• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "CT血管造影" 16 results
        • A comparative study of color Doppler ultrasound and CT angiography for preoperative evaluation of perforator vessels in free posterior interosseous artery flap

          Objective To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps. Methods Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient’s satisfaction with the appearance of the skin flap. Results The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods (P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods (P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture, with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9. Conclusion CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.

          Release date: Export PDF Favorites Scan
        • Evaluation of the diagnostic value of artificial intelligence-based CT-FFR and FAI for coronary artery stenosis

          ObjectiveTo investigate the diagnostic value of CT-derived fractional flow reserve (CT-FFR) and fat attenuation index (FAI) based on artificial intelligence-assisted diagnostic software in coronary artery stenosis. MethodsA retrospective analysis was conducted on patients clinically suspected of coronary artery syndrome who underwent coronary computed tomography angiography at Guangdong Province Traditional Chinese and Western Medicine Hospital between June 2021 and May 2025. Patients were divided into two groups according to scanning protocols: group A underwent conventional retrospective electrocardiography-gated scanning, while group B used Flash_ChestPlin mode. Invasive coronary angiography data served as the gold standard for diagnosing vascular stenosis (stenosis rate<50% defined as negative group, ≥50% with clinical symptoms as positive group). Radiation dose was compared between the two scanning protocols. The diagnostic efficacy of CT-FFR, pericoronary FAI, and transluminal attenuation gradient (TAG) based on artificial intelligence system for coronary stenosis was analyzed, including sensitivity, specificity, and area under the curve (AUC). ResultsA total of 567 vessels from 189 patients were analyzed, including 105 males, 84 females with a mean age of (62.5±12.3) years and a mean body mass index of (24.21±3.5) kg/m2. There were 112 patients in the group A and 77 patients in the group B. The radiation dose in the group B was significantly lower than that in the group A [69.7 (58.1, 84.1) mGy·cm vs. 420.4 (338.6, 514.2) mGy·cm, P<0.001]. Significant differences in FAI and CT-FFR were observed between negative and positive groups under both scanning protocols (P<0.05), while no significant difference existed in TAG (P>0.05). In the group A, the AUC values for diagnosing stenosis were 0.925 for CT-FFR, 0.610 for FAI, and 0.516 for TAG. Corresponding values in the group B were 0.889, 0.677, and 0.548 respectively, with CT-FFR demonstrating optimal diagnostic performance. ConclusionUnder both conventional scanning and Flash scanning, the artificial intelligence-based CT-FFR demonstrates good diagnostic performance for coronary artery stenosis, and the Flash protocol significantly lowers radiation dose, indicating substantial potential for clinical application.

          Release date: Export PDF Favorites Scan
        • LENGTHENED PEDICLE OF RECTUS ABDOMINIS FLAP TO REPAIR DEFECT ON NECK AND CHEST

          ObjectiveTo explore the feasibil ity to repair defect on the neck and chest with the rectus abdominis flap which pedicle is lengthened by measuring the width, thickness, and the intercostal space of the inferior costicartilage using CT angiography (CTA). MethodsThirty cases receiving CTA and three-dimensional reconstruction between July and December 2013 were included in the study. Of 30 cases, 17 were male and 13 were female, aged 44-70 years (mean, 56 years). The width and thickness of the 3rd to 7th costicartilages and the distance of the 3rd to 6th intercostal spaces were measured, and the lengthened pedicle was calculated after the 4th to 7th costicartilage was cut off. Between July 2012 and November 2013, the lengthened pedicle of the rectus abdominis flap was cl inically used to repair the defect on the neck and chest in 4 cases. ResultsThe pedicle of the rectus abdominis flap was about 6 cm in length. When the left 7th, 6th, 5th, and 4th costicartilages were cut off, the average pedicle was lengthened by 4.07, 7.99, 12.50, and 17.48 cm respectively; when the right 7th, 6th, 5th, and 4th costicartilages were cut off, the average pedicle was lengthened by 4.63, 10.82, 16.64, and 22.05 cm respectively. In 4 flaps which were cl inically used to repair defects, 3 flap completely survived, 1 flap had partial necrosis. Three patients were followed up 6 months, and the appearance and texture of the flap were satisfactory; 1 patient failed to be followed up. ConclusionResecting the inferior costicartilage can prolong the pedicle of the rectus abdominis flap, therefore it can be used to repair defect on the upper chest and the neck.

