The treatment of open reduction and internal fixation was carried out in 480 cases of fractures offemoral shafts. Patients were followed up in an average of 7. 6 years, 50 cases, rate of occurrence of10. 4%, had varying degrees of functional impairment of knee. It was considered that thecharacteristics of fractures, the time of oporation , selection of incision , the types of internal fixationdevices, and the duration of external immobilization were the main causes related to the occurren...
Objective To compare the outcomes between intramedullary nail change and augmentation plating with a retained intramedullary nail for aseptic nonunion of femoral shaft fractures after femoral nailing, and to analyze the cause so as to guide the clinical application. Methods Between June 2001 and June 2011, 28 patients with aseptic nonunion of femoral shaft fractures after femoral nailing were treated with intramedullary nail change (11 patients, group A) and augmentation plating with a retained intramedullary nail (17 patients, group B), and the clinical data were analyzed retrospectively. There was no significant difference in age, gender, smoking, location of fracture, Association for the Study of Internal Fixation (AO/ASIF) classification, type of injury, associated injury, type of nonunion, and time of nonunion between 2 groups (P gt; 0.05). The patients were followed up by imaging and the clinical function at regular intervals to observe the callus growth and the recovery condition of the affected limb function, and clinical curative effectiveness was evaluated by Tohner-Wrnch standard. Results The operation time, intraoperative bleeding volume, and intraoperative erythrocyte-transported volume in group A were significantly higher than those in group B (P lt; 0.05). There was no significant difference in postoperative drainage volume and hospitalization days between 2 groups (P gt; 0.05). All the incisions healed by first intention, and no nerve and blood vessel injury occurred. All patients were followed up 18.6 months on average (range, 12-36 months). All cases obtained bone union, and time of clinical and radiological bone healing in group B was significantly shorter than those in group A (P lt; 0.05). During follow-up, no following complication occurred: deep incision infection, injuries of blood vessels and nerves, loosening and breakage of internal fixation, loss of reduction, angulated and rotational malunion. According to Tohner-Wrnch standard at last follow-up, the results were excellent in 6 cases, good in 3 cases, and poor in 2 cases, with an excellent and good rate of 81.8% in group A; the results were excellent in 12 cases, good in 5 cases, with an excellent and good rate of 100% in group B; and difference was significant between 2 groups (Z= — 2.623, P=0.021). Conclusion Augmentation plating with a retained intramedullary nail is an ideal treatment for aseptic nonunion of femoral shaft fractures after femoral nailing and can achieve satisfactory clinical outcomes because it has simpler operation, shorter operation time, less blood loss, and less trauma than intramedullary nail change.
OBJECTIVE: To explore a method of reconstruction of hip joint function after deformed healing of the upper 1/3 of fractured femur as a complication of old fracture dislocation of hip joint. METHODS: A patient with loss of function in hip joint and fusion of knee joint was treated with lock for femur intra-medullary fixation in April 1997. RESULTS: Before operation, the diseased hip joint lost its most functions and the entire lower extremity was disabled because the knee joint had been fused. One year after operation, the follow-up examination revealed that the patient could walk by crutches without discomfort, his daily life and work recovered to normal. CONCLUSION: It is effective to treat a patient suffering old fracture-dislocation of hip joint complicated with deformed healing of the upper 1/3 of fractured femur by means of individualized artificial joint replacement and a prosthesis body with lock for femur intra-medullary fixation, and it is helpful for the development of a new clinical idea to reconstruct functions in the management of some particular cases.
Objective To explore the effectiveness of rigid interlocking nails through the tip of the greater trochanter for fixation of femur shaft fracture in adolescent. Methods A retrospective analysis was made on the clinical data of 23 adolescents with femoral shaft fractures treated between June 2011 and June 2015. Of 23 cases, 19 were male and 4 were female, aged from 13 years and 6 months to 17 years (mean, 15.2 years), weighed from 40 to 77 kg (mean, 53.5 kg). The causes were traffic accident injury in 13 cases, sports injury in 7 cases, and falling injury in 3 cases. Fracture located at the proximal 1/3 in 6 cases, middle 1/3 in 10 cases, and distal 1/3 in 7 cases; fracture was typed as transverse in 10 cases, oblique in 6 cases, spiral in 1 case, and comminuted in 6 cases. The course of disease was 3-17 days (mean, 6.2 days). At last follow-up, the leg length discrepancy, femoral neck shaft angle, femoral neck diameter, and articulotrochanteric distance (ATD) were measured on the X-ray films. Results Wounds healed in all patients, and no infection occurred. All patients were followed up 15-36 months (mean, 26.5 months). The patients had no pain and had normal gait, without lameness. The X-ray films showed bone healing at 5-13 months (mean, 6.5 months). No nonunion, delayed union, malunion of more than 5 °, or rotational deformity occurred. The removal time of internal fixations was 12-24 months (mean, 19.5 months) after operation. No heterotopic ossification, re-fracture, proximal femoral deformity, or femoral head necrosis occurred during follow-up. Two patients had early epiphyseal closure of greater trochanter, which had no impact on gait; leg-length inequality of less than 1 cm was observed in 2 cases. At last follow-up, the neck shaft angle, femoral neck diameter, and ATD of normal and affected sides were (131.7±6.3) and (132.9±7.8)°, (34.1±3.2) and (33.9±3.8) mm, and (27.8±9.2) and (26.5±8.5) mm, showing no significant difference between two sides (t=–0.24,P=0.86;t=0.18,P=0.92;t=1.03,P=0.49). Conclusion It is a reliable and effective method to use rigid interlocking nails inserted through the tip of the greater trochanter for the fixation of femur shaft fracture in adolescent.
