a median age of 45.8 years (range, 19-76 years). The RadiAnt DICOM Viewer software was used to reconstruct coronal, sagittal, and axial sections of the potential LC-Ⅱ screw trajectory. The maximum safety distance (Dmax) and the optimal safety distance (Dopt) from this trajectory to the greater sciatic notch were measured on the coronal and sagittal views. A retrospective analysis was conducted on 21 patients with LC-Ⅱ type pelvic fractures treated with the LC-Ⅱ screws fixation. And the screws were placed within the pre-defined safe distance under guidance from the iliac oblique view and iliac tangential view. Postoperative CT scans were obtained to evaluate the accuracy of screw placement. Results Radiographic measurements from the 104 cases showed that Dmax ranged from 1.87 to 3.87 cm (mean, 2.79 cm), and Dopt ranged from 1.01 to 2.92 cm (mean, 1.84 cm). Both Dmax and Dopt were significantly greater in the males than in the females (P>0.05). No significant difference was found between the left and right sides within the same gender (P>0.05). All 21 patients successfully underwent fracture reduction and fixation, with a total of 23 LC-Ⅱscrews implanted. According to the Lonstein grading system, the screw placement accuracy was rated as excellent in 16 screws, good in 3, fair in 3, and poor in 1, with an excellent and good rate of 82.6%. ConclusionUtilizing a CT-defined safe distance range from the screw trajectory to the greater sciatic notch, and adhering to this range under iliac oblique view combined with iliac tangential view fluoroscopy, enables the accurate and precise placement of LC-Ⅱ screws.
Objective To compare the reduction qualities of three-dimensional visible technique without fluoroscopy and two-dimensional fluoroscopy for unstable pelvic fractures during operations. Methods The clinical data of 40 patients with unstable pelvic fractures, who met the selection criteria in three clinical centers between June 2021 and September 2022, were retrospectively analyzed. According to the reduction methods, the patients were divided into two groups. Twenty patients in trial group were treated with unlocking closed reduction system combined with three-dimensional visible technique without fluoroscopy; 20 patients in control group with unlocking closed reduction system under two-dimensional fluoroscopy. There was no significant difference in the gender, age, injury mechanism, Tile type of fracture, Injury Severity Score (ISS), and the time between injury to operation between the two groups (P>0.05). The qualities of fracture reduction according to the Matta criteria, operative time, intraoperative blood loss, fracture reduction time, times of fluoroscopy, and System Usability Scale (SUS) score were recorded and compared. Results All operations were successfully completed in both groups. According to the Matta criteria, the qualities of fracture reduction were rated as excellent in 19 patients (95%) in trial group, which was better than that in the control group (13 cases, 65%), with a significant difference (χ2=3.906, P=0.048). The operative time and intraoperative blood loss had no significant differences between the two groups (P>0.05). The fracture reduction time and times of fluoroscopy were significantly less in trial group than in control group (P<0.05), and SUS score in trial group was significantly higher in trial group than in control group (P<0.05). ConclusionCompared to using unlocking closed reduction system under two-dimensional fluoroscopy, three-dimensional visible technique without fluoroscopy can significantly improve the reduction quality of unstable pelvic fractures without prolonging the operative time, and is valuable to reduce iatrogenic radiation exposure for patients and medical workers.
Pelvic fractures are often caused by high-energy trauma. The condition of patients is complex and requires active therapy. The treatment of pelvic fractures includes conservative and surgical treatment. Surgical treatment is suitable for patients with unstable pelvic fractures. In recent years,the anterior subcutaneous internal fixator (INFIX) for the treatment of unstable pelvic fractures has been popularized and achieved extraordinary outcomes. INFIX is a relatively novel technology for the treatment of anterior pelvic ring fractures. It has excellent biomechanical properties, a wide range of indications, and has the advantages of minimally invasive, convenient care, fewer complications, and better clinical outcomes. If patients with anterior pelvic ring fractures have the indications for INFIX after careful evaluation, INFIX is recommended. This article summarizes the research progress of INFIX in the treatment of anterior pelvic ring fractures, and summarizes its surgical methods, biomechanical properties, indications, advantages, complications and clinical outcomes.
ObjectiveTo introduce the experience of intelligent monitoring system assisted pelvic fracture closed reduction to treat complex pelvic fracture in a minimally invasive method.MethodsA 30-year-old male patient with complex pelvic fracture caused by a falling injury was treated in December 2019. The pelvic fracture was diagnosed by X-ray film and CT three-dimensional reconstruction. The AO/Orthopaedic Trauma Association (AO/OTA) classification was 61-C3.3 type (H-shaped sacrum fracture with pubic symphysis separation). At 48 hours after injury, the vital signs were stable, and the operation was performed. The pelvic fracture was reduced with the help of pelvic reduction frame and skeletal traction, the intelligent monitoring system, and fixed with the channel screws.ResultsThe intraoperative blood loss was 50 mL, the operation time was 180 minutes, and the fluoroscopy time was 45 seconds. The incision healed well after operation. The X-ray film of pelvis was taken on the next day after operation, and the fracture reduction was evaluated as anatomical reduction according to Matta standard; CT three-dimensional reconstruction showed that the fixation screws were all located in the cortex of bone, without penetrating the cortex of bone.ConclusionThe intelligent monitoring system assisted pelvic fracture closed reduction is reliable in the minimally invasive treatment of complex pelvic fractures, which can achieve good results and reduce intraoperative fluoroscopy.