          Release date: Export PDF Favorites Scan
        • Experiences of Endovascular Repair in Treatment for Aortic Dissecting Aneurysm(Report of 15 Cases)

          目的 總結腔內修復術治療主動脈夾層的經驗。方法 選擇2011年7月至2013年1月期間我院住院的胸主動脈夾層患者15例,術前均采用CTA評估,全部行腔內修復術。結果 15例患者采用腔內修復手術全部成功,手術時間95~165min,(120±26) min;失血量30~160mL,(68±34) mL。10例采用經股動脈入路,5例采用經股動脈及肱動脈入路。13例單一破口者各植入支架1枚,手術全部成功。15例患者未發生截癱,無一椎基底動脈缺血癥狀,無下肢缺血改變,無傷口感染及腹股溝區淋巴瘺。2例存在Ⅱ型內漏,未經處理自行閉合。隨訪胸腹主動脈CTA掃描顯示覆膜支架均未移位,未發現植入支架后并發近端夾層者。結論 腔內修復術治療主動脈夾層是一種有效的治療方法,具有安全性高、術后并發癥少、治療效果好等優點。

          Release date:2016-09-08 10:23 Export PDF Favorites Scan
        • Model reconstruction and morphological observation of internal carotid artery siphon and ophthalmic artery in non-arteritic anterior ischemic optic neuropathy patients

          ObjectiveTo observe the morphological characteristics of internal carotid artery (ICA) siphon and ophthalmic artery (OA) in patients with non-arteritic anterior ischemic optic neuropathy (NAION) based on CT angiography (CTA) three-dimensional reconstruction of ICA siphon and OA models. MethodsA retrospective cohort study. From January 2017 to January 2019, 26 patients with 31 eyes (NAION group) who were diagnosed with NAION by ophthalmic examination at Beijing Friendship Hospital, Capital Medical Universitywere included in the study. Among them, there were 11 males with 13 eyes, and 15 females with 18 eyes; the age was 67.52±6.30 years old. Nineteen eyes of 19 non-affected contralateral eyes were selected as the contralateral eye group. Among them, there were 9 males with 9 eyes and 10 females with 10 eyes; the age was 65.95±5.66 years old. Twenty-six eyes of 26 age- and sex-matched subjects with normal fundus examination during the same period were selected as the normal control group. All subjects underwent best corrected visual acuity (BCVA), intraocular pressure, fundus photography and CTA examination. The data obtained from CT scans were reconstructed by 3D model, and the anatomical morphology of ICA siphon was divided into U-shape, V-shape, C-shape and S-shape; the diameter of ICA siphon portion and the diameter at the beginning of OA were measured. One-way analysis of variance was used to compare the diameter of the OA at the beginning of the OA and the diameter of the ICA siphon between the three groups of eyes. ResultsThe diameters at the beginning of OA in the NAION group, the contralateral eye group, and the normal control group were 1.17±0.20, 1.34±0.17, and 1.39±0.15 mm, respectively, and the differences among the three groups were statistically significant (F=12.325, P<0.05); there was no significant difference between the contralateral eye group and the normal control group (P=0.310). In the NAION group, the anatomical morphology of the ICA siphon was U-shaped and V-shaped in 20 (64.52%) and 8 (25.81%) eyes respectively, and S and C-shaped in 3 eyes (9.67%); in the contralateral eye group, in the control group, the ICA siphon shape of the eyes examined was U-shaped and V-shaped, and S-shaped and C-shaped were rare. The diameters of the ICA siphons in the NAION group, the contralateral eye group, and the normal control group were 3.50±0.69, 3.22±0.59, and 3.55±0.54 mm, respectively. There was no significant difference between the three groups (F=1.860, P=0.163). ConclusionU-shaped and V-shaped ICA siphons are more common in NAION-affected eyes; the diameter of the starting point of OA is significantly reduced.