【摘要】 目的 探討康復宣教與訓練等干預手段對股骨干骨折患者圍手術期的影響。 方法 2010年6月-2011年3月收治股骨干骨折患者90例,其中男48例,女42例;年齡17~58歲,平均38歲。開放性骨折28例,閉合性骨折62例。股骨骨折部位:上1/3骨折33例,中1/3骨折35例,下1/3骨折20例,多段骨折2例。橫形骨折20例,斜形骨折30例,粉碎性骨折40例。將90例患者隨機分為康復組(46例)和對照組(44例)。對照組采用骨科術前常規處理,康復組采用骨科術前常規處理加康復宣教與訓練。 結果 康復組住院時間為(5.35±1.27) d,對照組為(7.67±1.85) d,兩組比較差異有統計學意義(Plt;0.05)。 康復組治療后發生并發癥7例,對照組16例,康復組并發癥發生率(15.2%)明顯低于對照組(36.4%),差異有統計學意義(Plt;0.05)。治療后5 d,康復組療效獲優35例,良6例,可3例,差2例,優良率89.1%;對照組獲優25例,良5例,可12例,差2例,優良率68.2%;兩組療效比較差異有統計學意義(Plt;0.05)。 結論 康復宣教與訓練能預防與改善股骨干骨折圍手術期臥床引起的并發癥,減輕患者腿部疼痛及腫脹,縮短圍手術期時間,使患者能盡早手術,加快住院床位周轉,提高患者生活質量。【Abstract】 Objective To explore the effects of rehabilitation education and training interventions on perioperative patients with femoral shaft fractures. Methods A total of 90 patients with femoral shaft fractures were selected from June 2010 to March 2011, including 48 males and 42 females aged from 17 to 58 years (mean 38 years). In these 90 patients, open fracture was in 28 and closed fracture was in 62. Fracture site: upper 1/3 fracture was in 33, middle 1/3 fracture was in 35, lower 1/3 fracture was in 20 and multiple fractures was in 2. There were transverse fractures in 20 patients, oblique fractures in 30 patients and comminuted fractures in 40 patients. All of the patients were randomly divided into experimental group (46 patients) and control group (44 patients). The patients in the control group underwent the routine treatment before the orthopedic surgery; besides the routine treatment, the patients in the experimental group were given the rehabilitation education and training before the orthopedic surgery. Results The hospital duration in the rehabilitation group was (5.35±1.27) days while in the control group was (7.67±1.85) days, the difference was statistically significant (Plt;0.05). There were 7 cases who had complications in rehabilitation group compared with 16 patients in the control group; the incidence of the complications in the rehabilitation group (15.2%) was significantly lower than that in the control group (36.4%) (Plt;0.05). After the treatment for 5 days, the therapeutic effect in rehabilitation group were excellent in 35 cases, good in 6 cases, middle in 3 cases and poor in 2 cases (with the good rate of 89.1%); while in the control group were excellent in 25 cases, good in 5 cases, middle in 12 cases and poor in 2 cases (with the good rate of 68.2%); the difference was significant between the two groups (Plt;0.05). Conclusion Rehabilitation education and training could prevent the perioperative complications in patients with femoral shaft fracture, decrease the pain and edema, speed up the turnover of hospital beds, and improve the patients’ quality of life.
Objective To describe the design and application of a new intramedullary controlled dynamic nailing(ICDN).〓〖WTHZ〗Methods The new ICDN was made of a stainlesssteel alloy, consists of a nail shaft, innerrod, tensile screw, end cape and two interlocked screws. From December 2005 toFebruary 2007, 48 cases of femoral shaft fractures were treated with ICDN. There were 16 females and 32 males with a mean age of 36.6 years (range, 16-48years). Injury was caused by traffic accident in 26 cases, falling from a height in14, sportsrelated in 7 and crush injury in 1 case. According to Winquist classification, Thirtyseven cases were classified as typeⅠ(13 cases of typeⅠ-1,23 cases of Ⅰ-2 and 1 case of Ⅰ-3), eleven as type Ⅱ fracture ( 2 cases oftype Ⅱ-1, 8 cases of Ⅱ-2 and 1 case of Ⅱ-3). The time from injury to admission was an hour to a week. Emergency operation was performed in 19 cases and the other 29 patients were given operation within 3 days. Results All cases were followed up for an average of 5 months (3-12 months). Among them, the average healing period was 21 weeks (826 weeks) and no nonunion, delayed union and breakage of nailings occurred. The complications included 2 infections, 5 pains, and 4 deformities. Based on Johner and Wrubs standard, the results were excellent in 39 cases, good in 7 cases and fair in 2 cases, The excellent and good rate was 95.8%. Conclusions ICDN has excellent biomechanical characteristics which can provide a flexible fixation in treating femoral shaft fractures. The operation is simple and is one of the good techniquesin treating femoral shaft fractures.
There were several methods, such as free single and folded fibulae autograft, composed tissue autograft, however, it is still very difficult to repair long segment bone defect. In December 1995, we used free juxtaposed bilateral fibulae autograft to repair an 8 cm of femoral bone defect in a 4 years old child in success. The key procedure is to strip a portion of the neighboring periosteal sleeve of juxtaposed fibulae to make bare of the opposite sides of the bone shafts, suture the opposite periosteal sleeves, keep the nutrient arteries, and reconstruct the blood circulation of both fibular by anastomosis of the distal ends of one fibular artery and vein to the proximal ends of the other fibular artery and vein, and anastomosis of the proximal ends of the fibular artery and vein to lateral circumflex artery and vein. After 22 months follow up, the two shafts of juxtaposed fibulae fused into one new bone shaft. The diameter of the new bone shaft was nearly the same as the diameter of the femur. There was only one medullary cavity, and it connected to the medullary cavity of femur. This method also cold be used to repair other long segment bone defect.