WANG Zhuang 1,2,3 , WANG Fengyi 4,5,6 , WU Wenlai 1,2,3 , HUANG Shuaifei 1,2,3 , XIE Na 4,5 , ZHANG Rengang 4,5 , MA Xichao 4,5 , LI Shixin 4 , LIU Xiuyun 1,2,3 , MA Zonghao 6 , WEI Quan4 4,5 , LIU Yuan 1,2,3 , YANG Yonghong 4,5 , MING Dong 1,2,3
  • 1. Medical School, Tianjin University, Tianjin 300000, P. R. China;
  • 2. The Haihe Laboratory of Brain-Computer Interaction and Human-Machine Integration, Tianjin 300000, P. R. China;
  • 3. The State Key Laboratory of Advanced Medical Materials and Devices, Tianjin 300000, P. R. China;
  • 4. Rehabilitation Medicine Center, West China Hospital, Sichuan University, Chengdu 610041, P. R. China;
  • 5. Key Laboratory of Rehabilitation Medicine in Sichuan Province, Chengdu 610041, P. R. China;
  • 6. Department of Biomedical Engineering and Sports Technology, The Hong Kong Polytechnic University, Hong Kong 999077, P. R. China;
LIU Yuan, Email: ryanliu@tju.edu.cn; YANG Yonghong, Email: nicole@scu.edu.cn; MING Dong, Email: richardming@tju.edu.cn
Export PDF Favorites Scan Get Citation

As a promising novel rehabilitation assistive technology, non-invasive Motor Imagery Brain-Computer Interface (MI-BCI) has demonstrated significant potential in the rehabilitation of motor, sensory, and cognitive functions, as well as in prognostic assessment for stroke patients. However, the clinical application and dissemination of this technology currently face several key challenges, including unclear definition of its scope of application, lack of standardized operational procedures, insufficient standardization of rehabilitation intervention protocols, limited evidence-based medical evidence, and an incomplete efficacy evaluation system. Therefore, multidisciplinary collaboration among experts in rehabilitation medicine, neurology, engineering, artificial intelligence, and other fields are urgently needed to jointly formulate an expert consensus on the clinical application of this technology for post-stroke rehabilitation. This consensus was developed based on an evidence-based methodological framework, involving systematic retrieval of clinical research literature, evaluation of clinical evidence and quality assessment, followed by two rounds of external expert consultations and deliberations. The consensus primarily covers the scope of clinical rehabilitation applications of non-invasive MI-BCI, key technical operation points, intervention protocols, and application recommendations. The most common functional disabilities of upper and lower limb motor, sensory, cognitive and speech functions of stroke patients have been synthesized in this consensus. This consensus aims to provide systematic guidance for the clinical application of non-invasive MI-BCI technology in stroke rehabilitation and to promote its standardized development and widespread adoption.

Citation: WANG Zhuang, WANG Fengyi, WU Wenlai, HUANG Shuaifei, XIE Na, ZHANG Rengang, MA Xichao, LI Shixin, LIU Xiuyun, MA Zonghao, WEI Quan4, LIU Yuan, YANG Yonghong, MING Dong. Expert consensus on the clinical application of non-invasive motor imagery brain-computer interface technology in stroke rehabilitation. Chinese Journal of Evidence-Based Medicine, 2026, 26(10): 1126-1139. doi: 10.7507/1672-2531.202606093 Copy

Copyright ? the editorial department of Chinese Journal of Evidence-Based Medicine of West China Medical Publisher. All rights reserved

  • Previous Article

    Expert consensus on a comprehensive value assessment indicator system for hospital adoption of pulsed field ablation systems for atrial fibrillation
  • Next Article

    The effects of moderate-intensity aerobic training on balance function and prefrontal cortex connectivity in patients with acute stroke: a randomized controlled trial