          Release date:2022-08-16 03:23 Export PDF Favorites Scan
        • APPLICATION OF TEMPORARY BALLOON BLOCKING TECHNIQUE IN BONE TUMORS SURGERY UNDER THE AID OF CT ANGIOGRAPHY

          ObjectiveTo study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. MethodsA retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. ResultsThe CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545±0.248) cm and (1.060±0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818±1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1 800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months (mean, 21 months). According to Enneking standard, the results were excellent in 9 cases, good in 20 cases, fair in 5 cases, and poor in 2 cases at 3 months after operation. There were 10 cases of dysfunction of urination and defecation, 2 cases of tumor recurrence, and 3 cases of death after surgery. ConclusionCTA and three-dimensional reconstructions technique can accurately measure the external diameter of aortaventralis and arteria iliaca communis and the distance between low renal artery and abdominal aortic bifurcation and offer great help to choose appropriate balloon and locate the balloon during surgery. The balloon blocking technique under the assistance of CTA can obviously reduce intraoperative blood loss and tumor recurrence, supply a clear view in surgery and shorten the operation time.

          Release date: Export PDF Favorites Scan
        • Evaluation of Peripancreatic Vascular Invasion of Pancreatic Carcinoma by Multi-Slice CT Angiography

          ObjectiveTo explore the value of multi-slice CT angiography (MSCTA) in peripancreatic vascular invasion of pancreatic carcinoma. MethodsThirty-eight patients with pancreatic carcinoma were detected by MSCTA technology before operation. The peripancreatic vascular invasion of pancreatic carcinoma was evaluated by multi-planar reconstruction (MPR) and maximum intensity projection (MIP) combined with axial image, and compared with the surgical results. ResultsThe MSCTA results showed that there were 12 patients (31.6%) with vascular invasion in 38 patients with pancreatic carcinoma, and the surgical results showed that there were 16 patients (42.1%) with vascular invasion. There was a b fit goodness of two results (kappa=0.665, P=0.000). The sensibility and specificity of MSCTA was 68.8% (11/16) and 95.5% (21/22), respectively. ConclusionsMSCTA technology has a high correct rate in evaluation of peripancreatic vessel encroached by pancreatic carcinoma, the MSCTA result has a b consistency to the surgical result. It has a value of clinical application in evaluation of peripancreatic vessel encroached by pancreatic carcinoma.

          Release date:2016-09-08 10:45 Export PDF Favorites Scan
        • THREE-DIMENSIONAL VISUALIZATION RECONSTRUCTION OF MEDIAL SURAL ARTERY PERFORATOR FLAP based on Digital technology

          ObjectiveTo explore the feasibility of three-dimensional (3-D) visualization reconstruction of the medial sural artery perforator flap based on digital technology. MethodsA series of Dicom images were obtained from three healthy adult volunteers by dual source CT angiography. Then the Mimics software was used to construct the medial sural artery model and measure the indexes, including the starting position of medial sural artery, external diameters of vascular pedicle, the number of perforators, location perforated deep fascia, and the maximum pedicle length of perforators based on medial sural artery perforator flap. ResultsThe 3-D visualization reconstruction models were successfully finished with Mimics software, which can clearly display the distribution, travel, and perforating point. Thirteen perforators were found in 6 legs, which started at the popliteal artery with a mean external diameter of 2.3 mm (range, 1.9-2.7 mm). Each specimen had 1-3 perforators, which located at the site of 6.2-15.0 cm distal to popliteal crease and 2.5-4.2 cm from posterior midline. The maximum pedicle length of medial sural artery perforator flap was 10.2-13.8 cm (mean, 11.8 cm). ConclusionThe 3-D visualization reconstruction models based on digital technology can provide dynamic visualization of the anatomy of the medial sural artery for individualized design of the medial sural artery perforator flap.