Objective To explore the choice for the internal fixation in treatment of pelvic posterior lesions. Methods From May 2000 to June 2005, the treatment was given to 40 patients (28 males, 12 females,aged 21-58 years) with pelvic posterior ring fracture and dislocation. Of the patients, 23 had a traffic accident, 11 had a crush injury and 6 had a fall. As for the state of an injury to the pelvic posterior ring, 22 patients had disloation of the sacroiliac joint, 12 had a sacrum fracture dislocation, and 6 had an ala iliac fracture and disloation of the sacroiliac joint. According to the Denis(1988) classification, fracture of the (sacral region Ⅰ was found in 6 cases, fracture of the scaral) region Ⅱ in 3 cases, and fracture of the scaral region Ⅲ in 3 cases. As for the complication of the pelvic front ring fracture:separation of the symphysis pubis was found in 14 cases, fraclure of the superior ramus and inferior ramus of the pubis on one side in 10 cases. The two-side superior ramus of publis and inferion ramus of pubisin 8 cases, homopleural acetabular fracture on one side in 4 cases, acetabularfracture on one side and contralateral superior ramus and inferior ramus fracture of the pubis in 3 cases, and acetabular fracture on the opposite side in 1 case.As for the operation, 28 patients underwent the stillplate internal fixation of the sacroiliac joint from anterior at 24 h to 15 days after the injury, 2 underwent the screwinternal fixation of the sacroiliac joint from posterior, and remaining 10 underwent the internal fixation by the Galveston Technique associated with the ISOLAsystem. The therapeutic results were analyzed. Results The followup of the 40 patients for 6 months to 3 years revealed that before operation 3 had a sacral plexus nerve injury, and after operation 1 patient developed perineum numbness and urinary incontinence, 1 developed claudication,3 developed posterior urethral fragmentation, and 2 developed urinary bladderrupture; however, they had a complete recovery after the reparative surgery. Conclusion In treatment of the pelvic posterior ring lesions,an appropriate internal fixation can be chosen according to the type of the pelvic fracture,applicability of internal fixation, condition of the patient,equipment available, and the doctor’s experience.
Objective To investigate the clinical characteristics of unstable pelvic fractures and to find out an alternative for the treatment. Methods From October 2000 to June 2004, fifty-six patients with unstable pelvic fractures were treated by open reduction and pelvic-reconstructed plate fixation to recover the anatomical structure of pelvis and acetabulum. According to Tile classification, 33 cases were type B (15 cases were Tile B1, 11 cases were Tile B2, 7 cases were Tile B3); 23 cases were type C (10 cases were Tile C1, 8 cases were Tile C2, 5 cases were Tile C3). Results The 56 cases were followed up 12 to 68 months(26 months in average).All cases with fractures got healed during 3 to 6 mouths. According to the Majeed evaluation, 40 cases were excellent, 11 cases were good, 4 cases were fair, and only one case was a failure. The rate of excellency and goodness was 91.07%.The pelvic abnormity was rectified; partial patients felt light pain in iliac scar. Conclusion The choice of the proper operative approach and pelvic-reconstructed plate fixation by allowingfor fracture classification is a good and dependable means for treating unstablepelvic fractures.
ObjectiveTo assess the effectiveness of anterior subcutaneous internal fixation (INFIX) combined with posterior percutaneous iliosacral screw for the treatment of unstable pelvic fractures.MethodsBetween August 2016 and November 2017, 19 cases of unstable pelvic fractures were treated with anterior subcutaneous INFIX combined with posterior percutaneous iliosacral screw. There were 14 males and 5 females, with an average age of 40.6 years (range, 17-69 years). Causes of injury included traffic accident injury in 11 cases, falling from height in 5 cases, bruise injury by heavy object in 3 cases. According to Tile classification, there were 2 cases of type B1, 6 cases of type B2, and 11 cases of type C. Anterior ring injuries included bilateral pubic ischial ramus fractures in 12 cases, unilateral pubic ischial ramus fractures in 5 cases, and symphysis pubis separation in 2 cases. Posterior ring injuries included sacroiliac ligament injuries in 2 cases, unilateral iliac bone fractures in 3 cases, unilateral sacral fractures in 11 cases, unilateral sacroiliac joint dislocation in 2 cases, and bilateral sacral fracture in 1 case. The intraoperative blood loss and operation time were recorded, and the fracture healing and postoperative complications were observed. Matta score was used to evaluate the reduction of fracture, and Majeed score was used to evaluate the postoperative function of patients.ResultsThe operation time was 47-123 minutes (mean, 61.4 minutes) and the intraoperative blood loss was 50-115 mL (mean, 61.1 mL). One case had superficial infection at the site of screw implantation, and 1 case had unilateral cutaneous nerve stimulation, which were cured after corresponding treatment. There was no damage of urinary system, reproductive system, and intestine. All cases were followed up 12-25 months (mean, 18.1 months). All the fractures healed after operation, the average healing time was 9.5 weeks (range, 8-13 weeks); no nonunion, delayed healing, internal fixation loosening, fracture, and other situations occurred. Of the 2 patients with lumbosacral plexus injury before operation, 1 recovered completely and 1 had residual mild claudication. At last follow-up, the reduction of fracture was evaluated by Matta scoring standard, the results were excellent in 13 cases and good in 6 cases, with an excellent and good rate of 100%; the function was evaluated by Majeed scoring standard, the results were excellent in 15 cases and good in 4 cases, with an excellent and good rate of 100%.ConclusionMinimally invasive pelvic stabilization by using anterior subcutaneous INFIX and posterior percutaneous iliosacral screw for treatment of unstable pelvic fractures, can achieve good fracture reduction and definitive stabilization with minimum complications and obtain excellent functional outcomes.
Objective To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as “computer navigation system”) in the treatment of posterior pelvic ring injuries. MethodsA retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups (P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard. ResultsThe operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group (P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant (P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group (P<0.05). ConclusionCompared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.