• <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
      <b id="1ykh9"><small id="1ykh9"></small></b>
    1. <b id="1ykh9"></b>

      1. <button id="1ykh9"></button>
        <video id="1ykh9"></video>
      2. west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Metal" 21 results
        • EXPRESSION AND ROLE OF METALLOPROTEINASES IN BREAST CANCER

          Objective To study the relationship between metalloproteinases (MMPs) and breast cancer. Methods The literature in recent years on the relationship between the expression of MMPs and breast cancer was reviewed. Results The balance between MMPs and tissue inhibitors of metalloproteinases (TIMPs) is keeping normally kept in human body. Many of the studies showed that the expression of MMPs is increased in breast cancer. Conclusion The growth, invasion and metastasis of breast cancer is closely related with the increased expression of MMPs. This suggests that MMPs is a valuable prognostic marker and TIMPs would be a novel drug against cancer.

          Release date:2016-09-08 02:01 Export PDF Favorites Scan
        • PROGRESS OF HIP RESURFACING ARTHROPLASTY

          【Abstract】 Objective To review the recent progress of hi p resurfacing arthroplasty. Methods Literatureconcerning hip resurfacing arthroplasty and current achievements was extensively and comprehensively reviewed. Results The new metal-on-metal hip resurfacing arthroplasty made much progress especially in materials and technology, and the results were satisfactory for short-term follow-up. This was increasingly widely used especially in treating young patients. But there were still some problems such as elevation of metal ions which had already aroused publ ic attention. Conclusion The new metal-onmetal hip resurfacing arthroplasty is an efficient method in the treatment of adult hip joint disease and has an encouraging future, but long-term follow-up is still needed.

          Release date:2016-09-01 09:12 Export PDF Favorites Scan
        • OBSERVATION OF EFFECTIVENESS OF HIP RESURFACING ARTHROPLASTY IN TREATMENT OF OSTEONECROSIS OF FEMORAL HEAD IN YOUNG AND MIDDLE-AGED PATIENTS

          ObjectiveTo evaluate the clinical and radiographic outcomes of hip resurfacing arthroplasty (HRA) for treating osteonecrosis of the femoral head (ONFH) in young and middle-aged patients. MethodsBetween January 2008 and April 2009, 34 patients with ONFH underwent HRA. There were 19 males and 15 females with an average age of 54 years (range, 33-59 years). Of 34 cases, 16 left hips and 18 right hips were involved, including 9 cases of alcoholinduced ONFH, 8 cases of steroid-induced ONFH, 7 cases of traumatic ONFH, and 10 cases of unexplained ONFH. According to modified Ficat classification system, 26 hips were rated as stage III, and 8 hips as stage IV. The Harris hip score (HHS) and modified University of California, Los Angeles (UCLA) activity score were used to evaluate the clinical results. Migration of prosthesis was assessed on the anteroposterior radiographs. The abduction angle was measured on the acetabular side. On the femoral side, varus-valgus shift was determined by measurement of stem-shaft angle. The axial collapse of femoral component was assessed with the component-lateral cortex ratio. ResultsHealing of incision by first intention was achieved in all patients without complications of infection and thrombosis of deep vein of lower extremities. Thirty-two patients were followed up 78 months on average (range, 70-84 months). No implant loosening, infection, femoral neck fracture, dislocation, and inflammatory pseudotumor were observed. At last follow-up, the HHS score was significantly increased to 95.22±1.47 from preoperative 50.10±2.27 (t=1.510, P=0.008). Modified UCLA activity score was significantly increased to 7.70±1.13 from preoperative 3.90±0.90 (t=0.830, P=0.003). The abduction angle, stemshaft angle, and compotent-lateral cortex ratio showed no significant difference between at 3 days after operation and last follow-up (P>0.05). ConclusionIf the indication of operation is mastered strictly, HRA may be effective in treatment for ONFH at Ficat stage III or IV in young and middle-aged patients.

          Release date: Export PDF Favorites Scan
        • EFFECTIVENESS COMPARISON BETWEEN ABSORBABLE AND METALLIC SCREWS FOR TREATMENT OF TIBIOFIBULAR SYNDESMOTIC DISRUPTIONS

