• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Cervical vertebra" 24 results
        • BIOMECHANICAL RESEARCH ON MORPHOMETRIC CHANGES IN ADJACENT INFERIOR CERVICAL INTERVERTEBRAL FORAMEN AFTER ARTIFICIAL DISC REPLACEMENT

          Objective To explore changes in the height and width of the cervical intervertebral foramina of C6,7 before and after the C5,6 discetomy, the replacement or the anterior intervertebral fusion so as to provide the theoretical basis for the clinical practice. Methods Eleven fresh cervical spinal specimenswere obtained from young adult cadavers. The specimens of C5,6 were divided into the integrity group, the discectomy group, the artificial disc replacement group, and the intervertebral fusion group. The range of variety (ROV) of the C6,7 intervertebral foramen dimensions (height, width) before and after the loading tests (0.75, 1.50 Nm) were measured in the 4 groups. Results The C6,7 intervetebral foramen height and width increased significantly during flexion (Plt;0.01) but decreased significantly during extension (Plt;0.01). There was a significantdifference between the two test conditions in each of the 4 groups (Plt;0.01). However, in the two test conditions there was no significant difference in ROV of the C6,7 intervetebral foramen height and width during flexion and extension betweenthe integrity group, the discectomy, and the artificial disc replacement group(Pgt;0.05), but a significant difference in the above changes existed in the intervertebral fusion group when compared with the other 3 groups (Plt;0.05). In the same group and under the same conditions, the ROV of the C6,7 intervetebral foramen height and width was significantly different in the two test conditions (Plt;0.01). Conclusion The results have indicated thatartificial disc replacement can meet the requirements of the normal cervical vitodynamics. The adjacent inferior cervical intervetebral foramen increases during flexion but decreases during extension. The intervertebral fusion is probably one of the causes for the cervical degeneration or the accelerated degeneration and for the cervical spondylotic radiculopathy and the brachial plexus compression.

          Release date:2016-09-01 09:20 Export PDF Favorites Scan
        • COMPARING LOSS OF ANTERIOR COLUMN HEIGHT AND CERVICAL COBB ANGLE WITH THREE DIFFERENT TYPES OF ANTERIOR CERVICAL DISCECTOMY AND FUSION

          Objective To compare the loss of anterior column heightand cervical Cobb angle with three different types of anterior cervical discectomy and fusion(ACDF). Methods A prospective randomized study was performed on 60 patients who had undergone ACDF with the autologous iliac crest graft (group A, n=20), the autogenous bone and the anterior cervical locking plates (group B, n=20), and Syncage-C filled with the local autograft reamings (group C, n=20) from January 1998 to January 2003. The patients diagnosed as having cervical radiculopathy (RP) and cervical spondylotic myelopathy (CSM) were indicated for ACDF. Of the patients, 41 were male and 19 female with a mean age of 57 years (range, 36-68) and their average course of disease was 6.2 months (range, 1-36). There were 36 one-level and 24 two-level fusions from C3,4 to C7,T1. Radiological measurements were performed on the cervical radiographs taken before operation, 7 days and 3 months after operation, and on the last day of the follow-up; then, the height and Cobb angle of the fused segment, functional restoration, and clinical outcome were evaluated in the three groups. Results The followup of more than 2 years (range,2-7) showed that the average loss of anterior column height and Cobb angle of the fused segments in groups A and B, which had not preserved the-endplate, hada greater increase than that in group C, which had preserved the endplate. Of the patients, 12 had autograft collapse, 3 autograft displacement, and 10 postural abnormality between the fused segments, most of which happened in groups A andB. The fusion rate was 93.3% (56 cases) according the strict arthrodesis critera; their excellent and good rate in the functional assessment was 83.3% (RP 90.4%, CSM 79.5%); the overall satisfactory (excellent and good) rates in groups A,B and C were 75%, 85% and 90%, respectively. Conclusion To increase the resistance to graft subsidence, which is a major reason for narrowness of the fused segments, and to maintain normal cervical curvature, we should improve our skills of bone grafting performance, preserve the endplate, carefully evaluate the degree of osteoporosis before operation, and use anterior cervical locking plate and /or fusion with Syncage-C when necessary.