          Release date: Export PDF Favorites Scan
        • APPLICATION OF COMPUTED TOMOGRAPHIC ANGIOGRAPHY IN REPAIRING SKIN DEFECT AFTER SCALP AVULSION WITH FREE LATISSIMUS DORSI FLAP TRANSPLANTATION

          Objective To investigate the clinical value of computed tomographic angiography (CTA) and three-dimensional reconstruction technique in repairing scalp avulsion wound with large skull exposure by the free latissimus dorsi flap transplantation. Methods Between October 2007 and June 2012, 9 female patients with serious scalp avulsion and large skull exposure were treated, aged 23-54 years (mean, 38 years). The injury causes included machine twist injury in 6 cases, traffic accident injury in 2 cases, and falling from height injury in 1 case. Before admission, 3 patients had scalp necrosis after scalp in situ replantation, and 6 patients underwent debridement and dressing. The time from injury to admission was 8 hours to 7 days (mean, 1 day). The avulsed scalp area ranged from 75% to 90% of the scalp area (mean, 81%); the exposed skull area ranged from 55% to 70% of the scalp area (mean, 63%). Two patients had unilateral auricle avulse. CTA was used to observe the superficial temporal artery and vein, facial artery, external jugular vein, dorsal thoracic artery and vein, and measure the blood vessel diameter before operation. According to the CTA results, the latissimus dorsal skin flaps were desinged to repair wounds in 7 cases, the latissimus dorsal muscle flaps combined with skin graft were used to repair wounds in 2 cases. According to preoperative design, operation was successfully completed in 7 cases; great saphenous vein was used as vascular graft in 2 cases having poor images of superficial temporal vessels. The size of latissimus dorsal skin flaps ranged from 20 cm × 14 cm to 25 cm × 20 cm; the donor site was repaired with skin graft. The size of latissimus dorsal muscle flaps were 23 cm × 16 cm and 16 cm × 10 cm; the donor site was directly sutured. Results The blood vessel diameter measured during operation was close to the value measured before operation. The operation time was 6-8 hours (mean, 6.5 hours). The latissimus dorsal muscle (skin) flap and skin graft survived, with primary healing of wound or incision at donor site. The patients were followed up 3 months-2 years (mean, 6 months). The flap had soft texture and skin had no ulceration. Conclusion The free latissimus dorsi flaps can repair scalp avulsion with large skull exposure. Preoperative CTA can get the vessel anatomical structure and diameter at donor and recipient sites, which will guide the operation program design and implementation so as to shorten the operation time and improve the accuracy rate of vascular anastomosis.

          Release date:2016-08-31 04:07 Export PDF Favorites Scan
        • The effect of axis pedicle and intra-axial vertebral artery on C2 pedicle screw placement

          Objective To investigate the influence of axis pedicle and intra-axial vertebral artery (IAVA) alignment on C2 pedicle screw placement by measuring the data of head and neck CT angiography. MethodsThe axis pedicle diameter (D), isthmus height (H), isthmus thickness (T), and IAVA alignment types were measured in 116 patients (232 sides) who underwent head and neck CT angiography examinations between January 2020 and June 2020. Defined the IAVA offset direction by referencing the vertical line through the center of C3 transverse foramen on the coronal scan, it was divided into lateral (L), neutral (N), and medial (M). Defined the IAVA high-riding degree by referencing the horizontal line through the outlet of the C2 transverse foramen, it was divided into below (B), within (W), and above (A). The rate of pedicle stenosis, high-riding vertebral artery, and different IAVA types were calculated, and their relationships were analysed. Simulative C2 pedicle screws were implanted by Mimics 19.0 software, and the interrelation among the rates of pedicle stenosis, high-riding vertebral artery, IAVA types, and vertebral artery injury were analyzed. ResultsThe rate of C2 pedicle stenosis was 33.6% (78/232), and the rate of high-riding vertebral artery was 35.3% (82/232). According to the offset direction and the degree of riding, IAVA was divided into 9 types, among which the N-W type (29.3%) was the most, followed by the L-W type (19.0%) and the L-B type (12.9%), accounting for 60.9%. The vertebral artery injury rate of simulative implanted C2 pedicle screws was 35.3% (82/232). The vertebral artery injury rate in patients with pedicle stenosis and high-riding vertebral artery was significantly higher than that who were not (P<0.001). The rate of pedicle stenosis, high-riding vertebral artery, and vertebral artery injury were significantly different among IAVA types (P<0.001), and M-A type was the most common. ConclusionVertebral artery injury is more common in pedicle stenosis and/or high-riding vertebral artery and/or IAVA M-A type. Preoperative head and neck CT angiography examination has clinical guiding significance.

          Release date:2022-08-04 04:33 Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