Objective  To investigate the impact of bicuspid aortic valve (BAV) on the rate of ascending aortic diameter re-dilatation following ascending aortoplasty. Methods  A retrospective analysis was performed on the clinical data of patients who underwent aortic valve replacement (AVR) combined with ascending aortoplasty at Fuwai Hospital between 2010 and 2022. The rate of ascending aortic diameter re-dilatation after remodeling was calculated and compared between patients with tricuspid aortic valve (TAV) and BAV within the longitudinal aortotomy-sandwich technique and external wrapping technique groups. We explored whether BAV affects the rate of diameter re-dilatation after remodeling. Results  A total of 84 patients were included, comprising 58 males and 26 females, with a mean age of (54.30±11.36) years (range: 22-76 years). The follow-up duration for all 84 patients ranged from 18.30 to 158.83 months, with a median follow-up time of 42.82 (28.06, 103.12) months. In the longitudinal aortotomy-sandwich technique group (n=47), the rate of re-dilatation ranged from –3.08 to 5.90 mm/year, with a median rate of 0.83 (0.27, 1.44) mm/year. There was no statistical difference in the rate of ascending aortic diameter re-dilatation between patients with TAV and BAV within this group [0.65 (0.34, 1.43) mm/year vs. 0.99 (0.18, 1.44) mm/year, P=0.762]. In the external wrapping technique group (n=37), the rate of re-dilatation ranged from –3.57 to 6.61 mm/year, with a median rate of 0.35 (–0.28, 0.96) mm/year. Similarly, there was no statistical difference in the rate of ascending aortic diameter re-dilatation between patients with TAV and BAV within this group [0.33 (–0.17, 0.77) mm/year vs. 0.58 (–0.28, 1.05) mm/year, P=0.778]. Multivariate analysis revealed that age was an independent protective factor for re-dilatation after the longitudinal aortotomy-sandwich technique (P=0.019), and preoperative ascending aortic diameter was an independent risk factor for re-dilatation after the external wrapping technique (P=0.030). Conclusion BAV does not significantly affect the rate of ascending aortic diameter re-dilatation following ascending aortoplasty.

Citation: ZHOU Xiaohui. Effect of bicuspid aortic valve on re-dilatation rate after ascending aortoplasty. Chinese Journal of Clinical Thoracic and Cardiovascular Surgery, 2026, 33(9): 1457-1463. doi: 10.7507/1007-4848.202412057 Copy

Copyright ? the editorial department of Chinese Journal of Clinical Thoracic and Cardiovascular Surgery of West China Medical Publisher. All rights reserved

  • Previous Article

    Clinical efficacy of cardiovascular surgery combined with preoperative immunosuppression for Beh?et's disease: A retrospective cohort study in a single center
  • Next Article

    Efficacy and safety of single versus three-port thoracoscopic surgery for spontaneous pneumothorax: An updated systematic review and meta-analysis