          Release date:2016-09-01 09:25 Export PDF Favorites Scan
        • EFFECT OF MODIFIED UNILATERALLY-OPEN EXPANSIVE LAMINOPLASTY USING BRIDGE GRAFTING AND RESTRUCTING POSTERIOR LIGAMENTOUS COMPLEX METHODS ON AXIAL SYMPTOMS AND CERVICAL CURVATURE CHANGE

          Objective To explore if the modified unilaterally-open expansive laminoplasty using bridge grafting and reconstructing posterior ligamentous complex methods is effective in preventing persisting axial symptoms, restriction of neck motion, and loss of cervical curvature. Methods From June 2000 to October 2005, 138 patients with cervical spondylotic myelopathy underwent this procedure. Of them, 78 who were followed for more than 2 years (group A) were included in this study. Another 69 patients who underwent conventional unilaterally opendoor laminoplasty served as controls(groupB). The JOA scores and the incidence of newly developed or deteriorated axial symptoms were recorded. Preoperative and postoperative ranges of neck motion were measured on lateral flexion and extension radiographs. Preoperative and postoperative cervical curvature indices were calculated according to Ishihara’s method. Results The patients of group A were followed 24-44 months (mean 33 months), and the patients of group B were followed 2453 months(mean 35 months). The operative time was 114±20 min in group A and 70±25 min in group B,showing statistically significant difference(P<0.05). The operative blood loss was 280±72 ml in group A and 210±80 ml in group B(P>0.05). Accordingto JOA scoring, the average recovery rates were 67.0%±17.3% in group A and 65.0%±21.4% in group B(P>0.05). Postoperative development or deterioration of axial symptoms occurred in 12% of patients in group A and 51% of patients in group B, showing statistically significant difference(P<0.05). Postoperative range of neck motion was 88.0%±10.1% of the preoperative one in group A and 64.0%±16.3% in group B(P<0.05). There was no significant difference between preoperative(15.3±8.2) and postoperative(13.5±9.3) cervical curvature index in group A, whereas the mean value of postoperative index (11.1±5.7) was significantly smaller than that of preoperative one (17.2±13.5) in group B (Plt;0.05). Conclusion This new procedure was less invasive to the posterior extensor mechanism than the conventional unilaterally-open laminoplasty and was effective in preventing postoperative morbidities.

          Release date:2016-09-01 09:22 Export PDF Favorites Scan
        • COMPARISON OF RESTORING AND MAINTAINING THE CERVICAL CURVATURE AND HEIGHT BY USING THREE DIFFERENT ANTERIOR CERVICAL PLATE SYSTEMS

          Objective To investigate and compare the effects of restoring and maintaining the cervical curvature and height of the fused segment by using three different anterior cervical plate systems. Methods From January 2002 to June 2004, 122 patients underwent anterior cervical decompression,autogenous iliac bone graft and plate fixation. Of the 122 patients (85 males, 37 females, aged 14-70), 37 underwent surgery involving the fixation with the Orion plate system, 39 with the Zephir plate system, and 46 with the Codman platesystem. The cervical curvature and height of the fused segment were measured onthe lateral X-ray films so as to compare the changes of the conditions preoperatively,1 week after surgery, and during the follow-up, and also to compare the difference among the three groups. Results The follow-up of the patients for 6-35 months (average 17.3 months) showed that all the patients developed the bone fusion 6 months after operation. There was a significant improvement in the cervical curvature and height of the fused segment before operation versus 1 week after operation(Plt;0.05); however, there were no significant changes 1 week after operation versus during the followup in each group(Pgt;0.05); there was no significant difference among the three groups(Pgt;0.05). Conclusion The three plate systems can effectively reconstruct and maintain the cervical curvature and height of the fused segment, with a satisfactory effect in a short term.

