• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "detection method" 2 results
        • Progress in hepatocyte status detection and its application in bioartificial liver support system

          Bioartificial liver support system (BALSS) provides a new way to treat liver failure and leaves more time for patients who are waiting for liver transplantation. It has detoxification function as well as the human liver, at the same time it can provide nutrition and improve the internal environment inside human body. Bioreactors and hepatocytes with good biological activity are the cores of BALSS which determine the treatment effect. However, in the course of prolonged treatment, the function and activity of hepatocytes might be greatly changed which could influence the efficacy. Therefore, it is very important to detect the status of the hepatocytes in BALSS. This paper presents some common indicators of cell activity, detoxification and synthetic functions, and also introduces the commonly detection methods corresponding to each indicator. Finally, we summarize the application of detection methods of the hepatocyte status in BALSS and discuss its development trend.

          Release date:2018-02-26 09:34 Export PDF Favorites Scan
        • "Key anatomical structure detection method" and "working length marking method" enhance the safety and efficacy of echocardiography-guided percutaneous closure of patent ductus arteriosus: A retrospective cohort study

          ObjectiveTo evaluate the impact of the "key anatomical structure detection method" and "working length marking method" on the safety and efficacy of echocardiography-guided percutaneous closure of patent ductus arteriosus (PDA). MethodsPatients who underwent echocardiography-guided percutaneous PDA closure at Fuwai Hospital, Chinese Academy of Medical Sciences, with complete clinical data, between January 2016 and December 2021, were retrospectively analyzed. Patients were divided into a study group (procedure performed using both "key anatomical structure detection method" and "working length marking method") and a control group (procedures performed without these methods). Propensity score matching (PSM) was applied for 1∶1 matching between the two groups. The primary endpoint was procedure success at 30 days after procedure. Secondary endpoints included intraoperative echocardiography localization success, major and minor complication at 6 months after procedure, and days of hospital stay. Results A total of 273 patients were included, among which 141 were in the study group and 132 in the control group. Before PSM, all patients achieved procedure success. After PSM, 77 matched pairs (154 patients) were analyzed. The study group demonstrated a significantly higher intraoperative echocardiography localization success rate (98.70% vs. 50.64%, P<0.001) and shorter hospitalization duration at (4.10±1.98) d vs. (5.01±2.16) d (P=0.007). The 6-month minor complication rate was lower in the study group (0.00% vs. 6.49%, P=0.058). All patients were successfully discharged, with no cases of device embolization, infective endocarditis, or death observed during follow-up.Conclusion "Key anatomical structure detection method" and "working length marking method" are effective echocardiography-guided adjunctive methods that enhance the safety and efficacy of PDA closure. These approaches deserve further validation in prospective multicenter studies in the future.

          Release date: Export PDF Favorites Scan
        1 pages Previous 1 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