• Department of Orthopaedics, the Second Affiliated Hospital of Bengbu Medical University, Bengbu Anhui, 233000, P. R. China;
NIU Guoqi, Email: ssngq@163.com
Export PDF Favorites Scan Get Citation

Objective To evaluate the screw-placement accuracy and technical advantages of patient-specific three-dimensional (3D)-printed drill guide-assisted C2 pedicle screw placement in bone models derived from patients with basilar invagination, and to provide evidence for clinical screw-placement strategies in high-risk craniocervical junction deformities. Methods Preoperative thin-slice CT data from 9 patients with basilar invagination treated between June 2016 and July 2025 were used. For each patient, two 1∶1-scale 3D-printed upper cervical spine models were fabricated, and assigned to the guide-assisted group and the freehand group by computer-generated block randomization. Bilateral C2 screws were inserted by the same spine surgeon according to a standardized protocol. In the guide-assisted group, screw placement was performed in the following sequence: guide positioning, guide pin insertion, guide removal followed by enlargement drilling, tapping, and screw insertion. In the freehand group, screw placement was performed by anatomical landmark-based localization, stepwise drilling with fluoroscopic correction, enlargement drilling and tapping, and screw insertion. The primary outcomes were postoperative CT-based Gertzbein-Robbins (GR) grading of screw position and the GR grade 0/1 acceptability rate. Secondary outcomes included entry-point deviation, axial angle deviation, and the number of fluoroscopic exposures. Results The two assessors showed good agreement in GR grading, with a Kappa coefficient>0.80, indicating reliable evaluations. Postoperative CT assessment showed that the overall distribution of GR grades was significantly better in the guide-assisted group than in the freehand group (P<0.05). The GR grade 0/1 acceptability rate was higher in the guide-assisted group, but the difference was not significant (P>0.05). Entry-point deviation, axial angle deviation, and the number of fluoroscopic exposures were all significantly lower in the guide-assisted group than in the freehand group (P<0.05). Conclusion Patient-specific 3D-printed drill guides can reduce geometric deviations in C2 pedicle screw placement in basilar invagination and decrease the number of fluoroscopic exposures. They show a potential advantage in improving the GR grade 0/1 acceptability rate; however, further clinical studies with larger samples are needed for verification.

Citation: LI Jinhu, JIANG Weili, CHENG Jiawei, NIU Chong, SI Wenshuo, NIU Guoqi. Experimental study of patient-specific three-dimensional-printed drill guide-assisted C2 pedicle screw placement in models derived from patients with basilar invagination. Chinese Journal of Reparative and Reconstructive Surgery, 2026, 40(5): 723-730. doi: 10.7507/1002-1892.202511085 Copy

Copyright ? the editorial department of Chinese Journal of Reparative and Reconstructive Surgery of West China Medical Publisher. All rights reserved

  • Previous Article

    Radiological characteristics and associated factors of single-level cervical disc herniation combining with focal ossification of posterior longitudinal ligament
  • Next Article

    Short-term effectiveness of visual treatment solution-assisted treatment for Crowe type - developmental dysplasia of the hip