          Release date:2016-09-01 09:25 Export PDF Favorites Scan
        • SURGICAL TREATMENT OF FRACTURE-DISLOCATION OF CONNECT OF CERVICAL VERTEBRAE AND THORACIC VERTEBRAE

          OBJECTIVE: To discuss the value of anterior operation in fracture-dislocation of connect of cervical vertebrae and thoracic vertebrae. METHODS: From 1997, 21 patients with fracture-dislocation of connect of cervical vertebra and thoracic vertebrae were operated on. The interval between injury and operation was within 24 hours in 4 cases, 2-7 days in 9 cases, 8-14 days in 3 cases and within 4 weeks in 5 cases. The locations were C6,7 in 7 cases, C7 in 9 cases and T1 in 5 cases. The nerves function of spinal of all the cases have different degrees of injury. Classification of Frankel were the following: 3 cases of grade A, 6 cases of grade B, 9 cases of grade C, and 3 cases of grade D. The operative procedure included the following: anterior operation of cervical vertebrae; incision of most fracture vertebral body to decompress; transplantation of ilium bone grafting fusion; and internal fixation of anterior cervical vertebrae with locking-steel. RESULTS: In 21 patients, 1 died of accompanying by pulmonary infection; 20 were followed up 8 months to 3 years with an average of 21 months. All transplanted ilium had fused. The nerve function of spinal cord had recovered in different degrees(2 cases of grade A, 1 case of grade C, 9 cases of grade D and 8 cases of grade E); the turn of vertebral column was normal. No internal fixation failed. CONCLUSION: Anterior operation is a better way to treat fracture-dislocation of connect of cervical vertebrae and thoracic vertebrae with easy operation, less complications, satisfactory reduction of fracture and good stability.

          Release date:2016-09-01 09:35 Export PDF Favorites Scan
        • CLINICAL OBSERVATION ABOUT PERCUTANEOUS VERTEBROPLASTY FOR OSTEOLYTIC METASTATIC CARCINOMA OF CERVICAL VERTEBRA

          Objective To investigate the feasibil ity, safety and operative techniques of percutaneous vertebroplasty (PVP) in treating osteolytic bone metastasis of cervical vertebra and reconstructing the function of cervical vertebra. Methods From March 2005 to December 2007, 10 patients with osteolytic bone metastatic carcinoma in single cervical vertebral body received PVP, including 5 males and 5 females aged 38-75 years (mean 54.5 years). Among them, 5 patients had primary lung tumor, 1 primary renal tumor, 1 primary breast tumor, 1 primary cervical tumor and 2 unknown primary lesion. The course of disease was 2-4 years. All the patients suffered from obviously cervical pain and l imitation of activity, including 4 cases of metastatic tumor of the C2 vertebral body, 2 of C3, 2 of C6 and 2 of C7. The general condition of patients was stable before operation, and no blood coagulation dysfunction, radiculalgia and spinal cord compression were detected. Lateral PVP was performed on 6 cases, approaching between the vertebral artery and the carotid sheath under CT guidance and anterolateral PVP was performed on the rest 4 cases, approaching between the trachea and the internal carotid artery under continuously X-ray fluoroscopy. The amount of bone cement injected was 3-4 mL, and the fill ing rate was 50%-100%. Results Without obvious bleeding or organ injury, the puncture was performed successfully on all the patients. Without symptom of spinal cord compression, patients suffered from pain during operation (1 case) and such compl ications noted by immediate CT or X-rays examination after operation as paravertebral epidural cement leakage (2 ases),transverse foramen cement leakage (1 case) and pinhole reflux (3 cases). The pain of patients was improved to various degree postoperatively, the visual analogue scales score was (5.9 ± 1.2) points before operation, which was changed to (2.6 ± 1.2) points at 1 hour after PVP and (1.6 ± 1.3) points at 1 week after PVP, indicating there was a significant difference between pre- and postoperation (P lt; 0.05). During the regular follow-up at 1 week, 3 and 12 months after PVP, all patients had no dislocation of cervical vertebra body, spinal cord compression and paralysis. Five patients died from multiple organ failure due to primary tumor progression, including 3 cases at 6 months after PVP and 2 at 12 months after PVP, and the rest 5 patients’ cervical pain were under control, with sound functional recovery. Conclusion PVP can rel ieve pain quickly and reinforce the stabil ity of the vertebral body, and has sl ight compl ications; the lateral approach is safe and effective.