          Objective To investigate the feasibility and effectiveness of absorbable screws for the treatment of tibiofibular syndesmotic disruptions by comparing with metallic screws. Methods Between July 2007 and May 2012, 69 patients with tibiofibular syndesmotic disruptions associated with ankle fractures were treated; absorbable screw fixation was used in 38 cases (group A) and metallic screw fixation was used in 31 cases (group B). There was no significant difference in gender, age, injury causes, the type of fracture, the side of fracture, and disease duration between 2 groups (P gt; 0.05). The fracture healing time, weight bearing time, and complications were recorded and compared between 2 groups. According to Baird-Jackson scoring system, the function of the ankle was assessed after 6 months. Results Infection of incision occurred in 3 cases (7.9%) of group A and 2 cases (6.5%) of group B, and skin necrosis of incision in 1 case (2.6%) of group A and 5 cases (16.1%) of group B, showing no significant difference in the incidences of infection and necrosis of incisions between 2 groups (P gt; 0.05); primary healing of incision was obtained in the other patients. The 69 cases were followed up 12-26 months (mean, 18.6 months). The weight bearing time was (2.97 ± 0.59) months in group A and was (3.16 ± 0.74 ) months in group B, showing no significant difference (t=1.175, P=0.244). X-ray films showed that fractures and tibiofibular syndesmotic disruptions healed in 2 groups; the healing time was (5.71 ± 1.01) months in group A and was (5.81 ± 1.08) months in group B, showing no significant difference (t=0.381, P=0.705). No fixation failure, breakage, or loosening occurred in 2 groups. According to Baird-Jackson scoring system, the results were excellent in 29 cases, good in 5 cases, and fair in 4 cases with an excellent and good rate of 89.5% in group A at 6 months after operation; the results were excellent in 20 cases, good in 7 cases, and fair in 4 cases with an excellent and good rate of 87.1% in group B; no significant difference was found in the excellent and good rate between 2 groups (Z= — 0.991, P=0.321). Conclusion Treatment of tibiofibular syndesmotic disruptions with absorbable screws can get good effectiveness and replace metallic screws because of avoiding additional operation for removing the screw.

          Release date:2016-08-31 10:53 Export PDF Favorites Scan
        • CORRELATION BETWEEN METALLOTHIONEIN AND PROGNOSIS IN BREAST CANCER

          To investigate the relationship between metallothionein (MT) and prognosis in breast cancer MT expression was determined with immunohistochemical method (SABC). Results: There was a statistically significant association between expression of MT in breast benign and malignant disease (P<0.005). The positive rate was 73.8%(62/84) and 15.0%(3/20) in breast cancer and mastofibroma respectively. The positivity of MT was ber in advanced clinical stages than in early clinical stages. There was no association between MT expression and lymph node metastasis. The mortality of the cancer cases with lymph node metastasis having positive MT expression was higher than those with negative MT expression. Conclusion: MT can be taken as a prognostic index of breast cancer.

          Release date:2016-08-29 09:20 Export PDF Favorites Scan
        • COMPARISON OF INTERNAL FIXATION TREATMENT OF TIBIA INTERCONDYLAR EMINENCE FRACTURE BETWEEN ABSORBABLE SCREW AND METALLIC SCREW

          Objective To compare advantage and disadvantage of internal fixation method for tibia intercondylar eminence fracture between absorbable screw and metallic screw. Methods From 1996 to 2002, 200 patients with fracture of tibia intercondylar eminence were divided into group A (with absorbable screw, n=120) andgroup B (with metallic screw, n=80). And the biological compatibility, biomechanics, bone union and complications were compared between two groups.Results There were no obvious differences in operating time and circumstance of recovery position between two groups. Group A was obviously better than group B in biological compatibility, biomechanics, bone union, joint function recovery. The average healing time of group A was three months, that of group B was three and half months. The good rates of joint function in two groups were 98.0% and 95.0% respectively. The occurrence rates of wound arthritis were 1.7% and 3.7%. There wassignificant difference between them(P<0.01). Conclusion Absorbable screw is a more ideal material of internal fixation to treat tibia intercondylar eminence fracture.

          Release date: Export PDF Favorites Scan
        • Progress in antibacterial coatings of titanium implants surfaces

          In recent years, bone implant materials such as titanium and titanium alloys have been widely used in the biomedical field due to their excellent mechanical properties and good biocompatibility. However, in clinical practice, bacterial adhesion to the material surface and postoperative infection issues may lead to implantation failure. Based on the antibacterial mechanism, this review elaborated on the antibacterial surface design of titanium implants from the aspects of anti-bacterial adhesion, contact sterilization and photocontrol sterilization. Surface modification of titanium or titanium-based alloy implants with different techniques can inhibit bacteria and promote osseointegration. Thus, the application range of multifunctional titanium-based implants in the field of orthopedics will be expanded.