          Release date:2016-09-01 09:05 Export PDF Favorites Scan
        • Mid-term follow-up of dynamic cervical implant replacement for the treatment of single-segmental degenerative cervical disc disease

          ObjectiveTo evaluate the mid-term clinical and radiological results of dynamic cervical implant (DCI) arthroplasty for degenerative cervical disc disease in Chinese population.MethodsBetween April 2010 and June 2011, 25 patients with single-segmental degenerative cervical disc disease underwent DCI replacement. Visual Analogue Scale (VAS), Japanese Orthopaedic Association (JOA) scores, Neck Disability Index (NDI) and 36-Item Short Form Health Survey Questionnaires (SF-36) were used for evaluation of neurological function and pain severity, before and after operation, and during follow-up period. Radiographic evaluation included range of motion (ROM) of C2–7, surgical segments and adjacent level, intervertebral height of the surgical segments, migration, subsidence of the implant and heterotopic ossification (HO).ResultsThe mean follow-up period was 72.3 months (ranged from 68 to 78 months). The VAS, JOA, NDI, and SF-36 mental and physical component summaries improved significantly after surgery (P<0.05) and remained stable over the whole observation period. The ROM (flexion/extension) and intervertebral height at the level treated with DCI remained at the first 2 years and partly reduced at the final follow-up. ROM for C2–7 and adjacent levels maintained during the follow-up period. DCI subsidence was observed in 11 segements, and 9 segements appeared heterotopic ossification.ConclusionsClinical efficacy of DCI arthroplasty improves and maintaines during the mid-to-long period of follow-up. HO formation is a common phenomenon, leading a dramatic decrease of ROM at index level and recurrence of neurological symptoms. Rate of implant subsidence and migration is relatively high, leaving a potential risk of symptom at index level and adjacent segment degeneration. It suggests that for patients with degenerative cervical disc disease, total disc replacement or anterior cervical discectomy and fusion is still the first choice instead of DCI arthroplasty.

          Release date:2018-09-25 02:22 Export PDF Favorites Scan
        • PREVENTION AND TREATMENT OF EARLY POSTOPERATIVE COMPLICATIONS OF ANTERIOR CERVICALSPINAL SURGERY

          Objective To study the prevention and management of early compl ications associated with anterior cervical spinal surgery. Methods From November 1998 to December 2006, 363 cases were treated with anterior cervicalsurgery, including 268 males and 95 females aged 17-79 years.In these cases, 224 suffered from cervical spondylosis, 39 from cervical disc herniation, 87 from cervical trauma, 9 from cervical tumor and 4 from cervical tuberculosis. Forty-eight cases with anterior cervical surgery were fused by autogenous il iac bones, 132 cases with anterior cervical surgery were fused by autogenous il iac bones and anterior cervical spine locking plates, and 183 cases with anterior cervical surgery were fused by titanium mesh cage and anterior cervical spine locking plates. Results A total of 282 cases were followed up for 3 months to 5 years with the average of 1 year and 11 months. Twenty-three compl ications associated with surgery were found, with an incidence of 8.16%. Three cases of transient superior laryngeal nerve palsy recovered within 3-7 days after the restriction of l iquid diet and fluid replacement. Two cases of recurrent laryngeal nerve palsy recovered by 3-month pronunciation practice. One case of spinal cord injury was treated with medicine for dehydration and anti-inflammation, and was restored to preoperative muscle power of inferior extremity after 6 months. Two cases of CSF leakage were cured with moderate local compression and meticulous water-tight wound closure. Among the 10 patients with compl ications of internal fixation, one suffering mild dysphagia was reoperated, while the others were treated with cephal-cervico-thorax plaster external fixation and recovered with sol id fusion within 3-18 months. Among the 4 cases with cervical hematoma, 1 died of wrong rescue procedures and 1 was infected. Conclusion Adequate preoperative preparation, thorough understanding of anatomy related to the anterior approach and skilled surgical technique are essential for preventing the early postoperative compl ications of anterior cervical spinal surgery.

          Release date:2016-09-01 09:16 Export PDF Favorites Scan
        • CERVICAL LATERAL MASS PLATE WITH ITS CLINICAL APPLICATION

          Objective To evaluate the fixation technique of using the cervical lateral mass plate in the cervical posterior approach operation. Methods Eight patients in this group were admitted from September 2001 to November 2006. Among the 8 patients, there were 6 males and 2 females, with their ages ranging from 28 to 78 years. Cervical vertebral fracture with dislocation was found in 4 patients, C2 spinal cord injury in 1, C1 fracture in 1, cervical spinal stenosis in 1, and C2-5 spinal cord neurofibroma in 1. Muscle strength 3-4. TheFrankel grading system was usedin 6 patients with traumatic injury. Before operation, Grade C was observed in 2patients,Grade D in 3,and Grade E in 1. All the operations were performed according to requirements of the Margel’s method. We positioned 40 screws in all the patients, including 4 screws at C2,6 screws at C3,12 screws at C4,4 screws at C5,4 screws at C6,2 screws at C7,and 6 screws at T1. Results The followingup for an average of 14.1 months (range,645 months) revealed that there was no malposition of the screws in the patients. One of the 8 patients developed spinal instability in the fixed segment at 3 months after operation. The headchestbrace was applied to the patient for 3 months, and the spinal fusion was achieved. The further followingup to 45 months indicated that there was no instability occurring. The remaining patients recovered to their spinal stability by the spinal fusion. The patients also recovered in their neurological function after operation. The Frankel assessment showed that 1 patient had Grade E, 3 from Grade D to Grade E, 1 from Grade C to Grade D, and 1 from Grade C to Grade E. Conclusion The cervical lateral mass plate fixation can provide the immediate and b segmental immobilization for the good cervical spine stability.

          Release date:2016-09-01 09:20 Export PDF Favorites Scan
        • IN VIVO THREE-DIMENSIONAL TRANSIENT MOTION CHARACTERISTICS OF THE SUBAXIAL CERVICAL SPINE IN HEALTHY ADULTS

          ObjectiveTo observe the in vivo three-dimensional (3-D) transient motion characteristics of the subaxial cervical spine in healthy adults. MethodsSeventeen healthy volunteers without cervical spine related diseases were recruited for this study, including 8 males and 9 females with a mean age of 26 years (range, 23-41 years). The vertebral segment motion of each subject was reconstructed with CT, and Rhinoceros 4.0 solid modeling software were used for 3-D reconstruction model of the subaxial cervical spine. In vivo cervical vertebral motion in flexionextension, left and right bending, left and right rotation was observed with dual fluoroscopic imaging system (DFIS). Coordinate systems were established at the vertebral center of C3-7 to obtain the intervertebral range of motion (ROM) and displacement at C3, 4, C4, 5, C5, 6, and C6, 7. The X-axis pointed to the left along the coronal plane, the Y-axis pointed to the back along the sagittal plane, and the Z-axis perpendicular to the X-Y plane pointed to the head. The ROM along X, Y, and Z axises were represented by rotation in flexion-extension (α), in left-right bending (β), and in left-right twisting (γ) respectively, and the displacement in left-right direction (x), in anterior-posterior direction (y), and in proximaldistal direction (z), respectively. ResultsIn flexion and extension, the displacement in anterior-posterior direction of C6, 7 was significantly less that of other segments (P<0.05), but the displacements in left-right direction and in proximaldistal direction showed no significant difference between segments (P>0.05); the ROM values in flexion-extension of C4, 5 and C5, 6 were significantly larger than those of C3, 4 and C6, 7 (P<0.05), and the ROM value in left-right twisting of C4, 5 was significantly larger than those of C5, 6 and C6, 7 (P<0.05), but the ROM value in left-right bending showed no significant difference between segments (P>0.05). In left and right bending, there was no significant difference in the displacement between other segments (P>0.05) except that the displacement in anterior-posterior direction of C3, 4 was significantly larger than that of C4, 5 (P<0.05), and that the displacement in proximal-distal direction of C6, 7 was significantly less than that of C3, 4 and C4, 5 (P<0.05); no significant difference was shown in the ROM value between segments (P>0.05), except that the ROM value in left-right twisting of C3, 4 was significantly larger than that of C5, 6 and C6, 7 (P<0.05). In left and right rotation, the ROM value in left-right twisting of C3, 4 was significantly larger than that of C4, 5 and C6, 7 (P<0.05), and the displacement and ROM value showed no significant differece between other segments (P>0.05). ConclusionThe intervertebral motions of the cervical spine show different characters at different levels. And the 6-degree-of-freedom data of the cervical vertebrae are obtained, these data may provide new information for the in vivo kinematics of the cervical spine.

          Release date: Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