          Release date:2024-04-24 09:40 Export PDF Favorites Scan
        • METAL-ON-METAL TOTAL HIP RESURFACING ARTHROPLASTY FOR TREATMENT OF ADVANCED OSTEONECROSIS OF FEMORAL HEAD IN YOUNG AND MIDDLE-AGED PATIENTS

          Objective To evaluate the short-term cl inical outcomes of metal-on-metal total hi p resurfacing arthroplasty in treating osteonecrosis of the femoral head (ONFH) in young and middle-aged patients and to compare with patients of hip osteoarthritis at the same period. Methods From July 2006 to October 2008, 33 patients (45 hips) with ONFH (ONFH group) and 39 patients (45 hips) with osteoarthritis (osteoarthritis group) were treated with metal-on-metal total hipresurfacing arthroplasty. In ONFH group, there were 18 males (27 hips) and 15 females (18 hips) with an average age of 42.7 years (range 19-58 years), including 22 left hips and 23 right hips. The causes were trauma (4 cases), glucocorticoid (25 cases), drugs (2 cases), alcohol (1 case), and psoriasis (1 case). According to Steinberg classification, there were 10 hips at stage III, 18 hips at stage IV a, 13 hips at stage IV b, and 4 hips at stage IV c. The Harris score was 52.0 ± 4.6. The disease course was 1-12 years. In osteoarthritis group, there were 26 males (30 hips) and 13 females (15 hips) with an average age of 47.1 years (range 42-65 years), including 17 left hips and 28 right hips. The causes were degenerative arthritis (23 cases), trauma (11 cases), and ankylosing spondyl itis (5 cases). The Harris score was 57.0 ± 3.8. The disease course was 3-17 years. There were no significant differences in general data between two groups (P gt; 0.05). Results All incisions achieved heal ing by first intention without compl ications of infection and thrombosis of deep vein of lower extremities. The patients were followed up for 26 months in ONFH group and 28 months in osteoarthritis group. Femoral neck fracture occurred in 1 case of osteoarthritis group after 4 months, who received total hip arthroplasty; no compl ication of prosthesis loosening, dislocation, incision infection, osteonecrosis, and bone absorption occurred in other patients. At last follow-up, the Harris scores were 93.0 ± 5.5 in ONFH group and 94.0 ± 2.4 in osteoarthritis group, showing no significant difference between two groups (P gt; 0.05); but there were significant differences between pre- and post-operation (P lt; 0.01). Conclusion The cl inical short-term outcomes ofmetal-on-metal total hip resurfacing arthroplasty to treat ONFH are satisfactory. It can achieve similar outcomes to that ofosteoarthritis group. More cases and long-term follow-up are needed to investigate long-term cl inical outcomes.

          Release date:2016-08-31 05:47 Export PDF Favorites Scan
        • MHT Scale of Adolescent with Different Gender: A Meta-analysis

          Objective To systematically evaluate and comparatively analyze the mental health status of adolescents with different genders in middle schools of China, and to provide scientific evidence for the improvement of adolescents’ mental health level. Methods Such databases as CNKI, VIP, WanFang Data, and CBM (1989 to Dec, 2009) were searched. Data were extracted from the included literature and RevMan 4.2 software was used for meta-analyses. Results Twenty-seven original literatures were included. The results of meta-analyses showed: the total anxious trend of girls was higher than that of boys (OR= –?2.14, 95%CI –?2.93 to –?1.35, Plt;0.000 01); the result of each scale displayed that girls scored higher than boys in terms of study-anxiety (OR= –?0.53, 95%CI –?0.67 to –?0. 39, Plt;0.00001), social-anxiety (OR= –?0.30, 95%CI –?0.45 to –?0.15, Plt;0.000 1), self-accusation trend (OR= –?0.30, 95%CI –?0.46 to –?0.13, Plt;0.000 6), allergy trend (OR= –?0.18, 95%CI 0.31 to –?0.05, P=0.008), body symptom (OR= –0.21, 95%CI –0.34 to –0.08, P=0.001), and phobia trend (OR= –?0.80, 95%CI –?0.91 to –?0.68, Plt;0.000 01); No significant differences were identified between boys and girls in terms of solitude trend (OR=0.09, 95%CI –?0.04 to 0.22, P=0.2) and actuation trend (OR=0.06, 95%CI –?0.15 to 0.28, P=0.56). Conclusion Targeted measures should be taken for adolescent mental health education, especially for girls.

          Release date:2016-09-07 11:02 Export PDF Favorites Scan
        • Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability

          Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.

          Release date:2025-08-19 11:47 Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

      3. <xmp id="1ykh9"><source id="1ykh9"><mark id="1ykh9"></mark></source></xmp>
          <b id="1ykh9"><small id="1ykh9"></small></b>
        1. <b id="1ykh9"></b>

          1. <button id="1ykh9"></button>
            <video id="1ykh9"></video>
          2. 射丝袜